This repository has been archived by the owner on May 17, 2021. It is now read-only.
/
msd2e.xml
252 lines (252 loc) · 15.3 KB
/
msd2e.xml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
<?xml version="1.0" encoding="utf-8"?>
<Product>
<Model>MSD2E</Model>
<Label lang="en">Micro Smart Dimmer 2nd Edition</Label>
<CommandClasses>
<Class><id>0x00</id></Class>
<Class><id>0x20</id></Class>
<Class><id>0x26</id></Class>
<Class><id>0x27</id></Class>
<Class><id>0x2B</id></Class>
<Class><id>0x2C</id></Class>
<Class><id>0x32</id></Class>
<Class><id>0x56</id></Class>
<Class><id>0x70</id></Class>
<Class><id>0x72</id></Class>
<Class><id>0x82</id></Class>
<Class><id>0x85</id></Class>
<Class><id>0x86</id></Class>
</CommandClasses>
<Associations>
<Group>
<Index>1</Index>
<Maximum>5</Maximum>
<Label lang="en">Target for automatic meter reports</Label>
<Label lang="de">Ziel für automatische Stromverbrauchsberichte</Label>
</Group>
<Group>
<Index>2</Index>
<Maximum>5</Maximum>
<Label lang="en">Target for automatic reports</Label>
<Label lang="de">Ziel für automatische reports</Label>
</Group>
</Associations>
<Configuration>
<Parameter>
<Index>2</Index>
<Type>short</Type>
<Minimum>0</Minimum>
<Maximum>65535</Maximum>
<Default>0</Default>
<Size>2</Size>
<WriteOnly>true</WriteOnly>
<Label lang="en">Make Micro Smart Dimmer 2nd Edition Blink</Label>
<Label lang="de">Make Micro Smart Dimmer 2nd Edition Blink</Label>
<Help lang="en">This is a double byte value. The LSB defines the total time the device need to blink. The value if set in seconds. The MSB defines the on/off interval of the blinking. The unit is 0.1 s.</Help>
<Help lang="de">This is a double byte value. The LSB defines the total time the device need to blink. The value if set in seconds. The MSB defines the on/off interval of the blinking. The unit is 0.1 s.</Help>
</Parameter>
<Parameter>
<Index>3</Index>
<Type>list</Type>
<Default>0</Default>
<Size>1</Size>
<Label lang="en">Current Overload Protection</Label>
<Label lang="de">Current Overload Protection</Label>
<Help lang="en">Load will be closed when current more that 2.7A and time more than 2 minutes</Help>
<Help lang="de">Load will be closed when current more that 2.7A and time more than 2 minutes</Help>
<Item>
<Value>0</Value>
<Label lang="en">Deactivate</Label>
<Label lang="de">Deaktiviert</Label>
</Item>
<Item>
<Value>1</Value>
<Label lang="en">Activate</Label>
<Label lang="de">Aktiviert</Label>
</Item>
</Parameter>
<Parameter>
<Index>13</Index>
<Type>list</Type>
<Default>0</Default>
<Size>1</Size>
<WriteOnly>true</WriteOnly>
<Label lang="en">Enable/Disable CRC16 encapsulation</Label>
<Label lang="de">Enable/Disable CRC16 encapsulation</Label>
<Help lang="en">Parameter to Enable/Disable CRC16 encapsulation</Help>
<Help lang="de">Parameter to Enable/Disable CRC16 encapsulation</Help>
<Item>
<Value>0</Value>
<Label lang="en">Deactivate</Label>
<Label lang="de">Deaktiviert</Label>
</Item>
<Item>
<Value>1</Value>
<Label lang="en">Activate</Label>
<Label lang="de">Aktiviert</Label>
</Item>
</Parameter>
<Parameter>
<Index>80</Index>
<Type>list</Type>
<Default>0</Default>
<Size>1</Size>
<Label lang="en">Notification on Status Change</Label>
<Label lang="de">Notification on Status Change</Label>
<Help lang="en">Parameter to Enable to send notification to associated devices (Group 1) when the state of Micro Smart Dimmer's load changed</Help>
<Help lang="de">Parameter to Enable to send notification to associated devices (Group 1) when the state of Micro Smart Dimmer's load changed</Help>
<Item>
<Value>0</Value>
<Label lang="en">Deactivate</Label>
<Label lang="de">Deaktiviert</Label>
</Item>
<Item>
<Value>1</Value>
<Label lang="en">Hail CC Sent</Label>
<Label lang="de">Hail CC Sent</Label>
</Item>
<Item>
<Value>2</Value>
<Label lang="en">Basic CC Report Sent</Label>
<Label lang="de">Basic CC Report Sent</Label>
</Item>
</Parameter>
<Parameter>
<Index>90</Index>
<Type>list</Type>
<Default>0</Default>
<Size>1</Size>
<Label lang="en">Automated sending of a Report triggered by minimal change of value.</Label>
<Label lang="de">Automated sending of a Report triggered by minimal change of value.</Label>
<Help lang="en">Parameter to Enable/Disable automated sending of a Report triggered by minimal change of value.</Help>
<Help lang="de">Parameter to Enable/Disable automated sending of a Report triggered by minimal change of value.</Help>
<Item>
<Value>0</Value>
<Label lang="en">Deavtivate</Label>
<Label lang="de">Deaktiviert</Label>
</Item>
<Item>
<Value>1</Value>
<Label lang="en">Activate</Label>
<Label lang="de">Aktiviert</Label>
</Item>
</Parameter>
<Parameter>
<Index>91</Index>
<Type>short</Type>
<Default>25</Default>
<Size>2</Size>
<Label lang="en">Minimum Change to send Report (Watt)</Label>
<Label lang="de">Minimum Change to send Report (Watt)</Label>
<Help lang="en">The value represents the minimum change in Wattage for a Report to be sent.</Help>
<Help lang="de">The value represents the minimum change in Wattage for a Report to be sent.</Help>
</Parameter>
<Parameter>
<Index>92</Index>
<Type>byte</Type>
<Default>5</Default>
<Size>1</Size>
<Label lang="en">Minimum Change to send Report (%)</Label>
<Label lang="de">Minimum Change to send Report (%)</Label>
<Help lang="en">The value represents the minimum change in Watage Percent for a report to be sent.</Help>
<Help lang="de">The value represents the minimum change in Watage Percent for a report to be sent.</Help>
</Parameter>
<Parameter>
<Index>101</Index>
<Type>int</Type>
<Default>4</Default>
<Size>4</Size>
<Label lang="en">Which reports need to send automatically in timing intervals for group 1</Label>
<Label lang="de">Welche Berichte sollen automatisch zu den definierten intervallen der Gruppe 1 gesendet werden</Label>
<Help lang="en">The value is a combination number made up of the sum of the values for the individual parameters.
The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1.
Therefore if you want all parameters sending regular reports, set the parameter to 15 (8 + 4 + 2 + 1).</Help>
<Help lang="de">The value is a combination number made up of the sum of the values for the individual parameters.
The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1.
Therefore if you want all parameters sending regular reports, set the parameter to 15 (8 + 4 + 2 + 1).</Help>
</Parameter>
<Parameter>
<Index>102</Index>
<Type>int</Type>
<Default>8</Default>
<Size>4</Size>
<Label lang="en">Which reports need to send automatically in timing intervals for group 2</Label>
<Label lang="de">Welche Berichte sollen automatisch zu den definierten intervallen der Gruppe 2 gesendet werden</Label>
<Help lang="en">The value is a combination number made up of the sum of the values for the individual parameters.
The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1.
Therefore if you want all parameters sending regular reports, set the parameter to 15 (8 + 4 + 2 + 1).</Help>
<Help lang="de">The value is a combination number made up of the sum of the values for the individual parameters.
The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1.
Therefore if you want all parameters sending regular reports, set the parameter to 15 (8 + 4 + 2 + 1).</Help>
</Parameter>
<Parameter>
<Index>103</Index>
<Type>int</Type>
<Default>0</Default>
<Size>4</Size>
<Label lang="en">Which reports need to send automatically in timing intervals for group 3</Label>
<Label lang="de">Welche Berichte sollen automatisch zu den definierten intervallen der Gruppe 3 gesendet werden</Label>
<Help lang="en">The value is a combination number made up of the sum of the values for the individual parameters.
The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1.
Therefore if you want all parameters sending regular reports, set the parameter to 15 (8 + 4 + 2 + 1).</Help>
<Help lang="de">The value is a combination number made up of the sum of the values for the individual parameters.
The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1.
Therefore if you want all parameters sending regular reports, set the parameter to 15 (8 + 4 + 2 + 1).</Help>
</Parameter>
<Parameter>
<Index>111</Index>
<Type>int</Type>
<Minimum>1</Minimum>
<Maximum>2678400</Maximum>
<Default>3</Default>
<Size>4</Size>
<Label lang="en">Interval to send out reports of group 1</Label>
<Label lang="de">Interval in welchem die Berichte der Gruppe 1 gesendet werden</Label>
</Parameter>
<Parameter>
<Index>112</Index>
<Type>int</Type>
<Minimum>1</Minimum>
<Maximum>2678400</Maximum>
<Default>600</Default>
<Size>4</Size>
<Label lang="en">Interval to send out reports of group 2</Label>
<Label lang="de">Interval in welchem die Berichte der Gruppe 2 gesendet werden</Label>
</Parameter>
<Parameter>
<Index>113</Index>
<Type>int</Type>
<Minimum>1</Minimum>
<Maximum>2678400</Maximum>
<Default>600</Default>
<Size>4</Size>
<Label lang="en">Interval to send out reports of group 3</Label>
<Label lang="de">Interval in welchem die Berichte der Gruppe 3 gesendet werden</Label>
</Parameter>
<Parameter>
<Index>120</Index>
<Type>list</Type>
<Default>255</Default>
<Size>1</Size>
<Label lang="en">Turn External Button Mode</Label>
<Label lang="de">Turn External Button Mode</Label>
<Help lang="en">Parameter to set External button type</Help>
<Help lang="de">Parameter to set External button type</Help>
<Item>
<Value>0</Value>
<Label lang="en">Momentary Button Mode</Label>
<Label lang="de">Momentary Button Mode</Label>
</Item>
<Item>
<Value>1</Value>
<Label lang="en">2 State Switch Mode</Label>
<Label lang="de">2 State Switch Mode</Label>
</Item>
<Item>
<Value>2</Value>
<Label lang="en">3 Way Switch Mode</Label>
<Label lang="de">3 Way Switch Mode</Label>
</Item>
</Parameter>
</Configuration>
</Product>