Targeted at the Tesla Wall Connector Gen 3. Only provides read access to API data (write isn't supported by the API).
Installation is facilitated via the ioBroker web interface and the configuration will auto-open once installation is completed.
In addition to the adapter installation you have to add an instance of the adapter.
Field | Description |
---|---|
Tesla Wall Connector Gen 3 | Type in the IP-address of your Tesla Wall Connector Gen 3 (FQDN is also possible if you have a working local DNS). |
Polling Interval | You can change the polling interval for high priority data (how often the Adapter reads from your Tesla Wall Connector Gen 3), too. (Default: 10 seconds) |
Request-Timeout | If your network requires a higher timeout for requests sent to Tesla Wall Connector Gen 3, please change the Request-Timeout in miliseconds accordingly. (Default: 5000 miliseconds) |
Polling Retries | In case there is an issue communicating with Tesla Wall Connector Gen 3 the adapter will retry several times. You can adjust how often it will try to read from Tesla Wall Connector Gen 3. (Default: 10) |
This does not apply to Adapter Start - if the System is unavailable to Adapter will stop. | |
Polling Retry Factor | To space retries apart a bit more you can adjust the Polling Retry Factor. (Default: 2) - Example: Using default settings the 1st retry will happen 20 seconds after the initial try, the 2nd will happen 40 seconds after the 2nd try. After each successful connect to SENEC, the number of retries is reset. |
Once finished setting up configuration, hit SAVE AND CLOSE
to leave configuration dialogue. The adapter will automatically restart.
Here you can find a description of the states and how to use them. All states of this adapter are read-only states.
Please be aware that most (if not all) descriptions might be way off and might require confirmation or corrections. Pull-Requests with updates are welcome and encouraged!
-
info.connection
Data type Permission boolean R Read-only boolean which is true if the adapter is connected to the Tesla Wall Connector Gen 3.
-
alert_count
Data type Permission number R Read-only number, representing the number of alerts.
-
avg_startup_temp
Data type Permission number R Read-only number, representing if the average startup temperature.
-
charge_starts
Data type Permission number R Read-only string, representing the number of charging starts.
-
charging_time_s
Data type Permission number R Read-only number, representing the charging time in seconds of the WC3
-
connector_cycles
Data type Permission number R Read-only number, representing the number of connector cycles (plugging in and out most likely counting each as 1).
-
contactor_cycles
Data type Permission number R Read-only number, representing the number of state-changes of the relais so far.
-
contactor_cycles_loaded
Data type Permission number R Read-only number, representing the number of charging cycles.
-
energy_wh
Data type Permission number R Read-only number, representing the amount of energy supplied in Wh.
-
thermal_foldbacks
Data type Permission number R Read-only number, representing the ???
-
uptime_s
Data type Permission number R Read-only number, representing the uptime in seconds of the WC3
-
firmware_version
Data type Permission string R Firmware version on the Tesla Wall Connector Gen 3
-
part_number
Data type Permission string R Part number of the Tesla Wall Connector Gen 3
-
serial_number
Data type Permission string R Serial number of the Tesla Wall Connector Gen 3
-
current_alerts
Data type Permission string R Read-Only string with details about alerts.
-
contactor_closed
Data type Permission boolean R Read-Only boolean indicating if the relais is closed.
-
grid_hz
Data type Permission number R Read-Only number representing the grids frequency.
-
config_status
Data type Permission number R Read-Only number representing the config status. Please help with details!
-
current[A,B,C,N]_a
Data type Permission number R Read-Only number representing the current of line [A,B,C,N] in ampere.
-
evse_state
Data type Permission number R *Read-Only number representing the evse state. We seem to know so far: 0=booting, 1=idle, 2=connect but not ready, 3=???, 4=connected and ready, 5=???, 6=vehicle plugged in and handshaking, 7=???, 8=charging completed/interrupted, 9=ready for charging but waiting on car, 10=charging with reduced power (less than 3 phases, 16 amps each), 11=charging full power (3 Phases, 16 amps each), 12=??? *
-
grid_v
Data type Permission number R Read-Only number representing the grids voltage.
-
handle_temp_c
Data type Permission number R Read-Only number representing the handle's tempearture in °C.
-
input_thermopile_uv
Data type Permission number R Read-Only number representing ???.
-
mcu_temp_c
Data type Permission number R Read-Only number representing the master control unit's tempearture in °C.
-
pcba_temp_c
Data type Permission number R Read-Only number representing the printed circuit board's tempearture in °C.
-
pilot_high_v
Data type Permission number R Read-Only number representing the pilot line's high voltage.
-
pilot_low_v
Data type Permission number R Read-Only number representing the pilot line's low voltage.
-
prox_v
Data type Permission number R Read-Only number representing ???.
-
relay_coil_v
Data type Permission number R Read-Only number representing the relay coils voltage.
-
session_s
Data type Permission number R Read-Only number representing the duration of the current charging session in seconds.
-
session_energy_wh
Data type Permission number R Read-Only number representing the energy supplied in the current session in Wh.
-
uptime_s
Data type Permission number R Read-Only number representing the WC3's uptime in seconds.
-
vehicle_connected
Data type Permission boolean R Read-Only boolean indicating if a vehicle is connected.
-
vehicle_current_a
Data type Permission number R Read-Only number representing vehicles current in ampere.
-
voltage[A,B,C]_v
Data type Permission number R Read-Only number representing the voltage of line [A,B,C].
-
internet
Data type Permission boolean R Read-only boolean, representing if the Tesla Wall Connector Gen 3 is connected to the internet.
-
wifi_connected
Data type Permission boolean R Read-only boolean, representing if the Tesla Wall Connector Gen 3 is connected to wifi.
-
wifi_infra_ip
Data type Permission string R Read-only string, representing the IP of the Tesla Wall Connector Gen 3.
-
wifi_mac
Data type Permission string R Read-only string, representing the MAC address of the Tesla Wall Connector Gen 3.
-
wifi_rssi
Data type Permission number R Read-only number, representing the rssi of the wifi the Tesla Wall Connector Gen 3 is connected to.
-
wifi_signal_strength
Data type Permission number R Read-only number, representing the signal strength of the wifi the Tesla Wall Connector Gen 3 is connected to.
-
wifi_snr
Data type Permission number R Read-only number, representing the snr of the wifi the Tesla Wall Connector Gen 3 is connected to.
-
wifi_ssid
Data type Permission string R SSID the Tesla Wall Connector Gen 3 is connected to.