forked from npshub/mantid
-
Notifications
You must be signed in to change notification settings - Fork 0
/
VISION_Parameters.xml
78 lines (69 loc) · 2.89 KB
/
VISION_Parameters.xml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
<?xml version="1.0" encoding="UTF-8" ?>
<parameter-file instrument = "VISION" valid-from = "2012-01-01T00:00:00">
<component-link name = "VISION">
<parameter name="deltaE-mode" type="string">
<value val="indirect"/>
</parameter>
<!-- These properties are neceessary for use in the Indirect CTE interface. -->
<parameter name="analysers" type="string">
<value val="graphite" />
</parameter>
<parameter name="refl-graphite" type="string">
<value val="002" />
</parameter>
<!-- Default Indirect Data Reduction > Energy Transfer GUI setup -->
<!-- Available options are "true" or "false" -->
<parameter name="cm-1-convert-choice" type="string">
<value val="false" />
</parameter>
<parameter name="save-ascii-choice" type="string">
<value val="false" />
</parameter>
<!-- This parameter will be taken as a default value for the rebinning of
the data in DeltaE. The existence of the parameter will make rebinning
the default, as opposed to not rebinning.
This is necessary so that the spectra can be grouped.
-->
<parameter name="rebin-default" type="string">
<value val="-2.5,0.015,3,-0.005,1000" />
</parameter>
<!-- Reduction workflow parameters under this line -->
<parameter name="Workflow.Monitor.RebinStep" >
<!-- This is the step size to optionally rebin the monitor to"-->
<value val="10.0" />
</parameter>
<parameter name="Workflow.Monitor1-SpectrumNumber" >
<value val="0" />
</parameter>
<parameter name="Workflow.Monitor1-Area" >
<value val="5.391011e-5" />
</parameter>
<parameter name="Workflow.Monitor1-Thickness" >
<value val="0.013" />
</parameter>
<parameter name="Workflow.Monitor1-ScalingFactor">
<value val="1e9" />
</parameter>
<parameter name="Workflow.UnwrapMonitor" type="string">
<value val="Never" />
</parameter>
<parameter name="Workflow.ChopDataIfGreaterThan">
<value val="40000" />
</parameter>
<parameter name="Workflow.GroupingMethod" type="string">
<value val="File" />
</parameter>
<parameter name="Workflow.GroupingFile" type="string">
<value val="VISION_Grouping.xml" />
</parameter>
<parameter name="Workflow.Masking" type="string">
<value val="IdentifyNoisyDetectors" />
</parameter>
<!-- Emission time from moderator, syntax below follows muParser, less-than sign escaped with the amperstand for correct xml parsing, incidentEnergy in meV, results in micro-seconds -->
<parameter name="t0_formula" type="string">
<value val="(incidentEnergy < 34.7332) ? 37.011296*incidentEnergy^(-0.052874) : (incidentEnergy < 88.7556) ? 124.267307*incidentEnergy^(-0.394282) : (incidentEnergy < 252.471) ? 963.775145*incidentEnergy^(-0.850919) : (incidentEnergy < 420.145) ? 33.225834*incidentEnergy^(-0.242105) : (incidentEnergy < 100000.0) ? 120.569231*incidentEnergy^(-0.455477) : 0.0" />
<!-- value val="370*incidentEnergy^(-0.1)" /-->
<!-- value val="40.0"/-->
</parameter>
</component-link>
</parameter-file>