Calibration Coeffs Patmos-X 2017 #49

Closed
helgaweb opened this issue Jan 22, 2020 · 4 comments · Fixed by #50
Closed

Calibration Coeffs Patmos-X 2017 #49

helgaweb opened this issue Jan 22, 2020 · 4 comments · Fixed by #50

Comments

@helgaweb
Copy link

I found some twisted numbers for the metopb coeffs in the calibration.py script.
'metopb'
'bh' 1.478 -> 1.748
'bl' 1.478 -> 1.748
source:
https://cimss.ssec.wisc.edu/patmosx/instrument_files/avhrr_1_instr.dat
I further checked metopa, noaa18 and noaa19 - these are correct!

@ninahakansson
Copy link
Collaborator

Very good that you found it! Maybe that is causing all the problem with Metop-B calibration.

@mraspaud
Copy link
Member

@helgaweb do you feel like making a Pull Request for that ?

@sfinkens
Copy link
Member

I can assist of course

@helgaweb
Copy link
Author

Might be of interest for you. The plot shows the mean of the low and high calibration slopes for the day since launch until 2019 for MetOp-A CH3A.