Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Change Buck to TPS546D24ARVFR #154

Closed
benjamin-wilson opened this issue Apr 14, 2024 · 2 comments
Closed

Change Buck to TPS546D24ARVFR #154

benjamin-wilson opened this issue Apr 14, 2024 · 2 comments
Assignees
Labels
402 include in v402

Comments

@benjamin-wilson
Copy link
Collaborator

https://webench.ti.com/appinfo/webench/scripts/SDP.cgi?ID=42BF472B95D37383

17A should be sufficient, changing to this buck should allow removal of INA260, DS4432U and EMC2101.

@weixiongmei
Copy link

@benjamin-wilson what's minimum current does the BM1366 needs?

@skot skot self-assigned this Apr 25, 2024
@skot skot added the 402 include in v402 label Apr 25, 2024
@skot
Copy link
Owner

skot commented Apr 25, 2024

added in b9c48b8

@skot skot closed this as completed Jun 7, 2024
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment