Calibration Coeffs Patmos-X 2017 #49
Comments
Very good that you found it! Maybe that is causing all the problem with Metop-B calibration. |
@helgaweb do you feel like making a Pull Request for that ? |
I can assist of course |
Might be of interest for you. The plot shows the mean of the low and high calibration slopes for the day since launch until 2019 for MetOp-A CH3A. |
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
I found some twisted numbers for the metopb coeffs in the calibration.py script.
'metopb'
'bh' 1.478 -> 1.748
'bl' 1.478 -> 1.748
source:
https://cimss.ssec.wisc.edu/patmosx/instrument_files/avhrr_1_instr.dat
I further checked metopa, noaa18 and noaa19 - these are correct!
The text was updated successfully, but these errors were encountered: