Renogy Client

Java app which communicate with Renogy Rover 40A over a RS232 serial port, using the Rover Modbus protocol. Works for all Renogy Rovers, including rebranded ones (e.g. Biltema MPPT controller).

Licensed under the MIT license.

Intended use

Intended to be running on a Raspberry PI. The Raspberry PI needs to be connected over USB/RS232 adapter to a RS232/RJ12 port of Renogy Rover. This program will periodically show the newest data on screen, or optionally append the newest data to a CSV file, which you can inspect to see the performance of your solar array.

For exact instructions on how to connect Renogy Rover RS232/RJ12 over an USB adapter to your Raspberry PI, please see NodeRenogy.

You can use Grafana and the postgresql plugin to read the postgresql log database and show charging data in charts:

Grafana Screenshot

Help

Run:

$ ./bin/renogy-klient -h

Usage: renogy-klient options_list
Arguments: 
    device -> the file name of the serial device to communicate with, e.g. /dev/ttyUSB0 . Pass in `dummy` for a dummy Renogy client { String }
Options: 
    --status -> print the Renogy Rover status as JSON to stdout and quit 
    --utc -> CSV: dump date in UTC instead of local, handy for Grafana 
    --csv -> appends status to a CSV file, disables stdout status logging { String }
    --postgres -> appends status to a postgresql database, disables stdout status logging. Accepts the connection url, e.g. jdbc:postgresql://localhost:5432/postgres { String }
    --pguser -> PostgreSQL user name { String }
    --pgpass -> PostgreSQL password { String }
    --statefile -> overwrites status to file other than the default 'status.json' { String }
    --pollinterval, -i -> in seconds: how frequently to poll the controller for data, defaults to 10 { Int }
    --prunelog -> prunes log entries older than x days, defaults to 365 { Int }
    --verbose -> Print verbosely what I'm doing 
    --help, -h -> Usage info

Downloading

Read below on how to compile the project from sources.

This program requires Java JRE 17+ to run:

$ sudo apt install openjdk-20-jre-headless

Running

Renogy-Klient runs on x86, x86-64, arm32, arm64, risc-v, basically everywhere where Java JRE runs. Beware though: Grafana doesn't support RISC-V yet; please see+vote for Discussion #69332.

Example which will log dummy data periodically into a CSV file:

$ ./renogy-klient --csv log.csv dummy

To connect to an actual device, pass in the device file name of tty connected to the Renogy, e.g.

$ ./renogy-klient /dev/ttyUSB0 --status

The --status flag will cause the app to connect to the device, print its status and quit. To continuously poll the device for data, run

$ ./renogy-klient --csv log.csv /dev/ttyUSB0

The program will overwrite status.json file with the new data polled from the device; the program will also start appending the information to a CSV file so that you have historic data.

The status JSON example:

{
    "systemInfo": {
        "maxVoltage": 24,
        "ratedChargingCurrent": 40,
        "ratedDischargingCurrent": 40,
        "productType": "Controller",
        "productModel": "RENOGY ROVER",
        "softwareVersion": "v1.2.3",
        "hardwareVersion": "v4.5.6",
        "serialNumber": "1501FFFF"
    },
    "powerStatus": {
        "batterySOC": 100,
        "batteryVoltage": 25.6,
        "chargingCurrentToBattery": 2.3,
        "batteryTemp": 23,
        "controllerTemp": 23,
        "loadVoltage": 0.0,
        "loadCurrent": 0.0,
        "loadPower": 0,
        "solarPanelVoltage": 60.2,
        "solarPanelCurrent": 4.2,
        "solarPanelPower": 252
    },
    "dailyStats": {
        "batteryMinVoltage": 25.0,
        "batteryMaxVoltage": 28.0,
        "maxChargingCurrent": 10.0,
        "maxDischargingCurrent": 10.0,
        "maxChargingPower": 240,
        "maxDischargingPower": 240,
        "chargingAh": 100,
        "dischargingAh": 100,
        "powerGenerationWh": 0,
        "powerConsumptionWh": 0
    },
    "historicalData": {
        "daysUp": 20,
        "batteryOverDischargeCount": 1,
        "batteryFullChargeCount": 20,
        "totalChargingBatteryAH": 2000,
        "totalDischargingBatteryAH": 2000,
        "cumulativePowerGenerationWH": 2000,
        "cumulativePowerConsumptionWH": 2000
    },
    "status": {
        "streetLightOn": false,
        "streetLightBrightness": 0,
        "chargingState": "MpptChargingMode",
        "faults": [
            "ControllerTemperatureTooHigh"
        ]
    }
}

