PPS above 11V exits after 5 seconds of triggering #4

Closed
sakura-ushio opened this issue Aug 16, 2021 · 2 comments
Closed

PPS above 11V exits after 5 seconds of triggering #4

sakura-ushio opened this issue Aug 16, 2021 · 2 comments

Comments

@sakura-ushio
Copy link

My charger supports 5-20V 5A PPS, but it will exit PPS 5 seconds after triggering PPS above 11v. Why?

@ryan-ma
Copy link
Owner

ryan-ma commented Aug 24, 2021

Hi, I just realize a bug that may related to your problem.
The power_data_obj[] array in PD_protocol_t should be size of 7 instead of 6, which will cause power negotiation fail or even crash if number of PDO is more than 6.
I pushed the fix. See if this can solve your issue.

@sakura-ushio
Copy link
Author

Now the PPS above 11V works perfectly.