Input variable listeners are never stopped #57

Closed
targos opened this issue Feb 11, 2014 · 2 comments
Closed

Input variable listeners are never stopped #57

targos opened this issue Feb 11, 2014 · 2 comments
Assignees
Labels

Comments

@targos
Copy link
Collaborator

targos commented Feb 11, 2014

Each time the configuration of a module is saved, a new listener is created, but the previous one is still here.
So in the situation where you edit 5 times de configuration, the "update" function will be called 5 times when an input variable changes

@targos
Copy link
Collaborator Author

targos commented Feb 14, 2014

Also this happens when another view is loaded

@targos
Copy link
Collaborator Author

targos commented May 16, 2014

And when the module is removed...