Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

The current MK3S extruder body is 0.4 mm loose(r) #119

Open
3Delights opened this issue Feb 15, 2019 · 3 comments
Open

The current MK3S extruder body is 0.4 mm loose(r) #119

3Delights opened this issue Feb 15, 2019 · 3 comments

Comments

@3Delights
Copy link

The user jonnieZG over on the Prusa Forum is reporting that: The current MK3S extruder body is 0.4 mm loose(r) and that it might be a good idea to change this as it is causing the extruder to wiggle.

Please see this forum topic:
https://shop.prusa3d.com/forum/general-discussion-announcements-and-releases-f69/the-current-mk3s-extruder-body-is-0-4-mm-loose-r--t27757.html#p128763

@jonnieZG
Copy link

jonnieZG commented Mar 6, 2019

User martin.a22 also pointed out here that it would be good to change the neck grip tolerances from +0.2 mm to 0.1 mm, so the neck socket diameters would be 16.1 mm and 12.1 mm. I added that to my mod here https://www.thingiverse.com/thing:3428292, but it might be a good idea to make the change on the official model as well.

@tstoegi
Copy link

tstoegi commented Jul 8, 2020

Still no comment or recommendation from Prusa yet?

@jonnieZG
Copy link

This issue is fixed in R6, as all tolerances are set to the values proposed here. R6 introduces also some other improvements, so we can close this issue as solved.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment