Propagation of wrong operational temperature to resistances #2328
Labels
bug
Critical/severe issue
L: Magnetic.FundamentalWave
Issue addresses Modelica.Magnetic.FundamentalWave
L: Magnetic.QuasiStatic
Issue addresses Modelica.Magnetic.QuasiStatic
Milestone
In #2318 @beutlich pointed out that the parameter TOperational is not used in some models. A closer investigation shows that there is a bug in the propagating of TRef instead of TOperational as operating temperature to the resistor models of some components of electric machines. This issue refers to the following models:
Yet all machine models work OK without issues, as the heat ports of all resistors are always used and the operating temperatures are provided through ambient models which use the right operating temperatures, in case the heat port of the machine is not used.
The text was updated successfully, but these errors were encountered: