/
Parameters.py
465 lines (388 loc) · 22.8 KB
/
Parameters.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
# Copyright (c) 2019-2020, RTE (https://www.rte-france.com)
# See AUTHORS.txt
# This Source Code Form is subject to the terms of the Mozilla Public License, version 2.0.
# If a copy of the Mozilla Public License, version 2.0 was not distributed with this file,
# you can obtain one at http://mozilla.org/MPL/2.0/.
# SPDX-License-Identifier: MPL-2.0
# This file is part of Grid2Op, Grid2Op a testbed platform to model sequential decision making in power systems.
import os
import json
import warnings
from grid2op.dtypes import dt_int, dt_float, dt_bool
class Parameters:
"""
Main classes representing the parameters of the game. The main parameters are described bellow.
Note that changing the values of these parameters might not be enough. If these _parameters are not used in the
:class:`grid2op.Rules.RulesChecker`, then modifying them will have no impact at all.
Attributes
----------
NO_OVERFLOW_DISCONNECTION: ``bool``
If set to ``True`` then the :class:`grid2op.Environment.Environment` will not disconnect powerline above their
thermal
limit. Default is ``False``
NB_TIMESTEP_OVERFLOW_ALLOWED: ``int``
Number of timesteps for which a soft overflow is allowed, default 2. This means that a powerline will be
disconnected (if :attr:`.NO_OVERFLOW_DISCONNECTION` is set to ``False``) after 2 time steps above its thermal
limit. This is called a "soft overflow".
NB_TIMESTEP_RECONNECTION: ``int``
Number of timesteps a powerline disconnected for security motives (for example due to
:attr:`.NB_TIMESTEP_POWERFLOW_ALLOWED` or :attr:`.HARD_OVERFLOW_THRESHOLD`) will remain disconnected.
It's set to 10 timestep by default.
NB_TIMESTEP_COOLDOWN_LINE: ``int``
When someone acts on a powerline by changing its status (connected / disconnected) this number indicates
how many timesteps the :class:`grid2op.Agent.BaseAgent` has to wait before being able to modify this status
again.
For examle, if this is 1, this means that an BaseAgent can act on status of a powerline 1 out of 2 time step (1
time step it acts, another one it cools down, and the next one it can act again). Having it at 0 it equivalent
to deactivate this feature (default).
NB_TIMESTEP_COOLDOWN_SUB: ``int``
When someone changes the topology of a substations, this number indicates how many timesteps the
:class:`grid2op.Agent.BaseAgent` has to wait before being able to modify the topology on this same substation. It
has the same behaviour as :attr:`Parameters.NB_TIMESTEP_LINE_STATUS_REMODIF`. To deactivate this feature,
put it at 0 (default).
HARD_OVERFLOW_THRESHOLD: ``float``
If a the powerflow on a line is above HARD_OVERFLOW_THRESHOLD * thermal limit (and
:attr:`Parameters.NO_OVERFLOW_DISCONNECTION` is set to ``False``) then it is automatically disconnected,
regardless of
the number of timesteps it is on overflow). This is called a "hard overflow". This is expressed in relative
value of the thermal limits, for example, if for a powerline the `thermal_limit` is 150 and the
HARD_OVERFLOW_THRESHOLD is 2.0, then if the flow on the powerline reaches 2 * 150 = 300.0 the powerline
the powerline is automatically disconnected.
ENV_DC: ``bool``
Whether or not making the simulations of the environment in the "direct current" approximation. This can be
usefull for early training of agent, as this mode is much faster to compute than the corresponding
"alternative current" powerflow. It is also less precise. The default is ``False``
FORECAST_DC: ``bool``
DEPRECATED. Please use the "change_forecast_param" function of the environment
Whether to use the direct current approximation in the :func:`grid2op.Observation.BaseObservation.simulate`
method. Default is ``False``. Setting :attr:`FORECAST_DC` to `True` can speed up the computation of the
`simulate` function, but will make the results less accurate.
MAX_SUB_CHANGED: ``int``
Maximum number of substations that can be reconfigured between two consecutive timesteps by an
:class:`grid2op.Agent.BaseAgent`. Default value is 1.
MAX_LINE_STATUS_CHANGED: ``int``
Maximum number of powerlines statuses that can be changed between two consecutive timesteps by an
:class:`grid2op.Agent.BaseAgent`. Default value is 1.
IGNORE_MIN_UP_DOWN_TIME: ``bool``
Whether or not to ignore the attributes `gen_min_uptime` and `gen_min_downtime`. Basically setting this
parameter to ``True``
INIT_STORAGE_CAPACITY: ``float``
Between 0. and 1. Specify, at the beginning of each episode, what is the storage capacity of each storage unit.
The storage capacity will be expressed as fraction of storage_Emax. For example, if `INIT_STORAGE_CAPACITY` is
0.5 then at the beginning of every episode, all storage unit will have a storage capacity of
0.5 * `storage_Emax`. By default: `0.5`
ACTIVATE_STORAGE_LOSS: ``bool``
You can set it to ``False`` to not take into account the loss in the storage units.
This deactivates the "loss amount per time step" (`storage_loss`) and has also the effect to set
to do **as if** the
storage units were perfect (as if `storage_charging_efficiency=1.` and `storage_discharging_efficiency=1.`.
**NB** it does **as if** it were the case. But the parameters `storage_loss`, `storage_charging_efficiency`
and storage_discharging_efficiency` are not affected by this.
Default: ``True``
ALARM_BEST_TIME: ``int``
Number of step for which it's best to send an alarm BEFORE a game over
ALARM_WINDOW_SIZE: ``int``
Number of steps for which it's worth it to give an alarm (if an alarm is send outside of the window
`[ALARM_BEST_TIME - ALARM_WINDOW_SIZE, ALARM_BEST_TIME + ALARM_WINDOW_SIZE]` then it does not grant anything
"""
def __init__(self, parameters_path=None):
"""
Build an object representing the _parameters of the game.
Parameters
----------
parameters_path: ``str``, optional
Path where to look for parameters.
"""
# if True, then it will not disconnect lines above their thermal limits
self.NO_OVERFLOW_DISCONNECTION = False
# number of timestep before powerline with an overflow is automatically disconnected
self.NB_TIMESTEP_OVERFLOW_ALLOWED = dt_int(2)
# number of timestep before a line can be reconnected if it has suffer a forced disconnection
self.NB_TIMESTEP_RECONNECTION = dt_int(10)
# number of timestep before a substation topology can be modified again
self.NB_TIMESTEP_COOLDOWN_LINE = dt_int(0)
self.NB_TIMESTEP_COOLDOWN_SUB = dt_int(0)
# threshold above which a powerline is instantly disconnected by protections
# this is expressed in relative value of the thermal limits
# for example setting "HARD_OVERFLOW_THRESHOLD = 2" is equivalent, if a powerline has a thermal limit of
# 243 A, to disconnect it instantly if it has a powerflow higher than 2 * 243 = 486 A
self.HARD_OVERFLOW_THRESHOLD = dt_float(2.)
# are the powerflow performed by the environment in DC mode (dc powerflow) or AC (ac powerflow)
self.ENV_DC = False
# same as above, but for the forecast states
self.FORECAST_DC = False # DEPRECATED use "change_forecast_parameters(new_param)" with "new_param.ENV_DC=..."
# maximum number of substations that can be change in one action
self.MAX_SUB_CHANGED = dt_int(1)
# maximum number of powerline status that can be changed in one action
self.MAX_LINE_STATUS_CHANGED = dt_int(1)
# ignore the min_uptime and downtime for the generators: allow them to be connected / disconnected
# at will
self.IGNORE_MIN_UP_DOWN_TIME = True
# allow dispatch on turned off generator (if ``True`` you can actually dispatch a turned on geenrator)
self.ALLOW_DISPATCH_GEN_SWITCH_OFF = True
# storage capacity (NOT in pct)
self.INIT_STORAGE_CAPACITY = 0.5
# do i take into account the storage loss in the step function
self.ACTIVATE_STORAGE_LOSS = True
if parameters_path is not None:
if os.path.isfile(parameters_path):
self.init_from_json(parameters_path)
else:
warn_msg = "Parameters: the file {} is not found. Continuing with default parameters."
