Notifications
You must be signed in to change notification settings - Fork 110
/
runpf.py
315 lines (257 loc) · 12.7 KB
/
runpf.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
# Copyright (c) 1996-2015 PSERC. All rights reserved.
# Use of this source code is governed by a BSD-style
# license that can be found in the LICENSE file.
"""Runs a power flow.
"""
from sys import stdout, stderr
from os.path import dirname, join
from time import time
from numpy import r_, c_, ix_, zeros, pi, ones, exp, argmax
from numpy import flatnonzero as find
from pypower.bustypes import bustypes
from pypower.ext2int import ext2int
from pypower.loadcase import loadcase
from pypower.ppoption import ppoption
from pypower.ppver import ppver
from pypower.makeBdc import makeBdc
from pypower.makeSbus import makeSbus
from pypower.dcpf import dcpf
from pypower.makeYbus import makeYbus
from pypower.newtonpf import newtonpf
from pypower.fdpf import fdpf
from pypower.gausspf import gausspf
from pypower.makeB import makeB
from pypower.pfsoln import pfsoln
from pypower.printpf import printpf
from pypower.savecase import savecase
from pypower.int2ext import int2ext
from pypower.idx_bus import PD, QD, VM, VA, GS, BUS_TYPE, PQ, REF
from pypower.idx_brch import PF, PT, QF, QT
from pypower.idx_gen import PG, QG, VG, QMAX, QMIN, GEN_BUS, GEN_STATUS
def runpf(casedata=None, ppopt=None, fname='', solvedcase=''):
"""Runs a power flow.
Runs a power flow [full AC Newton's method by default] and optionally
returns the solved values in the data matrices, a flag which is C{True} if
the algorithm was successful in finding a solution, and the elapsed
time in seconds. All input arguments are optional. If C{casename} is
provided it specifies the name of the input data file or dict
containing the power flow data. The default value is 'case9'.
If the ppopt is provided it overrides the default PYPOWER options
vector and can be used to specify the solution algorithm and output
options among other things. If the 3rd argument is given the pretty
printed output will be appended to the file whose name is given in
C{fname}. If C{solvedcase} is specified the solved case will be written
to a case file in PYPOWER format with the specified name. If C{solvedcase}
ends with '.mat' it saves the case as a MAT-file otherwise it saves it
as a Python-file.
If the C{ENFORCE_Q_LIMS} options is set to C{True} [default is false] then
if any generator reactive power limit is violated after running the AC
power flow, the corresponding bus is converted to a PQ bus, with Qg at
the limit, and the case is re-run. The voltage magnitude at the bus
will deviate from the specified value in order to satisfy the reactive
power limit. If the reference bus is converted to PQ, the first
remaining PV bus will be used as the slack bus for the next iteration.
This may result in the real power output at this generator being
slightly off from the specified values.
Enforcing of generator Q limits inspired by contributions from Mu Lin,
Lincoln University, New Zealand (1/14/05).
@author: Ray Zimmerman (PSERC Cornell)
"""
## default arguments
if casedata is None:
casedata = join(dirname(__file__), 'case9')
ppopt = ppoption(ppopt)
## options
verbose = ppopt["VERBOSE"]
qlim = ppopt["ENFORCE_Q_LIMS"] ## enforce Q limits on gens?
dc = ppopt["PF_DC"] ## use DC formulation?
## read data
ppc = loadcase(casedata)
## add zero columns to branch for flows if needed
if ppc["branch"].shape[1] < QT:
ppc["branch"] = c_[ppc["branch"],
zeros((ppc["branch"].shape[0],
QT - ppc["branch"].shape[1] + 1))]
## convert to internal indexing
ppc = ext2int(ppc)
baseMVA, bus, gen, branch = \
ppc["baseMVA"], ppc["bus"], ppc["gen"], ppc["branch"]
## get bus index lists of each type of bus
ref, pv, pq = bustypes(bus, gen)
## generator info
on = find(gen[:, GEN_STATUS] > 0) ## which generators are on?
gbus = gen[on, GEN_BUS].astype(int) ## what buses are they at?
