/
reports-spec.yml
executable file
·103 lines (103 loc) · 5.96 KB
/
reports-spec.yml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
package: dmriprep
sections:
- name: Summary
reportlets:
- bids: {datatype: figures, desc: summary, suffix: T1w}
- name: Anatomical
reportlets:
- bids:
datatype: figures
desc: conform
extension: [.html]
suffix: T1w
- bids: {datatype: figures, suffix: dseg}
caption: This panel shows the template T1-weighted image (if several T1w images
were found), with contours delineating the detected brain mask and brain tissue
segmentations.
subtitle: Brain mask and brain tissue segmentation of the T1w
- bids: {datatype: figures, space: .*, suffix: T1w, regex_search: True}
caption: Spatial normalization of the T1w image to the <code>{space}</code> template.
description: Results of nonlinear alignment of the T1w reference one or more template
space(s). Hover on the panels with the mouse pointer to transition between both
spaces.
static: false
subtitle: Spatial normalization of the anatomical T1w reference
- bids: {datatype: figures, desc: reconall, suffix: T1w}
caption: Surfaces (white and pial) reconstructed with FreeSurfer (<code>recon-all</code>)
overlaid on the participant's T1w template.
subtitle: Surface reconstruction
- name: Fieldmaps
ordering: session,run,fmapid
reportlets:
- bids: {datatype: figures, desc: mapped, suffix: fieldmap}
caption: Inhomogeneities of the <em>B<sub>0</sub></em> field introduce (oftentimes severe) spatial distortions
along the phase-encoding direction of the image. Some scanners produce a <em>B<sub>0</sub></em>
mapping of the field, using Spiral Echo Imaging (SEI) or postprocessing a "phase-difference"
acquisition. The plot below shows an anatomical "magnitude" reference and the corresponding
fieldmap.
description: Hover over the panels with the mouse pointer to also visualize the intensity of the
field inhomogeneity in Hertz.
static: false
subtitle: "Susceptibility-derived Distortion Correction (SDC): field inhomogeneity estimation"
- bids: {datatype: figures, desc: phasediff, suffix: fieldmap}
caption: Inhomogeneities of the <em>B<sub>0</sub></em> field introduce (oftentimes severe) spatial distortions
along the phase-encoding direction of the image. A Gradient-Recalled Echo (GRE) scheme for the
mapping of the <em>B<sub>0</sub></em> inhomogeneities by subtracting the phase maps obtained at
two subsequent echoes. The plot below shows an anatomical "magnitude" reference and the corresponding
fieldmap.
description: Hover over the panels with the mouse pointer to also visualize the intensity of the
field inhomogeneity in Hertz.
static: false
subtitle: "Susceptibility-derived Distortion Correction (SDC): field inhomogeneity estimation"
- bids: {datatype: figures, desc: pepolar, suffix: fieldmap}
caption: Inhomogeneities of the <em>B<sub>0</sub></em> field introduce (oftentimes severe) spatial distortions
along the phase-encoding direction of the image. Utilizing two or more images with different
phase-encoding polarities (PEPolar) or directions, it is possible to estimate the inhomogeneity
of the field. The plot below shows a reference EPI (echo-planar imaging) volume generated
using two or more EPI images with varying phase-encoding blips.
description: Hover on the panels with the mouse pointer to also visualize the intensity of the
inhomogeneity of the field in Hertz.
static: false
subtitle: "Susceptibility-derived Distortion Correction (SDC): field inhomogeneity estimation"
- name: Diffusion
ordering: session,acquisition,run
reportlets:
- bids: {datatype: figures, desc: validation, suffix: dwi}
- bids: {datatype: figures, desc: brain, suffix: mask}
caption: Average <em>b=0</em> that serves for reference in early preprocessing steps.
descriptions: The reference <em>b=0</em> is obtained as the voxel-wise median across
all <em>b=0</em> found in the dataset, after accounting for signal drift.
The red contour shows the brain mask calculated using this reference <em>b=0</em>.
subtitle: Reference <em>b=0</em> and brain mask
- bids: {datatype: figures, desc: sdc, suffix: dwi}
caption: Susceptibility distortions correction (SDC).
description: The reportlet shows a <em>b=0</em> reference <em>before</em> and <em>after</em> distortion correction.
static: false
subtitle: Unwarping of susceptibility distortions
- bids: {datatype: figures, desc: eddy, suffix: dwi}
caption: Head-motion and eddy current corrected diffusion data
description: Eddy current-induced geometric distortions and head-motion
realignment parameters were estimated with the joint modeling of
<code>eddy_openmp</code>, included in FSL.
static: false
subtitle: Eddy corrected diffusion data
- bids: {datatype: figures, desc: coreg, suffix: dwi}
caption: Diffusion-weighted data and anatomical data (EPI-space and T1w-space)
were aligned with <code>mri_coreg</code> (FreeSurfer).
WARNING - <code>bbregister</code> refinement rejected.
description: Note that nearest-neighbor interpolation is used in this reportlet
in order to highlight potential slice Inhomogeneities and other artifacts, whereas
the final images are resampled using cubic B-Spline interpolation.
static: false
subtitle: Alignment of diffusion anatomical MRI data (volume based)
- bids: {datatype: figures, desc: bbregister, suffix: dwi}
caption: Diffusion-weighted data and anatomical data (EPI-space and T1w-space)
were aligned with <code>bbregister</code> (FreeSurfer).
description: Note that nearest-neighbor interpolation is used in this reportlet
in order to highlight potential slice Inhomogeneities and other artifacts, whereas
the final images are resampled using cubic B-Spline interpolation.
static: false
subtitle: Alignment of diffusion and anatomical MRI data (surface driven)
- name: About
reportlets:
- bids: {datatype: figures, desc: about, suffix: T1w}