what feedback can we read how #52

Open
rusefillc opened this issue Aug 1, 2022 · 1 comment
Open

what feedback can we read how #52

rusefillc opened this issue Aug 1, 2022 · 1 comment
Assignees

Comments

@rusefillc
Copy link
Contributor

https://www.st.com/resource/en/datasheet/vnd14nv04.pdf

image

image

image

Q1: do we get only "1 bit of fault feedback" effectively "shorted to power" and nothing else? no way to detect missing load/injector/solenoid?

Q2: would stm32 be able to read feedback on current alphax-4chan schematics?

@Qwerty-OFF
Copy link
Collaborator

Q1: only "1 bit of fault feedback" effectively "shorted to power" and nothing else
Q2: No, an additional feedback line to MM module is required.