You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Version of Slic3r used goes here
Slic3r Prusa Edition
Use About->About Slic3r for release versions
1.40.1+
Operating system type + version
Apple MacOS 10.13.6
Behavior
Describe the problem
After saving a Bundle Configuration File attempts to reload it results in a "Duplicate section name" error.
This issue occurs before Adding an STL file or after. But I've included and STL file nonetheless.
Inspection of the ini file confirms a duplicate section. In the attached example bundle ini file it is near the end and is called: [printer:Original Prusa is MK3 0.6 nozzle]
Removal of the section results in same error when I attempt to load said file and re-inspection shows that it has been inserted back into the file: but why & where is this coming from?
Note that I've looked for duplicate individual Filament/Print/Printer Settings, but have not found any.
Considering that I have 1 bundle that I saved recently that works, this may not be a BUG in Slic3r and is probably a PEBKAC error - but what did I do?
Steps needed to reproduce the problem
Saving then using the Load Config Bundle function creates problem.
Expected Results
Load bundle and associated configuration files.
Actual Results
See error message above...
Screenshots from Slic3r preview are preferred
Is this a new feature request?
No
STL/Config (.gz) where problem occurs
Upload a zipped copy of an STL and your config (File -> Export Config)
Version
Version of Slic3r used goes here
Slic3r Prusa Edition
Use
About->About Slic3r
for release versions1.40.1+
Operating system type + version
Apple MacOS 10.13.6
Behavior
After saving a Bundle Configuration File attempts to reload it results in a "Duplicate section name" error.
This issue occurs before Adding an STL file or after. But I've included and STL file nonetheless.
Inspection of the ini file confirms a duplicate section. In the attached example bundle ini file it is near the end and is called: [printer:Original Prusa is MK3 0.6 nozzle]
Removal of the section results in same error when I attempt to load said file and re-inspection shows that it has been inserted back into the file: but why & where is this coming from?
Note that I've looked for duplicate individual Filament/Print/Printer Settings, but have not found any.
Considering that I have 1 bundle that I saved recently that works, this may not be a BUG in Slic3r and is probably a PEBKAC error - but what did I do?
Steps needed to reproduce the problem
Saving then using the Load Config Bundle function creates problem.
Expected Results
Load bundle and associated configuration files.
Actual Results
See error message above...
Screenshots from Slic3r preview are preferred
Is this a new feature request?
No
STL/Config (.gz) where problem occurs
Upload a zipped copy of an STL and your config (
File -> Export Config
)config.ini.gz
PETG PRUSA BLK 072018.ini.gz
ExampleSTL.stl.gz
The text was updated successfully, but these errors were encountered: