You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
I think the parameter 'accept' in the dual annealing function has a wrong default value and wrong acceptable bounds. As explained in this paper Tsallis C, Stariolo DA. Generalized Simulated Annealing. Physica A, 233, 395-406 (1996), the acceptance parameter should be above 1 (probably slightly above to be close to classic simulated annealing).
The descrition for this parameter is actually :
"""Parameter for acceptance distribution. It is used to control the probability of acceptance. The lower the acceptance parameter, the smaller the probability of acceptance. Default value is -5.0 with a range (-1e4, -5]."""
Without an acceptable parameter here the algorithms never accepts states of higher energy and the algorithms does not behave as expected.
many thanks
The text was updated successfully, but these errors were encountered:
Hello,
I think the parameter 'accept' in the dual annealing function has a wrong default value and wrong acceptable bounds. As explained in this paper Tsallis C, Stariolo DA. Generalized Simulated Annealing. Physica A, 233, 395-406 (1996), the acceptance parameter should be above 1 (probably slightly above to be close to classic simulated annealing).
The descrition for this parameter is actually :
"""Parameter for acceptance distribution. It is used to control the probability of acceptance. The lower the acceptance parameter, the smaller the probability of acceptance. Default value is -5.0 with a range (-1e4, -5]."""
Without an acceptable parameter here the algorithms never accepts states of higher energy and the algorithms does not behave as expected.
many thanks
The text was updated successfully, but these errors were encountered: