0x76 Visual Indicators

GM 0x00 → Broadcast 0xbf

This command is used to trigger the visual indicators for various Anti-Theft (DWA) and Cental Locking events.

The GM coding determines which indicators are triggered.

Related Commands

  • 0x72 Remote (Keyless) Entry
  • 0x74 Key Status

Example Frames

00 04 BF 76 00 CD
00 04 BF 76 02 CF
00 04 BF 76 82 4F

Parameters

Fixed length. One byte bitfield.

VISUAL_OFF          = 0b0000_0000

VISUAL_HAZARDS      = 0b0000_0001   # Hazard warning flashers
VISUAL_TURN_SIGNALS = 0b0000_0010   # Turn signals flashing
VISUAL_LOW_BEAMS    = 0b0000_0100   # Low beams flashing
VISUAL_HIGH_BEAMS   = 0b0000_1000   # High beams flashing

VISUAL_UNKNOWN      = 0b1000_0000

Visual Off 0b0000_0000

Visual indicators will remain active until they are deactivated.

Visual Hazards 0b0000_0001

This is akin to manually activating the hazard warning flashers via the central console.

Visual Turn Signals 0b0000_0010

Unlike the hazard warning flashers, there are no interior indicators, i.e. the cluster turn signal indicators are not activated.

Visual Low Beams 0b0000_0100

Low beams flashing at the same interval as the turn signals.

Visual High Beams 0b0000_1000

High beams flashing at the same interval as the turn signals.

Visual Unknown? 0b1000_0000

No apparent effect. I thought this may have been the acoustic indicator, but I believe that's via alarm siren which is controlled by GM, so I don't know!

Use Cases

Anti-Theft (DWA)

Any combination of the hazard warning lights, low beams, and high beams can be coded as visual indicators.

# General Module Coding: Anti-Theft (DWA) Indicators
# ZKE3 (GM3.C05)

ALARM_OPT_WARNBLINKER       # "Alarm Visual Warning Flashers"
ALARM_OPT_ABBLENDLICHT      # "Alarm Visual Low Beam"
ALARM_OPT_FERNLICHT         # "Alarm Visual High Beam"

Disabling the warning blinkers seems to be a bit tricky. TBC...

Central Locking

# General Module Coding: Central Locking Indicators
# ZKE3 (GM3.C05)
# Translations via NCS Dummy

QUIT_OPT_SCHAERF        # VISUAL LOCKING ACKNOWLEDGE (SINGLE TURN SIGNAL FLASH)
QUIT_OPT_ENTSCH         # VISUAL UNLOCKING ACKNOWLEDGE (TWO TURN SIGNAL FLASHES)

The same command is used to activate both a single, and double flash of the turn signals. The GM will simply allow one, or two cycles of the turn signals before deactivating.

# Central Locking
00 04 BF 76 02 CF   # Turn signals activated
00 04 BF 76 00 CD   # Turn signals deactivated

LM doesn't report turn signals via 0x5b... perhaps time based?