The CSV file contains the same fields, in a tabular form:

"DateTime","BatterySOC","BatteryVoltage","ChargingCurrentToBattery","BatteryTemp","ControllerTemp","SolarPanelVoltage","SolarPanelCurrent","SolarPanelPower","Daily.BatteryMinVoltage","Daily.BatteryMaxVoltage","Daily.MaxChargingCurrent","Daily.MaxChargingPower","Daily.ChargingAmpHours","Daily.PowerGeneration","Stats.DaysUp","Stats.BatteryOverDischargeCount","Stats.BatteryFullChargeCount","Stats.TotalChargingBatteryAH","Stats.CumulativePowerGenerationWH","ChargingState","Faults"
"2022-09-19T13:48:53Z",73,24.19,4.23,23,18,42.04,2.44,102,24.19,24.19,4.23,102,0.00,0.00,1,0,0,0,0.00,"MpptChargingMode",""
"2022-09-19T13:49:03Z",93,28.11,4.76,21,21,56.71,2.36,133,24.19,28.11,4.76,133,0.01,0.37,1,0,0,0,0.37,"MpptChargingMode",""

You can install Grafana and the Grafana CSV plugin, to visualize the CSV file as a nice set of charts.

WARNING: CSV file will get big over time: 0,5mb logged per day, 180mb file over a year. Grafana WILL spend lots of CPU to parse the CSV file. Only use CSV for initial testing; don't use for regular use. Use postgresql instead.

The memory usage is not that bad: With 64bit Java, the memory usage starts at 80mb, climbs up to 100mb, but goes down to 51mb after a day or so. With 32bit java, the numbers are much better: the usage starts at 55mb and goes down to 25mb after a day, and even 10mb after two days (!!). Probably part of JVM is swapped out: I've created a 512mb swap on my 32bit Ubuntu on RPI Zero 2W.

PostgreSQL

The CSV file tends to grow quite quickly. If you intend to use this tool with Grafana, it's far better to output the data to a proper database. PostgreSQL is awesome: it consumes roughly 30mb of memory and offers blazing-fast queries. Use this if you intend to use this tool with Grafana.

To install the database quickly on your Raspberry PI, run the following:

sudo apt install postgresql
sudo -u postgres psql
postgres=# create database mydb;
postgres=# create user myuser with encrypted password 'mypass';
postgres=# grant all privileges on database mydb to myuser;
postgres=# GRANT ALL ON SCHEMA public TO myuser;
postgres=# \q

Then:

$ ./renogy-klient --postgres postgresql://localhost:5432/mydb --pguser myuser --pgpass mypass /dev/ttyUSB0

The following columns are available in the log database table:

Column Type Meaning
DateTime integer unix timestamp: a number of seconds since the Epoch 00:00:00 UTC on 1 January 1970.
BatterySOC integer Current battery capacity value (state of charge), 0..100%
BatteryVoltage real battery voltage in V
ChargingCurrentToBattery real charging current (to battery), A
BatteryTemp int battery temperature in °C
ControllerTemp int controller temperature in °C
SolarPanelVoltage real solar panel voltage, in V. Precision: 1 decimal points.
SolarPanelCurrent real Solar panel current (to controller), in A. Precision: 2 decimal points.
SolarPanelPower int charging power, in W
Daily_BatteryMinVoltage real Battery's min. voltage of the current day, V. Precision: 1 decimal points.
Daily_BatteryMaxVoltage real Battery's max. voltage of the current day, V. Precision: 1 decimal points.
Daily_MaxChargingCurrent real Max. charging current of the current day, A. Probably applies to controller only. Precision: 2 decimal points.
Daily_MaxChargingPower int Max. charging power of the current day, W. Probably applies to controller only.
Daily_ChargingAmpHours int Charging amp-hrs of the current day, AH.probably only applies to controller; will be 0 for inverter.
Daily_PowerGeneration int Power generation of the current day, WH.
Stats_DaysUp int Total number of operating days
Stats_BatteryOverDischargeCount int Total number of battery over-discharges
Stats_BatteryFullChargeCount int Total number of battery full-charges.
Stats_TotalChargingBatteryAH int Total charging amp-hrs of the battery.
Stats_CumulativePowerGenerationWH int cumulative power generation in Wh. Probably only applies to controller, will be 0 for inverter.
ChargingState int Charging status, see below
Faults text Comma-separated list of faults

