This repository has been archived by the owner on May 17, 2021. It is now read-only.
/
an181.xml
119 lines (116 loc) · 4.03 KB
/
an181.xml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
<?xml version="1.0" encoding="utf-8"?>
<Product>
<Model>AN181</Model>
<Label lang="en">Miniplug On/Off with meter function</Label>
<CommandClasses>
<Class><id>0x20</id></Class> <!-- COMMAND_CLASS_BASIC_V1 -->
<Class><id>0x22</id></Class> <!-- COMMAND_CLASS_APPLICATION_STATUS_V1 -->
<Class><id>0x25</id></Class> <!-- COMMAND_CLASS_SWITCH_BINARY_V1 -->
<Class><id>0x27</id></Class> <!-- COMMAND_CLASS_SWITCH_ALL_V1 -->
<Class><id>0x32</id></Class> <!-- COMMAND_CLASS_METER_V3 -->
<Class><id>0x59</id></Class> <!-- COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 -->
<Class><id>0x5a</id></Class> <!-- COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 -->
<Class><id>0x5e</id></Class> <!-- COMMAND_CLASS_ZWAVEPLUS_INFO_V2 -->
<Class><id>0x70</id></Class> <!-- COMMAND_CLASS_CONFIGURATION_V1 -->
<Class><id>0x71</id></Class> <!-- COMMAND_CLASS_NOTIFICATION_V4 -->
<Class><id>0x72</id></Class> <!-- COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 -->
<Class><id>0x73</id></Class> <!-- COMMAND_CLASS_POWERLEVEL_V1 -->
<Class><id>0x7a</id></Class> <!-- COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 -->
<Class><id>0x85</id></Class> <!-- COMMAND_CLASS_ASSOCIATION_V2-->
<Class><id>0x86</id></Class> <!-- COMMAND_CLASS_VERSION_V2 -->
</CommandClasses>
<Configuration>
<Parameter>
<Index>1</Index>
<Type>short</Type>
<Default>255</Default>
<Minimum>0</Minimum>
<Maximum>255</Maximum>
<Size>2</Size>
<Label lang="en">Basic Set Command</Label>
<Help lang="en"><![CDATA[Set Basic Set Command value to be sent to group 2 when switch is turned on.<br/>
When the physical button on the mini-plug is used to turn OFF the switch the value "0" will always be sent to group 2, however this is not the case when the switch is turned off remotely.]]></Help>
</Parameter>
<Parameter>
<Index>2</Index>
<Type>byte</Type>
<Default>3</Default>
<Minimum>3</Minimum>
<Maximum>25</Maximum>
<Size>1</Size>
<Label lang="en">Delay</Label>
<Help lang="en"><![CDATA[The delaying time to report to Group 1]]></Help>
</Parameter>
<Parameter>
<Index>3</Index>
<Type>list</Type>
<Default>1</Default>
<Minimum>0</Minimum>
<Maximum>1</Maximum>
<Size>1</Size>
<Label lang="en">Remember Last State</Label>
<Help lang="en"><![CDATA[Remember last status on plug]]></Help>
<Item>
<Value>0</Value>
<Label lang="en">Do not remember</Label>
</Item>
<Item>
<Value>1</Value>
<Label lang="en">Remember</Label>
</Item>
</Parameter>
<Parameter>
<Index>4</Index>
<Type>short</Type>
<Default>1</Default>
<Minimum>0</Minimum>
<Maximum>32767</Maximum>
<Size>2</Size>
<Label lang="en">Wattage Auto Report</Label>
<Help lang="en"><![CDATA[Set the interval for wattage auto report]]></Help>
</Parameter>
<Parameter>
<Index>5</Index>
<Type>short</Type>
<Default>60</Default>
<Minimum>0</Minimum>
<Maximum>32767</Maximum>
<Size>2</Size>
<Label lang="en">Energy Auto report</Label>
<Help lang="en"><![CDATA[Set the interval for kWh auto report (0 = disabled)]]></Help>
</Parameter>
<Parameter>
<Index>6</Index>
<Type>short</Type>
<Default>0</Default>
<Minimum>0</Minimum>
<Maximum>2500</Maximum>
<Size>2</Size>
<Label lang="en">Value of Wattage surpassed</Label>
<Help lang="en"><![CDATA[Auto report is sent when load surpasses the set value of wattage (0 = disabled)]]></Help>
</Parameter>
<Parameter>
<Index>7</Index>
<Type>short</Type>
<Default>0</Default>
<Minimum>0</Minimum>
<Maximum>100</Maximum>
<Size>2</Size>
<Label lang="en">Change of Wattage surpassed</Label>
<Help lang="en"><![CDATA[Auto report is sent when the change of wattage surpasses the set percentage (0 = disabled)]]></Help>
</Parameter>
</Configuration>
<Associations>
<Group>
<Index>1</Index>
<Maximum>1</Maximum>
<Label lang="en">Lifeline</Label>
<SetToController>true</SetToController>
</Group>
<Group>
<Index>2</Index>
<Maximum>4</Maximum>
<Label lang="en">On/Off control (Button on the mini-plug)</Label>
</Group>
</Associations>
</Product>