GM fuel pressure decoding #146
Comments
progress under #148 10 bar looks great
no pressure - probably should it be close to 1 @dron0gus ? what does it show on your end?
|
No pressure. Saint-P. Almost sea level.
|
How high does this sensor go? If it's a GDI sensor, I'd expect at least 200 bar, so 0.05 bar resolution isn't terrible. 200/0.05 is 12 bits. |
Actual resolution seems 1/10 Atm rusefi-hardware/SENT-box/firmware/sent.cpp Line 458 in fc7550c
But we can get 0.05 by averaging two signals. |
Hi, |
@floods57 all the code is at https://github.com/rusefi/rusefi-hardware/tree/main/SENT-box/firmware |
@floods57 can you share partnumber(s) of these sensors? |
Thanks a lot ;) |
@floods57 thanks for partnumbers. |
Ok, but i am not sure about the code i must use, i looking for the same as in this video : https://www.youtube.com/watch?v=S2xH2oOEYL8 i looking to do a similar testing with a Blue Pill to 1st find the value of the sensor. |
@floods57 for bluepill use https://github.com/rusefi/rusefi-hardware/tree/main/SENT-box/firmware code. But check main RusEFI FW for possible updates, changes. |
04E906051H
|
Pinout: |
Ok, Thanks i will try it ;) |
Ok, so many chance that the 04E906051J use the same pinout, will try it, look really difficult to get any information for this sensor. |
@dron0gus By the way, did you use a RC filter ? Thanks |
@floods57 do you mean input RC filter? No, I'm debuging on MRE board and using analog input with filter C removed. So signal path is OpAmp with K = 1 -> 1/2 divider -> STM32 pin. |
ambient room
10 bar = 1000 KPa