warnings.warn(warn_msg.format(parameters_path))
self.ALARM_BEST_TIME = 12
self.ALARM_WINDOW_SIZE = 12
@staticmethod
def _isok_txt(arg):
if isinstance(arg, type(True)):
return arg
if isinstance(arg, type("")):
arg = arg.strip("\"")
elif isinstance(arg, type(1)):
arg = "{}".format(arg)
res = False
if arg == "True" or arg == "T" or arg == "true" or arg == "t" or str(arg) == "1":
res = True
elif arg == "False" or arg == "F" or arg == "false" or arg == "f" or str(arg) == "0":
res = False
else:
msg = "It's ambiguous where an argument is True or False. " \
"Please only provide \"True\" or \"False\" and not {}"
raise RuntimeError(msg.format(arg))
return res
def init_from_dict(self, dict_):
"""
Initialize the object given a dictionary. All keys are optional. If a key is not present in the dictionary,
the default parameters is used.
Parameters
----------
dict_: ``dict``
The dictionary representing the parameters to load.
"""
if "NO_OVERFLOW_DISCONNECTION" in dict_:
self.NO_OVERFLOW_DISCONNECTION = Parameters._isok_txt(dict_["NO_OVERFLOW_DISCONNECTION"])
if "IGNORE_MIN_UP_DOWN_TIME" in dict_:
self.IGNORE_MIN_UP_DOWN_TIME = Parameters._isok_txt(dict_["IGNORE_MIN_UP_DOWN_TIME"])
if "ALLOW_DISPATCH_GEN_SWITCH_OFF" in dict_:
self.ALLOW_DISPATCH_GEN_SWITCH_OFF = Parameters._isok_txt(dict_["ALLOW_DISPATCH_GEN_SWITCH_OFF"])
if "NB_TIMESTEP_POWERFLOW_ALLOWED" in dict_:
self.NB_TIMESTEP_OVERFLOW_ALLOWED = dt_int(dict_["NB_TIMESTEP_POWERFLOW_ALLOWED"])
if "NB_TIMESTEP_OVERFLOW_ALLOWED" in dict_:
self.NB_TIMESTEP_OVERFLOW_ALLOWED = dt_int(dict_["NB_TIMESTEP_OVERFLOW_ALLOWED"])
if "NB_TIMESTEP_RECONNECTION" in dict_:
self.NB_TIMESTEP_RECONNECTION = dt_int(dict_["NB_TIMESTEP_RECONNECTION"])
if "HARD_OVERFLOW_THRESHOLD" in dict_:
self.HARD_OVERFLOW_THRESHOLD = dt_float(dict_["HARD_OVERFLOW_THRESHOLD"])
if "ENV_DC" in dict_:
self.ENV_DC = Parameters._isok_txt(dict_["ENV_DC"])
if "FORECAST_DC" in dict_:
new_val = Parameters._isok_txt(dict_["FORECAST_DC"])
if new_val != self.FORECAST_DC:
warnings.warn("The FORECAST_DC attributes is deprecated. Please change the parameters of the "
"\"forecast\" backend with \"env.change_forecast_parameters(new_param)\" function "
"with \"new_param.ENV_DC=...\" ")
self.FORECAST_DC = new_val
if "MAX_SUB_CHANGED" in dict_:
self.MAX_SUB_CHANGED = dt_int(dict_["MAX_SUB_CHANGED"])
if "MAX_LINE_STATUS_CHANGED" in dict_:
self.MAX_LINE_STATUS_CHANGED = dt_int(dict_["MAX_LINE_STATUS_CHANGED"])
if "NB_TIMESTEP_TOPOLOGY_REMODIF" in dict_:
# for backward compatibility (in case of old dataset)
self.NB_TIMESTEP_COOLDOWN_SUB = dt_int(dict_["NB_TIMESTEP_TOPOLOGY_REMODIF"])
if "NB_TIMESTEP_COOLDOWN_SUB" in dict_:
self.NB_TIMESTEP_COOLDOWN_SUB = dt_int(dict_["NB_TIMESTEP_COOLDOWN_SUB"])
if "NB_TIMESTEP_LINE_STATUS_REMODIF" in dict_:
# for backward compatibility (in case of old dataset)
self.NB_TIMESTEP_COOLDOWN_LINE = dt_int(dict_["NB_TIMESTEP_LINE_STATUS_REMODIF"])
if "NB_TIMESTEP_COOLDOWN_LINE" in dict_:
self.NB_TIMESTEP_COOLDOWN_LINE = dt_int(dict_["NB_TIMESTEP_COOLDOWN_LINE"])
# storage parameters
if "INIT_STORAGE_CAPACITY" in dict_:
