Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

configuration/homing.cfg G0 Z2 F1500 is in absolute not relative mode #25

Closed
sprior opened this issue Dec 6, 2021 · 1 comment
Closed

Comments

@sprior
Copy link

sprior commented Dec 6, 2021

Looking at configuration/homing.cfg:

Line 22 leaves the printer in absolute mode.
Line 38 the touches the nozzle to the z probe,
Line 39 then G0 Z2 F1500 which is intended to move the nozzle up, but if the z probe offset is more than 2mm it actually moves DOWN smashing into the Z probe.
I suggest adding a G91 just before line 39 as a fix.

@TitusLabs
Copy link
Member

Many thanks! I have changed it 👍