##----- run the power flow -----
t0 = time()
if verbose > 0:
v = ppver('all')
stdout.write('PYPOWER Version %s, %s' % (v["Version"], v["Date"]))
if dc: # DC formulation
if verbose:
stdout.write(' -- DC Power Flow\n')
## initial state
Va0 = bus[:, VA] * (pi / 180)
## build B matrices and phase shift injections
B, Bf, Pbusinj, Pfinj = makeBdc(baseMVA, bus, branch)
## compute complex bus power injections [generation - load]
## adjusted for phase shifters and real shunts
Pbus = makeSbus(baseMVA, bus, gen).real - Pbusinj - bus[:, GS] / baseMVA
## "run" the power flow
Va = dcpf(B, Pbus, Va0, ref, pv, pq)
## update data matrices with solution
branch[:, [QF, QT]] = zeros((branch.shape[0], 2))
branch[:, PF] = (Bf * Va + Pfinj) * baseMVA
branch[:, PT] = -branch[:, PF]
bus[:, VM] = ones(bus.shape[0])
bus[:, VA] = Va * (180 / pi)
## update Pg for slack generator (1st gen at ref bus)
## (note: other gens at ref bus are accounted for in Pbus)
## Pg = Pinj + Pload + Gs
## newPg = oldPg + newPinj - oldPinj
refgen = zeros(len(ref), dtype=int)
for k in range(len(ref)):
temp = find(gbus == ref[k])
refgen[k] = on[temp[0]]
gen[refgen, PG] = gen[refgen, PG] + (B[ref, :] * Va - Pbus[ref]) * baseMVA
success = 1
else: ## AC formulation
alg = ppopt['PF_ALG']
if verbose > 0:
if alg == 1:
solver = 'Newton'
elif alg == 2:
solver = 'fast-decoupled, XB'
elif alg == 3:
solver = 'fast-decoupled, BX'
elif alg == 4:
solver = 'Gauss-Seidel'
else:
solver = 'unknown'
print(' -- AC Power Flow (%s)\n' % solver)
## initial state
# V0 = ones(bus.shape[0]) ## flat start
V0 = bus[:, VM] * exp(1j * pi/180 * bus[:, VA])
V0[gbus] = gen[on, VG] / abs(V0[gbus]) * V0[gbus]
if qlim:
ref0 = ref ## save index and angle of
Varef0 = bus[ref0, VA] ## original reference bus(es)
limited = [] ## list of indices of gens @ Q lims
fixedQg = zeros(gen.shape[0]) ## Qg of gens at Q limits
repeat = True
while repeat:
## build admittance matrices
Ybus, Yf, Yt = makeYbus(baseMVA, bus, branch)
## compute complex bus power injections [generation - load]
Sbus = makeSbus(baseMVA, bus, gen)
## run the power flow
alg = ppopt["PF_ALG"]
if alg == 1:
V, success, _ = newtonpf(Ybus, Sbus, V0, ref, pv, pq, ppopt)
elif alg == 2 or alg == 3:
Bp, Bpp = makeB(baseMVA, bus, branch, alg)
V, success, _ = fdpf(Ybus, Sbus, V0, Bp, Bpp, ref, pv, pq, ppopt)
elif alg == 4:
V, success, _ = gausspf(Ybus, Sbus, V0, ref, pv, pq, ppopt)
else:
stderr.write('Only Newton''s method, fast-decoupled, and '
'Gauss-Seidel power flow algorithms currently '
'implemented.\n')
## update data matrices with solution
bus, gen, branch = pfsoln(baseMVA, bus, gen, branch, Ybus, Yf, Yt, V, ref, pv, pq)
if qlim: ## enforce generator Q limits
## find gens with violated Q constraints
gen_status = gen[:, GEN_STATUS] > 0
qg_max_lim = gen[:, QG] > gen[:, QMAX]
qg_min_lim = gen[:, QG] < gen[:, QMIN]
mx = find( gen_status & qg_max_lim )
mn = find( gen_status & qg_min_lim )
if len(mx) > 0 or len(mn) > 0: ## we have some Q limit violations
# No PV generators
if len(pv) == 0:
if verbose:
if len(mx) > 0:
print('Gen %d [only one left] exceeds upper Q limit : INFEASIBLE PROBLEM\n' % mx + 1)
else:
print('Gen %d [only one left] exceeds lower Q limit : INFEASIBLE PROBLEM\n' % mn + 1)
