Notifications
You must be signed in to change notification settings - Fork 11
/
registers.txt
186 lines (148 loc) · 3.86 KB
/
registers.txt
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
# overview of the registers of a jds6600 signal generator
# Kristoff Bonne (ON1ARF)
# version 20180126
# list
# for more info, see additional information below
# 00 to 01: hardware information registers
00 model
01 SN
# 20 to 31: "wave" mode
20 channel-enable (x,x)
21 wave1
22 wave2
23 frequency1
24 frequency2
25 amplitude1
26 amplitude2
27 offset1
28 offset2
29 dutycycle1
30 dutycycle2
31 phase
# 32 to 35: mode and UI registers
32 action (x,x,x,x)
33 mode (4 USB-bits, write 4 LSB-bits)
34 control UI menu
35 mode (simular to 33, read-only)
# 36 to 38: "measure" mode (control registers)
36 measure coupling
37 measure gate time
38 measure mode
# 39: reset counter
39 reset counter / burst reset counter / burst manual trigger: write 0 to register
# 40 to 44: "sweep" mode
40 sweep start freq
41 sweep end freq
42 sweep sweep time
43 sweep direction
44 sweep sweep-mode (lin/log)
# 45 to 48: "pulse" mode
45 pulse pulse-time
46 pulse T (periode)
47 pulse offset
48 pulse amplitude
# 49 to 50: "burst" mode
49 burst number of bursts
50 burst mode (trigger)
# 51 to 56: system settings
# see remarks about firmware-bug below
51 system READ: ----------- WRITE: sound
52 system READ: sound WRITE: brightness
53 system READ: brightness WRITE: language
54 system READ: language WRITE: syncronised
55 system READ: sync WRITE: ArbMaxNum
56 system READ: ArbMaxNum WRITE: -----------
# 70 to 72: profile actions (part of system menu)
70 profile save: write profile number to register
71 profile load: write profile number to register
72 profile clear: write profile number to register
# 80: "counter" mode (data)
80 counter counter
# 81 to 89: "measure" mode (data)
81 measure freq (Hz * 10)
82 measure freq (HZ * 1000)
83 measure PW+
84 measure PW-
85 measure T (periode)
86 measure dutycycle
87 measure unknown 1 (related to freq. related to gatetime), same as counter in "counter" mode
88 measure unknown 2 (inverse-related to freq.)
89 measure unknown 3 (inverse-related to freq.)
# 90 to 95: all zero
#### additional information
### "wave" mode:
** Register 20: channel-enable: 2-value field
(channel1 , channel 2)
** Register 21 and 22: waveform
0 = sine
1 = square
2 = pulse
3 = triangle
4 = partial Sine
5 = CMOS
6 = DC
7 = Half Wave
8 = Full Wave
9 = Pos. Lader
10 = Neg. Lader
11 = Noise
12 = Exp. Rise
13 = Exp. Decay
14 = Multi Tone
15 = Sinc
16 = Lorenz
101 to 160 = Arbitrary01 to Arbitrary60
** Register 23 and 24: frequency
Format: frequency,multiplier
Frequency: unit = Hz / 100
Multiplier:
0: 1 (Hz)
1: 1e3 (Khz)
2: 1e6 (MHz)
3: 1e-3 (mHz)
4: 1e-6 (µHz)
For multipliers 0 (Hz), 1 (KHz) and 2 (MHz), the multiplier setting only
changes the visualisation aspect of the frequency on the UI
For multipliers 2 (mHZ) and 3 (µ Hz), the multiplier affects both the
visualisation and the frequency!
Using multipliers 2 and 3 allows for setting the frequency with a precision
larger then 0.01 Hz.
The maximum frequencies are:
multipliers 0, 1 and 2: hardware limit of signal generator
multiplier 2: 80 KHz
multiplier 3: 80 Hz
** Register 25 and 26: amplitude
unit = mV
** Register 27 and 28: DC offset
unit = 0.01V, then add 1000
** Register 29 and 30: DutyCycle
unit = 0.1 degrees
#### Mode / action
Register 32: action
Count on: 1,0,0,0, Count off: 0,0,0,0
Sweep on: 0,1,0,0, Sweep off: 0,0,0,0
Pulse on: 1,0,1,1, Pulse off: 0,0,1,1
Burst on: 1,0,1,1, Burst off: 0,0,1,1
Register 33: mode
READING:
0: Wave menu, channel 1 on top
16: Wave menu, channel 2 on top
32: System menu
48: not used
64: Measure menu
72: Counter menu
80: Sweep/Channel1 menu
88: Sweep/Channel2 menu
96: Pulse menu
104: Burst menu
WRITING:
0: Wave menu, channel 1 on top
1: Wave menu, channel 2 on top
2: System menu
3: not used
4: Measure menu
5: Counter menu
6: Sweep/Channel1 menu
7: Sweep/Channel2 menu
8: Pulse menu
9: Burst menu