self.INIT_STORAGE_CAPACITY = dt_float(dict_["INIT_STORAGE_CAPACITY"])
if "ACTIVATE_STORAGE_LOSS" in dict_:
self.ACTIVATE_STORAGE_LOSS = Parameters._isok_txt(dict_["ACTIVATE_STORAGE_LOSS"])
# alarm parameters
if "ALARM_BEST_TIME" in dict_:
self.ALARM_BEST_TIME = dt_int(dict_["ALARM_BEST_TIME"])
if "ALARM_WINDOW_SIZE" in dict_:
self.ALARM_WINDOW_SIZE = dt_int(dict_["ALARM_WINDOW_SIZE"])
authorized_keys = set(self.__dict__.keys())
authorized_keys = authorized_keys | {'NB_TIMESTEP_POWERFLOW_ALLOWED',
'NB_TIMESTEP_TOPOLOGY_REMODIF',
"NB_TIMESTEP_LINE_STATUS_REMODIF"}
ignored_keys = dict_.keys() - authorized_keys
if len(ignored_keys):
warnings.warn("Parameters: The _parameters \"{}\" used to build the Grid2Op.Parameters "
"class are not recognized and will be ignored.".format(ignored_keys))
def to_dict(self):
"""
Serialize all the _parameters as a dictionnary; Useful to write it in json format.
Returns
-------
res: ``dict``
A representation of these _parameters in the form of a dictionnary.
"""
res = {}
res["NO_OVERFLOW_DISCONNECTION"] = bool(self.NO_OVERFLOW_DISCONNECTION)
res["IGNORE_MIN_UP_DOWN_TIME"] = bool(self.IGNORE_MIN_UP_DOWN_TIME)
res["ALLOW_DISPATCH_GEN_SWITCH_OFF"] = bool(self.ALLOW_DISPATCH_GEN_SWITCH_OFF)
res["NB_TIMESTEP_OVERFLOW_ALLOWED"] = int(self.NB_TIMESTEP_OVERFLOW_ALLOWED)
res["NB_TIMESTEP_RECONNECTION"] = int(self.NB_TIMESTEP_RECONNECTION)
res["HARD_OVERFLOW_THRESHOLD"] = float(self.HARD_OVERFLOW_THRESHOLD)
res["ENV_DC"] = bool(self.ENV_DC)
res["FORECAST_DC"] = bool(self.FORECAST_DC)
res["MAX_SUB_CHANGED"] = int(self.MAX_SUB_CHANGED)
res["MAX_LINE_STATUS_CHANGED"] = int(self.MAX_LINE_STATUS_CHANGED)
res["NB_TIMESTEP_COOLDOWN_LINE"] = int(self.NB_TIMESTEP_COOLDOWN_LINE)
res["NB_TIMESTEP_COOLDOWN_SUB"] = int(self.NB_TIMESTEP_COOLDOWN_SUB)
res["INIT_STORAGE_CAPACITY"] = float(self.INIT_STORAGE_CAPACITY)
res["ACTIVATE_STORAGE_LOSS"] = bool(self.ACTIVATE_STORAGE_LOSS)
res["ALARM_BEST_TIME"] = int(self.ALARM_BEST_TIME)
res["ALARM_WINDOW_SIZE"] = int(self.ALARM_WINDOW_SIZE)
return res
def init_from_json(self, json_path):
"""
Set member attributes from a json file
Parameters
----------
json_path: ``str``
The complete (*ie.* path + filename) where the json file is located.
"""
try:
with open(json_path) as f:
dict_ = json.load(f)
self.init_from_dict(dict_)
except Exception as exc_:
warn_msg = "Could not load from {}\n" \
"Continuing with default parameters. \n\nThe error was \"{}\""
warnings.warn(warn_msg.format(json_path, exc_))
def __eq__(self, other):
this_dict = self.to_dict()
other_dict = other.to_dict()
return this_dict == other_dict
@staticmethod
def from_json(json_path):
"""
Create instance of a Parameters from a path where is a json is saved.
Parameters
----------
json_path: ``str``
The complete (*ie.* path + filename) where the json file is located.
Returns
-------
res: :class:`Parameters`
The _parameters initialized
"""
res = Parameters(json_path)
return res
def check_valid(self):
"""
check the parameter is valid (ie it checks that all the values are of correct types and within the
correct range.
