Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

FundamentalWave: orientation of rotor currents #1226

Closed
modelica-trac-importer opened this issue Jan 14, 2017 · 6 comments
Closed

FundamentalWave: orientation of rotor currents #1226

modelica-trac-importer opened this issue Jan 14, 2017 · 6 comments
Assignees
Labels
bug Critical/severe issue L: Magnetic.FundamentalWave Issue addresses Modelica.Magnetic.FundamentalWave P: highest Highest priority issue
Milestone

Comments

@modelica-trac-importer
Copy link

Reported by ahaumer on 30 Jul 2013 09:15 UTC
The orientation of rotor currents is wrong:
AIMC.rotorCage, AIMS.rotor, SMxx.rotorCage
Should be fixed together with #1223.
Should be fixed for MSL 3.2, too.


Migrated-From: https://trac.modelica.org/Modelica/ticket/1226

@modelica-trac-importer modelica-trac-importer added this to the MSL3.2.1 milestone Jan 14, 2017
@modelica-trac-importer modelica-trac-importer added bug Critical/severe issue L: Magnetic.FundamentalWave Issue addresses Modelica.Magnetic.FundamentalWave P: highest Highest priority issue labels Jan 14, 2017
@modelica-trac-importer
Copy link
Author

Comment by christiankral on 30 Jul 2013 11:00 UTC
Bug fixed for Machines and FundamentalWave library in MSL 3.2.1 in 9491140.

@modelica-trac-importer
Copy link
Author

Comment by christiankral on 30 Jul 2013 11:27 UTC
Fixed problem for MSL 3.2 in 979ede3.

@modelica-trac-importer
Copy link
Author

Modified by christiankral on 30 Jul 2013 11:27 UTC

@modelica-trac-importer
Copy link
Author

Comment by christiankral on 21 Jul 2014 18:57 UTC
There are still issues open:

The rotor currents

  • ir
  • rotorCage.i
    of the induction and synchronous machines are NOT equal but shall be equal. This is a bug and shall be corrected.

@modelica-trac-importer
Copy link
Author

Changelog modified by christiankral on 21 Jul 2014 18:57 UTC
Fixed wrong signs of rotor currents of all cage models

@modelica-trac-importer
Copy link
Author

Comment by christiankral on 21 Jul 2014 20:46 UTC
Unification of implementations with correct signs of all rotor currents. This applies to induction and synchronous machines. Changes have been applied to the transient and the quasi static FundamentalWave library. A backwards compatible alias variable has been added for the rotor currents of the squirrel cage model of the Machines library.

The applied changes 9bbd031 in the transient and quasi static FundamentalWave packages are bug fixes.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
bug Critical/severe issue L: Magnetic.FundamentalWave Issue addresses Modelica.Magnetic.FundamentalWave P: highest Highest priority issue
Projects
None yet
Development

No branches or pull requests

5 participants