Check GUIALLOWED before calling Window #213

Closed
7 tasks
LFlamme opened this issue Jul 26, 2018 · 2 comments
Closed
7 tasks

Check GUIALLOWED before calling Window #213

LFlamme opened this issue Jul 26, 2018 · 2 comments

Comments

@LFlamme
Copy link

LFlamme commented Jul 26, 2018

Hi,

We need to have some checks of GUIALLOWED before window ist called, else NAS will run on an Error.

Objects we discovered need a change:

  • Codeunit 23 Item Jnl.- Post Batch

image
image
image
image
image
image

  • Codeunit 80 Sales Post

image
image
image
image
image
image
image
image
image

  • Codeunit 5407 Prod. Order Status Management

image
image

  • Codeunit 99000831 Reservation Engine Mgt.

image

  • Report 299 Delete Invoiced Sales Orders

image

  • Report 499 Delete Invoiced Purch. Orders

image

  • Report 5706 Create Stockkeeping Unit

image
image
image
image

Thanks in advance

@rdebath
Copy link

rdebath commented Aug 22, 2018

This hasn't been true since version 7, (maybe 6 RTC) the dialog type does NOT error in a background RTC session.

Obviously the input routines still do (CONFIRM and STRMENU)

@StanislawStempin StanislawStempin transferred this issue from microsoft/AL Nov 1, 2018
@JesperSchulz
Copy link
Contributor

This issue has been resolved! Thanks for reporting!