Raises
-------
An exception if the parameter is not valid
"""
try:
if not isinstance(self.NO_OVERFLOW_DISCONNECTION, (bool, dt_bool)):
raise RuntimeError("NO_OVERFLOW_DISCONNECTION should be a boolean")
self.NO_OVERFLOW_DISCONNECTION = dt_bool(self.NO_OVERFLOW_DISCONNECTION)
except Exception as exc_:
raise RuntimeError(f"Impossible to convert NO_OVERFLOW_DISCONNECTION to bool with error \n:\"{exc_}\"")
try:
self.NB_TIMESTEP_OVERFLOW_ALLOWED = int(self.NB_TIMESTEP_OVERFLOW_ALLOWED) # to raise if numpy array
self.NB_TIMESTEP_OVERFLOW_ALLOWED = dt_int(self.NB_TIMESTEP_OVERFLOW_ALLOWED)
except Exception as exc_:
raise RuntimeError(f"Impossible to convert NB_TIMESTEP_OVERFLOW_ALLOWED to int with error \n:\"{exc_}\"")
if self.NB_TIMESTEP_OVERFLOW_ALLOWED < 0:
raise RuntimeError("NB_TIMESTEP_OVERFLOW_ALLOWED < 0., this should be >= 0.")
try:
self.NB_TIMESTEP_RECONNECTION = int(self.NB_TIMESTEP_RECONNECTION) # to raise if numpy array
self.NB_TIMESTEP_RECONNECTION = dt_int(self.NB_TIMESTEP_RECONNECTION)
except Exception as exc_:
raise RuntimeError(f"Impossible to convert NB_TIMESTEP_RECONNECTION to int with error \n:\"{exc_}\"")
if self.NB_TIMESTEP_RECONNECTION < 0:
raise RuntimeError("NB_TIMESTEP_RECONNECTION < 0., this should be >= 0.")
try:
self.NB_TIMESTEP_COOLDOWN_LINE = int(self.NB_TIMESTEP_COOLDOWN_LINE)
self.NB_TIMESTEP_COOLDOWN_LINE = dt_int(self.NB_TIMESTEP_COOLDOWN_LINE)
except Exception as exc_:
raise RuntimeError(f"Impossible to convert NB_TIMESTEP_COOLDOWN_LINE to int with error \n:\"{exc_}\"")
if self.NB_TIMESTEP_COOLDOWN_LINE < 0:
raise RuntimeError("NB_TIMESTEP_COOLDOWN_LINE < 0., this should be >= 0.")
try:
self.NB_TIMESTEP_COOLDOWN_SUB = int(self.NB_TIMESTEP_COOLDOWN_SUB) # to raise if numpy array
self.NB_TIMESTEP_COOLDOWN_SUB = dt_int(self.NB_TIMESTEP_COOLDOWN_SUB)
except Exception as exc_:
raise RuntimeError(f"Impossible to convert NB_TIMESTEP_COOLDOWN_SUB to int with error \n:\"{exc_}\"")
if self.NB_TIMESTEP_COOLDOWN_SUB < 0:
raise RuntimeError("NB_TIMESTEP_COOLDOWN_SUB < 0., this should be >= 0.")
