within Modelica.Thermal.FluidHeatFlow.Examples;
model OneMass "Cooling of one hot mass"
extends Modelica.Icons.Example;
parameter FluidHeatFlow.Media.Medium medium=FluidHeatFlow.Media.Medium()
"Cooling medium" annotation (choicesAllMatching=true);
parameter SI.Temperature TAmb(displayUnit="degC")=293.15
"Ambient temperature";
parameter SI.Temperature TMass(displayUnit="degC")=313.15
"Initial temperature of mass";
output SI.TemperatureDifference dTMass=
heatCapacitor.port.T-TAmb "Temperature difference between mass and ambient condition";
output SI.TemperatureDifference dTtoPipe=heatCapacitor.port.T-pipe.T_q
"Temperature difference between mass and coolant";
output SI.TemperatureDifference dTCoolant=pipe.dT
"Coolant's temperature increase";
FluidHeatFlow.Sources.Ambient ambient1(
constantAmbientTemperature=TAmb,
medium=medium,
constantAmbientPressure=0)
annotation (Placement(transformation(extent={{-60,-10},{-80,10}})));
FluidHeatFlow.Sources.VolumeFlow pump(
medium=medium,
m=0,
T0=TAmb,
useVolumeFlowInput=true,
constantVolumeFlow=1)
annotation (Placement(transformation(extent={{-40,-10},{-20,10}})));
FluidHeatFlow.Components.Pipe pipe(
medium=medium,
m=0.1,
T0=TAmb,
V_flowLaminar=0.1,
dpLaminar(displayUnit="Pa") = 0.1,
V_flowNominal=1,
dpNominal(displayUnit="Pa") = 1,
h_g=0,
T0fixed=true,
useHeatPort=true)
annotation (Placement(transformation(extent={{0,-10},{20,10}})));
FluidHeatFlow.Sources.Ambient ambient2(
constantAmbientTemperature=TAmb,
medium=medium,
constantAmbientPressure=0)
annotation (Placement(transformation(extent={{40,-10},{60,10}})));
Modelica.Thermal.HeatTransfer.Components.HeatCapacitor heatCapacitor(
C=0.1, T(start=TMass, fixed=true))
annotation (Placement(transformation(
origin={10,-60},
extent={{10,-10},{-10,10}},
rotation=180)));
Modelica.Thermal.HeatTransfer.Components.ThermalConductor thermalConductor(G=1)
annotation (Placement(transformation(
origin={10,-30},
extent={{-10,-10},{10,10}},
rotation=90)));
FluidHeatFlow.Examples.Utilities.DoubleRamp volumeFlow(
offset=0,
height_1=1,
height_2=-2)
annotation (Placement(transformation(extent={{-60,10},{-40,30}})));
equation
connect(ambient1.flowPort, pump.flowPort_a)
annotation (Line(points={{-60,0},{-40,0}}, color={255,0,0}));
connect(pump.flowPort_b, pipe.flowPort_a)
annotation (Line(points={{-20,0},{0,0}}, color={255,0,0}));
connect(pipe.flowPort_b, ambient2.flowPort)
annotation (Line(points={{20,0},{40,0}}, color={255,0,0}));
connect(thermalConductor.port_a, heatCapacitor.port) annotation (Line(
points={{10,-40},{10,-45},{10,-50}}, color={191,0,0}));
connect(pipe.heatPort, thermalConductor.port_b)
annotation (Line(points={{10,-10},{10,-20}}, color={191,0,0}));
connect(volumeFlow.y, pump.volumeFlow) annotation (Line(
points={{-39,20},{-30,20},{-30,10}}, color={0,0,127}));
annotation (Documentation(info="<html>
<p>
7th test example: OneMass
</p>
A thermal capacity is coupled with a coolant flow.
Different initial temperatures of thermal capacity and pipe's coolant get ambient's temperature,
the time behaviour depending on coolant flow.
</html>"), experiment(StopTime=1.0, Interval=0.001));
end OneMass;