Skip to content

Improper Restriction in NI MeasurementLink Python Services

High
bkeryan published GHSA-3f48-9j7q-q2gv Oct 5, 2023

Package

pip ni-measurementlink-service (pip)

Affected versions

<1.1.1
>=1.2.0-dev0, <1.2.0

Patched versions

1.1.1
1.2.0

Description

Impact

An improper access restriction in NI MeasurementLink Python services could allow an attacker on an adjacent network to reach services exposed on localhost. These services were previously thought to be unreachable outside of the node. This affects measurement plug-ins written in Python using version 1.1.0 of the ni-measurementlink-service Python package and all previous versions.

Patches

Upgrade all Python measurement plug-ins to use ni-measurementlink-service version 1.1.1 or later.

References

Visit ni.com/info and enter the info code cve-2023-4570 for more information.

Severity

High
8.8
/ 10

CVSS base metrics

Attack vector
Adjacent
Attack complexity
Low
Privileges required
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

CVE ID

CVE-2023-4570

Weaknesses