The DateTime column is an unix timestamp: a number of seconds since the Epoch 00:00:00 UTC on 1 January 1970. It's directly compatible with the official PostgreSQL Grafana plugin.

Values for the ChargingState column:

Value Constant Meaning
0 ChargingDeactivated Charging is deactivated. There is no current/voltage detected from the solar panels. This happens when it's night outside, or the solar array is disconnected: either the fuse tripped, or perhaps the cables are broken.
1 ChargingActivated ?
2 MpptChargingMode Bulk Charging. This algorithm is used for day to day charging. It uses 100% of available solar power to recharge the battery and is equivalent to constant current. In this stage the battery voltage has not yet reached constant voltage (Equalize or Boost), the controller operates in constant current mode, delivering its maximum current to the batteries (MPPT Charging). Also called Bulk Charging.
3 EqualizingChargingMode Equalization: Is carried out every 28 days of the month. It is intentional overcharging of the battery for a controlled period of time. Certain types of batteries benefit from periodic equalizing charge, which can stir the electrolyte, balance battery voltage and complete chemical reaction. Equalizing charge increases the battery voltage, higher than the standard complement voltage, which gasifies the battery electrolyte. Should not be used for AGM batteries.
4 BoostChargingMode Constant Charging Mode. When the battery reaches the constant voltage set point, the controller will start to operate in constant charging mode, where it is no longer MPPT charging. The current will drop gradually. This has two stages, equalize and boost and they are not carried out constantly in a full charge process to avoid too much gas precipitation or overheating of the battery. See EqualizingChargingMode for more details. Boost stage maintains a charge for 2 hours by default. The user can adjust the constant time and preset value of boost per their demand.
5 FloatingChargingMode After the constant voltage stage (BoostChargingMode/EqualizingChargingMode), the controller will reduce the battery voltage to a float voltage set point. Once the battery is fully charged, there will be no more chemical reactions and all the charge current would turn into heat or gas. Because of this, the charge controller will reduce the voltage charge to smaller quantity, while lightly charging the battery. The purpose for this is to offset the power consumption while maintaining a full battery storage capacity. In the event that a load drawn from the battery exceeds the charge current, the controller will no longer be able to maintain the battery to a Float set point and the controller will end the float charge stage and refer back to bulk charging (MpptChargingMode).
6 CurrentLimiting Overpower

InfluxDB 2

InfluxDB 2 is also supported. It's a time-based database, and therefore a perfect fit for our purposes. It offers blazing-fast queries and also offer charting capabilities. Yet I'd still recommend to go with Grafana since Grafana charting capabilities are on a much better level. Also, InfluxDB2 consumes up to 100mb of RAM.

Run InfluxDB2 easily in docker:

mkdir db
docker run --rm -ti -p 8086:8086 \
	-v ./db:/var/lib/influxdb2 \
	-e DOCKER_INFLUXDB_INIT_MODE=setup \
	-e DOCKER_INFLUXDB_INIT_USERNAME=admin \
	-e DOCKER_INFLUXDB_INIT_PASSWORD=mysecretpassword \
	-e DOCKER_INFLUXDB_INIT_ORG=my_org \
	-e DOCKER_INFLUXDB_INIT_BUCKET=solar \
	influxdb:2.7.1

In order to create a token, head to localhost:8086, then to "Load Data", "API Tokens", generate the all-access API token and write it down; it looks like this: 6SCVEHn-2P8L2VBeBf_al_hLPldD-yjypErsi8SW-4aaT4KPOiaubwS7RwRVRTMazquTd7rmeeE1DsEZeFR64g==.

