Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Documentation on ccu-mqtt #9

Closed
JMyrng opened this issue Nov 13, 2022 · 4 comments
Closed

Documentation on ccu-mqtt #9

JMyrng opened this issue Nov 13, 2022 · 4 comments

Comments

@JMyrng
Copy link

JMyrng commented Nov 13, 2022

Hi there,

thanks for maintaining this awesome software.

My hole smarthome is based on MQTT and I'd like to talk to the CCU3 with MQTT too.
Getting variables out works like a charm with the "ccu-mqtt" but I can't find a documentation on this input sceme. Where can I find the proper topics for setting some params in the CCU3?

Setup: NodeRed in Docker on Synology NAS, CCU3 for floor heating

Best regards,
Myrng

@ptweety
Copy link
Owner

ptweety commented Nov 13, 2022

My hole smarthome is based on MQTT and I'd like to talk to the CCU3 with MQTT too.

In this case I would strongly recommend the CCU-Jack as an add-on for your CCU

@JMyrng
Copy link
Author

JMyrng commented Nov 15, 2022

There are two things that bother me about this solution:

  1. I would like to run the CCU without additional software.
  2. CCU-Jack creates its own MQTT server, but I would like to use it with an existing server.

Where can I find information about this topic sceme:
hm/set/${channelNameOrAddress}/${datapoint}
Is it copied from CCU-Jack?

@ptweety
Copy link
Owner

ptweety commented Nov 15, 2022

  1. I would like to run the CCU without additional software.

Fair enough. As you can setup Node-RED within it's own docker container on your NAS the same applies to CCU-Jack.

  1. CCU-Jack creates its own MQTT server, but I would like to use it with an existing server.

As far as I know CCU-Jack can also act as a MQTT-Bridge.

Where can I find information about this topic sceme: hm/set/${channelNameOrAddress}/${datapoint} Is it copied from CCU-Jack?

No, it's not from CCU-Jack. I think it was made up by the original author of this node years ago ... See here

@JMyrng
Copy link
Author

JMyrng commented Nov 15, 2022

Thank you for your quick answers.

I've got it working on my side with the ccu-mqtt node.

In case anyone is ever looking for a similar solution:
To set the heating profile on a WTH-2 thermostat via ccu-mqtt node:

  1. ccu-mqtt node settings for setValue hm/set/${channelNameOrAddress}/${datapoint}
    where channelNameOrAddress is the serial number with the according channel, e.g. 000A9D8XXXXX41:1
    and datapoint is ACTIVE_PROFILE
    The name of the datapoint can be sourced in the outgoing mqtt messages of the device
  2. set up a mqtt-in node in front of the ccu-mqtt node with the topic hm/set/#
  3. just send the new profile number to the topic hm/set/000A9D8XXXXX41:1/ACTIVE_PROFILE

In my opinion, this is about as easy as it gets. Thank you again for this awesome module @ptweety!

@JMyrng JMyrng closed this as completed Nov 15, 2022
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment