Skip to content

Latest commit

 

History

History
28 lines (25 loc) · 3.6 KB

File metadata and controls

28 lines (25 loc) · 3.6 KB

The device exposure domain captures information about a person's exposure to a foreign physical object or instrument that which is used for diagnostic or therapeutic purposes through a mechanism beyond chemical action. Devices include implantable objects (e.g. pacemakers, stents, artificial joints), medical equipment and supplies (e.g. bandages, crutches, syringes), other instruments used in medical procedures (e.g. sutures, defibrillators) and material used in clinical care (e.g. adhesives, body material, dental material, surgical material).

Field Required Type Description
device_exposure_id Yes integer A system-generated unique identifier for each Device Exposure.
person_id Yes integer A foreign key identifier to the Person who is subjected to the Device. The demographic details of that person are stored in the Person table.
device_concept_id Yes integer A foreign key that refers to a Standard Concept identifier in the Standardized Vocabularies for the Device concept.
device_exposure_start_date Yes date The date the Device or supply was applied or used.
device_exposure_start_datetime No datetime The date and time the Device or supply was applied or used.
device_exposure_end_date No date The date the Device or supply was removed from use.
device_exposure_end_datetime No datetime The date and time the Device or supply was removed from use.
device_type_concept_id Yes integer A foreign key to the predefined Concept identifier in the Standardized Vocabularies reflecting the type of Device Exposure recorded. It indicates how the Device Exposure was represented in the source data.
unique_device_id No varchar(50) A UDI or equivalent identifying the instance of the Device used in the Person.
quantity No integer The number of individual Devices used for the exposure.
provider_id No integer A foreign key to the provider in the PROVIDER table who initiated of administered the Device.
visit_occurrence_id No integer A foreign key to the visit in the VISIT table during which the device was used.
device_source_value No varchar(50) The source code for the Device as it appears in the source data. This code is mapped to a standard Device Concept in the Standardized Vocabularies and the original code is stored here for reference.
device_source_concept_id No integer A foreign key to a Device Concept that refers to the code used in the source.
visit_detail_id No integer A foreign key to the visit in the visit-detail table during which the Drug Exposure was initiated.

Conventions

  • The distinction between Devices or supplies and procedures are sometimes blurry, but the former are physical objects while the latter are actions, often to apply a Device or supply.
  • For medical devices that are regulated by the FDA, if a Unique Device Identification (UDI) is provided if available in the data source, and is recorded in the unique_device_id field.
  • Valid Device Concepts belong to the "Device" domain. The Concepts of this domain are derived from the DI portion of a UDI or based on other source vocabularies, like HCPCS.
  • A Device Type is assigned to each Device Exposure to track from what source the information was drawn or inferred. The valid domain_id for these Concepts is "Device Type".
  • The Visit during which the Device was first used is recorded through a reference to the VISIT_OCCURRENCE table. This information is not always available.
  • The Provider exposing the patient to the Device is recorded through a reference to the PROVIDER table. This information is not always available.