success = 0
break
## one at a time?
if qlim == 2: ## fix largest violation, ignore the rest
k = argmax(r_[gen[mx, QG] - gen[mx, QMAX],
gen[mn, QMIN] - gen[mn, QG]])
if k > len(mx):
mn = mn[k - len(mx)]
mx = []
else:
mx = mx[k]
mn = []
if verbose and len(mx) > 0:
for i in range(len(mx)):
print('Gen ' + str(mx[i] + 1) + ' at upper Q limit, converting to PQ bus\n')
if verbose and len(mn) > 0:
for i in range(len(mn)):
print('Gen ' + str(mn[i] + 1) + ' at lower Q limit, converting to PQ bus\n')
## save corresponding limit values
fixedQg[mx] = gen[mx, QMAX]
fixedQg[mn] = gen[mn, QMIN]
mx = r_[mx, mn].astype(int)
## convert to PQ bus
gen[mx, QG] = fixedQg[mx] ## set Qg to binding
for i in range(len(mx)): ## [one at a time, since they may be at same bus]
gen[mx[i], GEN_STATUS] = 0 ## temporarily turn off gen,
bi = gen[mx[i], GEN_BUS] ## adjust load accordingly,
bus[bi, [PD, QD]] = (bus[bi, [PD, QD]] - gen[mx[i], [PG, QG]])
if len(ref) > 1 and any(bus[gen[mx, GEN_BUS], BUS_TYPE] == REF):
raise ValueError('Sorry, PYPOWER cannot enforce Q '
'limits for slack buses in systems '
'with multiple slacks.')
bus[gen[mx, GEN_BUS].astype(int), BUS_TYPE] = PQ ## & set bus type to PQ
## update bus index lists of each type of bus
ref_temp = ref
ref, pv, pq = bustypes(bus, gen)
if verbose and ref != ref_temp:
print('Bus %d is new slack bus\n' % ref)
limited = r_[limited, mx].astype(int)
else:
repeat = 0 ## no more generator Q limits violated
else:
repeat = 0 ## don't enforce generator Q limits, once is enough
if qlim and len(limited) > 0:
## restore injections from limited gens [those at Q limits]
gen[limited, QG] = fixedQg[limited] ## restore Qg value,
for i in range(len(limited)): ## [one at a time, since they may be at same bus]
bi = gen[limited[i], GEN_BUS] ## re-adjust load,
bus[bi, [PD, QD]] = bus[bi, [PD, QD]] + gen[limited[i], [PG, QG]]
gen[limited[i], GEN_STATUS] = 1 ## and turn gen back on
if ref != ref0:
## adjust voltage angles to make original ref bus correct
bus[:, VA] = bus[:, VA] - bus[ref0, VA] + Varef0
ppc["et"] = time() - t0
ppc["success"] = success
##----- output results -----
## convert back to original bus numbering & print results
ppc["bus"], ppc["gen"], ppc["branch"] = bus, gen, branch
results = int2ext(ppc)
## zero out result fields of out-of-service gens & branches
if len(results["order"]["gen"]["status"]["off"]) > 0:
results["gen"][ix_(results["order"]["gen"]["status"]["off"], [PG, QG])] = 0
if len(results["order"]["branch"]["status"]["off"]) > 0:
results["branch"][ix_(results["order"]["branch"]["status"]["off"], [PF, QF, PT, QT])] = 0
if fname:
fd = None
try:
fd = open(fname, "a")
except Exception as detail:
stderr.write("Error opening %s: %s.\n" % (fname, detail))
finally:
if fd is not None:
printpf(results, fd, ppopt)
fd.close()
else:
printpf(results, stdout, ppopt)
## save solved case
if solvedcase:
savecase(solvedcase, results)
return results, success
if __name__ == '__main__':
runpf()