Setup

Overview

The pypeit_file is the critical component to any successful run of PypeIt, and pypeit_setup provides an automated means of generating this file based on a set of fits files.

Below, we describe how PypeIt defines unique instrument configurations ("setups") and sorts data in preparation for the data reduction. Then we describe our recommended method for generating the pypeit_file, which includes multiple executions of pypeit_setup. We also describe another preparatory script, pypeit_obslog, which provides a simple listing of the available data files; however, use of this script is optional in terms of setup for reducing your data.

Use of Metadata to Identify Instrument Configurations

PypeIt distinguishes between instrument configurations using metadata pulled from the fits file headers, as defined specifically for each spectrograph. To list all of the metadata pulled from each data file and how it maps to the keywords in the data file headers, run, e.g.:

pypeit_obslog keck_deimos -k

(see pypeit_obslog and ~pypeit.spectrographs.spectrograph.Spectrograph.meta_key_map). For Keck/DEIMOS, this prints:

where the left column provides the PypeIt-specific metadata keyword and the right column is the associated instrument-specific header card. Any metadata element with a header card set to None means that the metadata keyword or value is conditioned on multiple header values. In this example, the header card that provides the central wavelength given the grating angle (dispangle) for DEIMOS is dependent on the grating used (dispname); see ~pypeit.spectrographs.keck_deimos.KeckDEIMOSSpectrograph.compound_meta.

A subset of this metadata is used to determine the unique instrument configurations used and associate all of the data files to the relevant configuration. Generally speaking, most instrument configurations are set by the name (dispname) and central wavelength (dispangle) of the dispersing element, the name of the decker or slit mask (decker), the name of the beam-splitting dichroic (dichroic), and/or the on-chip binning (binning). The specific set of metadata keys used for each instrument is set by the configuration_keys method; for DEIMOS, see ~pypeit.spectrographs.keck_deimos.KeckDEIMOSSpectrograph.configuration_keys.

The following table provides the list of metadata used to define the instrument configuration for any supported spectrograph (as of PypeIt version 1.10.1dev):

Metadata Key Type Example Description
amp str SINGLE:B Name of the amplifier used to read the detector
arm str VIS Name of the spectrograph arm used to collect the data
binning str 1,1 On-chip binning
cenwave str 7500.0 Central wavelength of the disperser
datasec str [1:256,1:512] The science region of the detector
decker str long_1.0 Name of the decker or slit mask
decker_secondary str long_1.0 Partial Slitmask/decker name; see mosfire_config_report
detector str CHIP1 Name of the detector
dichroic str 560 Name of the dichroic
dispangle float 7500.0 Central wavelength for the dispersing element at the observed angle
dispname str 830G Name of the dispersing element
filter1 str J Name of the order-sorting filter
slitlength str Slit length; see mosfire_config_report
slitwid str Slit width; see mosfire_config_report

Every unique combination of the relevant metadata found in any of the fits files to be reduced represents a unique instrument configuration for PypeIt to consider; these configurations can be determined automatically by pypeit_setup and will be identified by a capital letter, e.g., A. When executing run-pypeit, however, the instrument configuration is set by the setup_block in the pypeit_file and not redetermined by the fits files. The latter allows the user flexibility to override PypeIt's automated configuration settings. Currently, each pypeit_file should only provide data from one instrument configuration.

If you tend to observe with one instrument configuration and with a simple set of calibrations, then the setup to run PypeIt should be straightforward. However, if you use multiple configurations (e.g. gratings, grating tilts, slitmasks), then you must pay more careful attention to the setups.

Below, we describe how PypeIt automatically determines instrument configurations for a set of files and constructs auto-generated pypeit files.


pypeit_obslog

The pypeit_obslog script allows you to see a simple listing of the data files in a given directory (or directories) and the metadata that PypeIt will pull from their headers. As always, the script usage can be displayed by calling the script with the -h option:

For example, if you've been observing with Keck DEIMOS, you can go into the directory with the raw data and execute:

pypeit_obslog keck_deimos

Or you can point to the directory that you want to list:

pypeit_obslog keck_deimos -r /path/to/raw/data

The listing is printed to stdout, but you can also specify a file for the output. You can also select the metadata by which to sort the output, change the columns that are printed, etc.

By default, the columns provided in the output table are identical to the columns in the data_block of a pypeit_file; to print columns with all the metadata collected, add -c all to the command line.


pypeit_setup

pypeit_setup is the script one executes to prepare for the data reduction by automatically associating fits files to specific frame_types and collecting groups of frames taken using unique instrument configurations. The script usage can be displayed by calling the script with the -h option:

The following is a step-by-step procedure for preparing for the data reduction.

