# Copyright (c) 2019-2022, RTE (https://www.rte-france.com)
# See AUTHORS.txt
# This Source Code Form is subject to the terms of the Mozilla Public License, version 2.0.
# If a copy of the Mozilla Public License, version 2.0 was not distributed with this file,
# you can obtain one at http://mozilla.org/MPL/2.0/.
# SPDX-License-Identifier: MPL-2.0
# This file is part of Grid2Op, Grid2Op a testbed platform to model sequential decision making in power systems.
import copy
import pdb
import time
import warnings
import unittest
import grid2op
from grid2op.Backend.educPandaPowerBackend import EducPandaPowerBackend
import pdb
class EducPPTester(unittest.TestCase):
"""mainly to test that a backend that do not support shunts_data can
be loaded properly.
"""
def test_make(self):
for env_name in grid2op.list_available_test_env():
if (env_name == "l2rpn_icaps_2021" or
env_name == "l2rpn_neurips_2020_track1" or
env_name == "l2rpn_wcci_2020" or
env_name == "l2rpn_wcci_2022_dev" or
env_name == "l2rpn_wcci_2022"
):
# does not work because of generators name
# in the redispatching data
# or name in the powerlines (when maintenance)
continue
with warnings.catch_warnings():
warnings.filterwarnings("ignore")
env = grid2op.make(env_name,
test=True,
backend=EducPandaPowerBackend(),
_add_to_name="educppbk")
assert type(env).n_shunt is None, f"error for {env_name}"
assert not type(env).shunts_data_available, f"error for {env_name}"
env.close()
if __name__ == "__main__":
unittest.main()