Now you can configure InfluxDB2 to accept this access token:

docker run --rm -ti -p 8086:8086 \
	-v ./db:/var/lib/influxdb2 \
	-e DOCKER_INFLUXDB_INIT_MODE=setup \
	-e DOCKER_INFLUXDB_INIT_USERNAME=admin \
	-e DOCKER_INFLUXDB_INIT_PASSWORD=mysecretpassword \
	-e DOCKER_INFLUXDB_INIT_ORG=my_org \
	-e DOCKER_INFLUXDB_INIT_BUCKET=solar \
	-e DOCKER_INFLUXDB_INIT_ADMIN_TOKEN="6SCVEHn-2P8L2VBeBf_al_hLPldD-yjypErsi8SW-4aaT4KPOiaubwS7RwRVRTMazquTd7rmeeE1DsEZeFR64g==" \
	influxdb:2.7.1

See the influxdb Docker Hub documentation for more details.

Now you can run the renogy-klient:

$ ./renogy-klient --influx http://localhost:8086 --influxorg my_org --influxbucket solar --influxtoken "token" /dev/ttyUSB0

Dummy Renogy Device

Use dummy instead of the device name. This will create a dummy renogy device and poll data off it:

$ ./renogy-klient dummy

Faults

Table of possible faults:

Fault Meaning
ChargeMOSShortCircuit
AntiReverseMOSShort
SolarPanelReverselyConnected PV Reverse Polarity. The controller will not operate if the PV wires are switched. Wire them correctly to resume normal controller operation.
SolarPanelWorkingPointOverVoltage
SolarPanelCounterCurrent
PhotovoltaicInputSideOverVoltage PV Overvoltage. If the PV voltage is larger than maximum input open voltage 100VDC. PV will remain disconnected until the voltage drops below 100VDC
PhotovoltaicInputSideShortCircuit PV Array Short Circuit. When PV short circuit occurs, the controller will stop charging. Clear it to resume normal operation.
PhotovoltaicInputOverpower PV Overcurrent. The controller will limit the battery chgarging current to the maximum battery current rating. Therefore, an over-sized solar array will not operate at peak power.
AmbientTemperatureTooHigh
ControllerTemperatureTooHigh Over-Temperature. If the temperature of the controller heat sink exceeds 65 C, the controller will automatically start reducing the charging current. The controller will shut down when the temperature exceeds 85 C.
LoadOverpowerOrLoadOverCurrent Load Overload. If the current exceeds the maximum load current rating 1.05 times, the controller will disconnect the load. Overloading must be cleared up by reducing the load and restarting the controller.
LoadShortCircuit Load Short Circuit. Fully protected against the load wiring short-circuit. Once the load short (more than quadruple rate current), the load short protection will start automatically. After 5 automatic load reconnect attempts, the faults must be cleared by restarting the controller.
BatteryUnderVoltageWarning
BatteryOverVoltage
BatteryOverDischarge

Grafana

Follow the Install Grafana from APT Repository tutorial to install Grafana on your arm32/arm64 machine and have it update automatically. To enable and start after the installation, read Start Grafana.

Login to Grafana with admin/admin and change the password. Then, go to Home / Connections / Add new connection and add a PostgreSQL datasource, with the following values:

  • Name: PostgreSQL
  • Host: localhost:5432
  • Database: mydb
  • User: myuser
  • Pass: mypass
  • TLS/SSL Mode: disable

Edit /etc/grafana/grafana.ini and enable anonymous access to Grafana. This way, you will not have to enter username/password every time you want to see the dashboard. To apply the settings, restart Grafana:

sudo systemctl restart grafana-server

TODO example dashboards

Compiling From Sources

You can try to compile the project on your Raspberry PI directly, or you can compile the project on your more powerful device, then scp the zip file to RPI.

  1. Install Java JDK sudo apt install openjdk-20-jdk-headless. JRE is enough to run the app, but you need JDK to build it.
  2. git clone https://github.com/mvysny/renogy-klient/ and cd renogy-klient
  3. Build with ./gradlew -x test
  4. Find the zip file in build/distributions/renogy-klient.zip
  5. (Optional) scp the file to RPI: scp renogy-klient.zip ubuntu@rpi.local:/home/ubuntu/work/

More documentation

About

Renogy Rover client in JVM/Kotlin