0. Prepare

Change your working directory to the one where you wish the reduced data products to appear. Any directory will do; however, you likely don't want this to be the same directory that holds the raw data.

1. First Execution

We recommend you first execute pypeit_setup like this:

pypeit_setup -r path_to_your_raw_data/LB -s keck_lris_blue

where the two command-line options are required and provide:

  • -s: Sets the spectrograph to be reduce. This is camera specific (e.g., you need to reduce LRIS red data separately from LRIS blue data).
  • -r: Sets the full path to the raw data and the root prefix of the FITS files

Specifically note that this first run does not include the -c argument.

This execution of pypeit_setup searches for all *.fits and *.fits.gz files with the provided root directory. Generally, the provided path should not contain a wild-card and it is best if you provide the full path; however, you can search through multiple directories as follows:

pypeit_setup -r "/Users/xavier/Keck/LRIS/data/2016apr06/Raw/*/LB" -s keck_lris_blue

2. Inspect the outputs

The call above creates two files in the setup_files/ folder, created where you executed pypeit_setup:

  • {spectrograph}.sorted: This shows the unique configurations and the list of frames associated with each configuration as determine by the automated procedures in PypeIt. Each unique configuration is given a capital letter identifier (e.g., A,B,C,D...).
  • {spectrograph}.obslog: This provides the default log file, identical to the result of running pypeit_obslog.

Here is an example .sorted file for some example Keck DEIMOS data:

This sorted file contains two configurations, A and B. The "setup block" (the information between the ###... and #--... lines) describes the instrument configuration specific to this setup as determined using the relevant metadata. Each "setup block" is followed by a table listing the files and relevant metadata for all files matched to that instrument configuration. The data provided is specific to each instrument, as defined by, e.g., ~pypeit.spectrographs.keck_deimos.KeckDEIMOSSpectrograph.pypeit_file_keys.

The sorted file is only provided as a means of assessing the automated setup identification and file sorting, and we encourage you to briefly review the results. You may recognize that you are missing calibrations or you may be surprised to see more configurations than you were expecting. In the latter case, you can help us improve the automated procedures in PypeIt by submitting an issue on GitHub (Submit an issue) and including the sorted file in the issue description.

Importantly, you should use the sorted file to decide which configuration (as selected by its letter) you wish to reduce. Also note that PypeIt cannot interpret any edits you make to this file; all user-level edits to the frame-typing, association of frames with given configurations, etc., must be done via the pypeit_file.

3. Second execution: Write the pypeit file for one or more setups

Provided you are happy with the sorted file, you should execute pypeit_setup a second time with the --cfg_split (shortcut -c) option. This will generate one or more sub-folders and populate each with a pypeit_file. Some example uses of the -c option are:

  • -c A: This will generate one folder+file for the chosen configuration
  • -c A,C: This will generate one folder+file for each input configuration
  • -c all: This will generate folders+files for all configurations

An example execution that only produces the pypeit_file for the A configuration is:

pypeit_setup -r path_to_your_raw_data/LB -s keck_lris_blue -c A

This example will generate a new folder named keck_lris_blue_A and within it will be a file named keck_lris_blue_A.pypeit.

4. Edit the pypeit file

You will likely need to edit your pypeit_file. This includes adding any desired changes to the parameter_block, adding/removing files from the data_block, correcting any erroneous frametypes (see frame_types), specifying any desired association between science and calibration frames (see calibration-groups), which science frames to combine (see 2d_combine), and which frames to use as backgrounds and/or part of an AB offset sequence (see a-b_differencing).

Warning

Any execution of run-pypeit will crash if your pypeit_file includes entries with None frame types defined. You must either remove or edit those entries in the pypeit file by-hand after running pypeit_setup.


Options

Consider your need for the following additional options:

-b option

You should consider using the -b option if you need to specify:

  • the calibration frames that should be used with each science frame (the same can be achieved by dividing your dataset into multiple .pypeit files that all use the same calibrations),
  • groups of science frames that should be combined, and/or
  • groups of frames that should be treated as background frames in an on-off (e.g., ABBA) observation sequence.

This simply adds the relevant columns to the pypeit_file that you must edit by hand: calib, comb_id, and bkg_id. These columns are added by default for most near-IR spectrographs. See calibrations and A-B_differencing for the syntax used for the data in these columns and how PypeIt uses them; see also a worked example in the gnirs_howto.

-m option

If you wish to include a column where you can include input for manual, use the -m option.