try:
self.HARD_OVERFLOW_THRESHOLD = float(self.HARD_OVERFLOW_THRESHOLD) # to raise if numpy array
self.HARD_OVERFLOW_THRESHOLD = dt_float(self.HARD_OVERFLOW_THRESHOLD)
except Exception as exc_:
raise RuntimeError(f"Impossible to convert HARD_OVERFLOW_THRESHOLD to float with error \n:\"{exc_}\"")
if self.HARD_OVERFLOW_THRESHOLD < 1.:
raise RuntimeError("HARD_OVERFLOW_THRESHOLD < 1., this should be >= 1. (use env.set_thermal_limit "
"to modify the thermal limit)")
try:
if not isinstance(self.ENV_DC, (bool, dt_bool)):
raise RuntimeError("NO_OVERFLOW_DISCONNECTION should be a boolean")
self.ENV_DC = dt_bool(self.ENV_DC)
except Exception as exc_:
raise RuntimeError(f"Impossible to convert ENV_DC to bool with error \n:\"{exc_}\"")
try:
self.MAX_SUB_CHANGED = int(self.MAX_SUB_CHANGED) # to raise if numpy array
self.MAX_SUB_CHANGED = dt_int(self.MAX_SUB_CHANGED)
except Exception as exc_:
raise RuntimeError(f"Impossible to convert MAX_SUB_CHANGED to int with error \n:\"{exc_}\"")
if self.MAX_SUB_CHANGED < 0:
raise RuntimeError("MAX_SUB_CHANGED should be >=0 (or -1 if you want to be able to change every "
"substation at once)")
try:
self.MAX_LINE_STATUS_CHANGED = int(self.MAX_LINE_STATUS_CHANGED) # to raise if numpy array
self.MAX_LINE_STATUS_CHANGED = dt_int(self.MAX_LINE_STATUS_CHANGED)
except Exception as exc_:
raise RuntimeError(f"Impossible to convert MAX_LINE_STATUS_CHANGED to int with error \n:\"{exc_}\"")
if self.MAX_LINE_STATUS_CHANGED < 0:
raise RuntimeError("MAX_LINE_STATUS_CHANGED should be >=0 "
"(or -1 if you want to be able to change every powerline at once)")
try:
if not isinstance(self.IGNORE_MIN_UP_DOWN_TIME, (bool, dt_bool)):
raise RuntimeError("IGNORE_MIN_UP_DOWN_TIME should be a boolean")
self.IGNORE_MIN_UP_DOWN_TIME = dt_bool(self.IGNORE_MIN_UP_DOWN_TIME)
except Exception as exc_:
raise RuntimeError(f"Impossible to convert IGNORE_MIN_UP_DOWN_TIME to bool with error \n:\"{exc_}\"")
try:
if not isinstance(self.ALLOW_DISPATCH_GEN_SWITCH_OFF, (bool, dt_bool)):
raise RuntimeError("ALLOW_DISPATCH_GEN_SWITCH_OFF should be a boolean")
self.ALLOW_DISPATCH_GEN_SWITCH_OFF = dt_bool(self.ALLOW_DISPATCH_GEN_SWITCH_OFF)
except Exception as exc_:
raise RuntimeError(f"Impossible to convert ALLOW_DISPATCH_GEN_SWITCH_OFF to bool with error \n:\"{exc_}\"")
try:
self.INIT_STORAGE_CAPACITY = float(self.INIT_STORAGE_CAPACITY) # to raise if numpy array
self.INIT_STORAGE_CAPACITY = dt_float(self.INIT_STORAGE_CAPACITY)
except Exception as exc_:
raise RuntimeError(f"Impossible to convert INIT_STORAGE_CAPACITY to float with error \n:\"{exc_}\"")
if self.INIT_STORAGE_CAPACITY < 0.:
raise RuntimeError("INIT_STORAGE_CAPACITY < 0., this should be within range [0., 1.]")
if self.INIT_STORAGE_CAPACITY > 1.:
raise RuntimeError("INIT_STORAGE_CAPACITY > 1., this should be within range [0., 1.]")
try:
if not isinstance(self.ACTIVATE_STORAGE_LOSS, (bool, dt_bool)):
raise RuntimeError("ACTIVATE_STORAGE_LOSS should be a boolean")
self.ACTIVATE_STORAGE_LOSS = dt_bool(self.ACTIVATE_STORAGE_LOSS)
except Exception as exc_:
raise RuntimeError(f"Impossible to convert ACTIVATE_STORAGE_LOSS to bool with error \n:\"{exc_}\"")
try:
self.ALARM_WINDOW_SIZE = dt_int(self.ALARM_WINDOW_SIZE)
except Exception as exc_:
raise RuntimeError(f"Impossible to convert ALARM_WINDOW_SIZE to int with error \n:\"{exc_}\"")
try:
self.ALARM_BEST_TIME = dt_int(self.ALARM_BEST_TIME)
except Exception as exc_:
raise RuntimeError(f"Impossible to convert ALARM_BEST_TIME to int with error \n:\"{exc_}\"")
if self.ALARM_WINDOW_SIZE <= 0:
raise RuntimeError("self.ALARM_WINDOW_SIZE should be a positive integer !")
if self.ALARM_BEST_TIME <= 0:
raise RuntimeError("self.ALARM_BEST_TIME should be a positive integer !")