forked from npshub/mantid
-
Notifications
You must be signed in to change notification settings - Fork 0
/
TFXA_Parameters_Post-1993-10-06.xml
109 lines (82 loc) · 2.95 KB
/
TFXA_Parameters_Post-1993-10-06.xml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
<?xml version="1.0" encoding="UTF-8" ?>
<parameter-file instrument = "TXFA" valid-from="1993-10-06 18:50:00" valid-to="1998-05-26 12:04:46">
<component-link name = "TFXA">
<parameter name="deltaE-mode" type="string">
<value val="indirect"/>
</parameter>
<!-- These properties are neceessary for use in the Indirect CTE interface. -->
<parameter name="analysers" type="string">
<value val="graphite,diffraction" />
</parameter>
<parameter name="refl-graphite" type="string">
<value val="002" />
</parameter>
<parameter name="refl-diffraction" type="string">
<value val="diffspec" />
</parameter>
<!-- Available options are "true" or "false". -->
<parameter name="cm-1-convert-choice" type="string">
<value val="true" />
</parameter>
<parameter name="save-nexus-choice" type="string">
<value val="false" />
</parameter>
<parameter name="save-ascii-choice" type="string">
<value val="true" />
</parameter>
<parameter name="fold-frames-choice" type="string">
<value val="true" />
</parameter>
<!-- Reduction workflow parameters under this line -->
<parameter name="Workflow.InfoTable" type="string">
<value val="inst_abrv, run_number, user_name, run_title, hd_dur" />
</parameter>
<parameter name="rebin-default" type="string">
<value val="3,-0.005,500" />
</parameter>
<!-- This is actually spectrum index, NOT spectrum number -->
<parameter name="Workflow.Monitor1-SpectrumNumber" >
<value val="28" />
</parameter>
<parameter name="Workflow.Monitor1-Area" >
<value val="5.391011e-5" />
</parameter>
<parameter name="Workflow.Monitor1-Thickness" >
<value val="0.013" />
</parameter>
<parameter name="Workflow.Monitor1-ScalingFactor">
<value val="1e9" />
</parameter>
<parameter name="Workflow.Monitor1-Attenuation" >
<value val="8.3" />
</parameter>
<!-- This is actually spectrum index, NOT spectrum number -->
<parameter name="Workflow.Monitor2-SpectrumNumber" >
<value val="35" />
</parameter>
<parameter name="Workflow.Monitor2-Area" >
<value val="5.391011e-5" />
</parameter>
<parameter name="Workflow.Monitor2-Thickness" >
<value val="0.013" />
</parameter>
<parameter name="Workflow.Monitor2-ScalingFactor">
<value val="1e9" />
</parameter>
<parameter name="Workflow.Monitor2-Attenuation" >
<value val="8.3" />
</parameter>
<parameter name="Workflow.UnwrapMonitor" type="string">
<value val="Never" />
</parameter>
<parameter name="Workflow.ChopDataIfGreaterThan">
<value val="40000" />
</parameter>
<parameter name="Workflow.GroupingMethod" type="string">
<value val="All" />
</parameter>
<parameter name="Workflow.Masking" type="string">
<value val="IdentifyNoisyDetectors" />
</parameter>
</component-link>
</parameter-file>