Notifications
You must be signed in to change notification settings - Fork 5
/
xdslimpulsenoisemonitorperformancemonitoringhistorydata.go
130 lines (120 loc) · 6.47 KB
/
xdslimpulsenoisemonitorperformancemonitoringhistorydata.go
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
/*
* Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net)
* Copyright 2020-present Open Networking Foundation
* Licensed under the Apache License, Version 2.0 (the "License");
* you may not use this file except in compliance with the License.
* You may obtain a copy of the License at
* http://www.apache.org/licenses/LICENSE-2.0
* Unless required by applicable law or agreed to in writing, software
* distributed under the License is distributed on an "AS IS" BASIS,
* WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
* See the License for the specific language governing permissions and
* limitations under the License.
*/
/*
* NOTE: This file was generated, manual edits will be overwritten!
*
* Generated by 'goCodeGenerator.py':
* https://github.com/cboling/OMCI-parser/README.md
*/
package generated
import "github.com/deckarep/golang-set"
// XdslImpulseNoiseMonitorPerformanceMonitoringHistoryDataClassID is the 16-bit ID for the OMCI
// Managed entity xDSL impulse noise monitor performance monitoring history data
const XdslImpulseNoiseMonitorPerformanceMonitoringHistoryDataClassID ClassID = ClassID(324)
var xdslimpulsenoisemonitorperformancemonitoringhistorydataBME *ManagedEntityDefinition
// XdslImpulseNoiseMonitorPerformanceMonitoringHistoryData (class ID #324)
// This ME collects PM data from the impulse noise monitor function at both near and far ends.
// Instances of this ME are created and deleted by the OLT. Note that, unlike most xDSL PM, [ITU-T
// G.997.1] only requires current and previous 15-min interval storage; a longer view of this PM is
// not expected at 15-min granularity.
//
// For a complete discussion of generic PM architecture, refer to clause I.4.
//
// Relationships
// An instance of this ME may be associated with an xDSL UNI. This ME is meaningful only for ITUT
// G.993.2 VDSL2, [ITUT G.992.3] and [ITUT-G.992.5].
//
// Attributes
// Managed Entity Id
// Managed entity ID: This attribute uniquely identifies each instance of this ME. The ME ID is
// identical to that of this ME's parent PPTP xDSL UNI part 1. (R, setbycreate) (mandatory)
// (2-bytes)
//
// Interval End Time
// Interval end time: This attribute identifies the most recently finished 15-min interval. (R)
// (mandatory) (1-byte)
//
// Threshold Data 1_2 Id
// Threshold data 1/2 ID: No thresholds are defined for this ME. For uniformity with other PM, the
// attribute is retained and shown as mandatory, but it should be set to a null pointer. (R,-W,
// setbycreate) (mandatory) (2-bytes)
//
// Inm Inpeq Histogram Table
// INM INPEQ histogram table: INMINPEQ1..17-L is a count of the near-end INMAINPEQi anomalies
// occurring on the line during the accumulation period. This parameter is subject to inhibiting -
// see clause 7.2.7.13 of [ITUT-G.997.1]. (R) (optional) (2-bytes * 17 entries-= 34-bytes)
//
// Inm Total Measurement
// INM total measurement: INMME-L is a count of the near-end INMAME anomalies occurring on the line
// during the accumulation period. This parameter is subject to inhibiting - see clause 7.2.7.13 of
// [ITUT G.997.1]. (R) (optional) (2-bytes)
//
// Inm Iat Histogram
// INM IAT histogram: INMIAT0..7-L is a count of the near-end INMAIATi anomalies occurring on the
// line during the accumulation period. This parameter is subject to inhibiting - see clause
// 7.2.7.13 of [ITUT G.997.1]. (R) (optional) (2-bytes-* 8 entries-= 16-bytes)
//
// Inm Inpeq Histogram Lfe Table
// INM INPEQ histogram LFE table: INMINPEQ1..17-LFE is a count of the far-end INMAINPEQi anomalies
// occurring on the line during the accumulation period. This parameter is subject to inhibiting -
// see clause 7.2.7.13 of [ITUT-G.997.1]. (R) (optional) (2-bytes * 17 entries-= 34-bytes)
//
// Inm Total Measurement Lfe
// INM total measurement LFE: INMME-LFE is a count of the far-end INMAME anomalies occurring on the
// line during the accumulation period. This parameter is subject to inhibiting - see clause
// 7.2.7.13 of [ITUT G.997.1]. (R) (optional) (2-bytes)
//
// Inm Iat Histogram Lfe
// INM IAT histogram LFE: INMIAT0..7-LFE is a count of the far-end INMAIATi anomalies occurring on
// the line during the accumulation period. This parameter is subject to inhibiting - see clause
// 7.2.7.13 of [ITUT G.997.1]. (R) (optional) (2-bytes-* 8 entries-= 16-bytes)
//
type XdslImpulseNoiseMonitorPerformanceMonitoringHistoryData struct {
ManagedEntityDefinition
Attributes AttributeValueMap
}
func init() {
xdslimpulsenoisemonitorperformancemonitoringhistorydataBME = &ManagedEntityDefinition{
Name: "XdslImpulseNoiseMonitorPerformanceMonitoringHistoryData",
ClassID: 324,
MessageTypes: mapset.NewSetWith(
Create,
Delete,
Get,
GetNext,
Set,
GetCurrentData,
),
AllowedAttributeMask: 0xff00,
AttributeDefinitions: AttributeDefinitionMap{
0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0),
1: ByteField("IntervalEndTime", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read), false, false, false, 1),
2: Uint16Field("ThresholdData12Id", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2),
3: TableField("InmInpeqHistogramTable", TableAttributeType, 0x2000, TableInfo{nil, 2}, mapset.NewSetWith(Read), false, true, false, 3),
4: Uint16Field("InmTotalMeasurement", CounterAttributeType, 0x1000, 0, mapset.NewSetWith(Read), false, true, false, 4),
5: Uint16Field("InmIatHistogram", CounterAttributeType, 0x0800, 0, mapset.NewSetWith(Read), false, true, false, 5),
6: TableField("InmInpeqHistogramLfeTable", TableAttributeType, 0x0400, TableInfo{nil, 2}, mapset.NewSetWith(Read), false, true, false, 6),
7: Uint16Field("InmTotalMeasurementLfe", CounterAttributeType, 0x0200, 0, mapset.NewSetWith(Read), false, true, false, 7),
8: Uint16Field("InmIatHistogramLfe", CounterAttributeType, 0x0100, 0, mapset.NewSetWith(Read), false, true, false, 8),
},
Access: CreatedByOlt,
Support: UnknownSupport,
}
}
// NewXdslImpulseNoiseMonitorPerformanceMonitoringHistoryData (class ID 324) creates the basic
// Managed Entity definition that is used to validate an ME of this type that
// is received from or transmitted to the OMCC.
func NewXdslImpulseNoiseMonitorPerformanceMonitoringHistoryData(params ...ParamData) (*ManagedEntity, OmciErrors) {
return NewManagedEntity(*xdslimpulsenoisemonitorperformancemonitoringhistorydataBME, params...)
}