bash
The hosted component allows Sming's host emulator to run parts of the commands on an actual microcontroller. The communication is done via simplePRC and the microcontroller has to be flashed with a special application.
Sming's host emulator allows easier debugging and development of embedded applications. This component named "Hosted" extends the host emulator and facilitates testing functionality that only a real microcontroller can provide as for example digital I/O operations or SPI operations.
For example in order to run the Basic_Blink application under the host emulator and run the actual blinking of a LED on a microcontroller we can compile the application using the following directives:
make SMING_ARCH=Host ENABLE_HOSTED=tcp HOSTED_SERVER_IP=192.168.4.1
SMING_ARCH=Host
instructs the build system to build the application for the Host architecture.ENABLE_HOSTED=tcp
instructs the host emulator to communicate with the real microcontroller using TCP.HOSTED_SERVER_IP=192.168.4.1
tells the host emulator where the server is running.
We need to compile and flash also a special application on the desired microcontroller. This application will act as an RPC Server and will execute the commands from the host emulator on the microcontroller.
In the samples
directory you will find the sample applications that will turn your microcontroller into an RCP server.
The compilation and flashing for ESP32, for example, can be done using the following commands:
cd samples/tcp
make SMING_ARCH=Esp32 WIFI_SSID=YourSSID WIFI_PWD=YourPassword
make flash
If you replace SMING_ARCH=Esp32
with SMING_ARCH=Esp8266
then the hosted application will be compiled and flashed on a ESP8266 microcontroller. Make sure to replace the values of WIFI_SSID and WIFI_PWD with the actual name and password for the Access Point (AP).
At the moment the communication between an application running on the Host and the RCP server running on a microcontroller can be done using TCP or serial interface.
The transport
classes are located under include/Hosted/Transport
.
ENABLE_HOSTED
Default: empty (disabled)
Enables the hosted component. Valid values for the moment are: - tcp
for communication over TCP network. - serial
for communication over serial interface
HOSTED_SERVER_IP
Default: 192.168.13.1
Used only when ENABLE_HOSTED=tcp is specified. Specifies the IP address of the remote RPC server.
HOSTED_COM_PORT
Default: COM_PORT
Used only when ENABLE_HOSTED=serial is specified. Specifies which local communication port should be used to connect to the remote RPC server.
HOSTED_COM_SPEED
Default: 115200
Used only when ENABLE_HOSTED=serial is specified. Specifies the communication baud rate.