Wemos D1 Mini
MPP Solar PIP5048MG does not accept commands MUCHGC0xx and MCHGC0xx
none
No response
1.x.x and above
{"EspData":{"Device_name":"Solar2MQTT","ESP_VCC":2.965,"Wifi_RSSI":-45,"sw_version":"1.1.6","Free_Heap":23512,"HEAP_Fragmentation":21,"json_memory_usage":1102},"DeviceData":{"AC_in_rating_voltage":220,"AC_in_rating_current":22.7,"AC_out_rating_voltage":220,"AC_out_rating_frequency":50,"AC_out_rating_current":22.7,"AC_out_rating_apparent_power":5000,"AC_out_rating_active_power":5000,"Battery_rating_voltage":48,"Battery_re-charge_voltage":44,"Battery_under_voltage":42,"Battery_bulk_voltage":57.8,"Battery_float_voltage":57.8,"Battery_type":"User","Current_max_AC_charging_current":10,"Current_max_charging_current":60,"Input_voltage_range":"UPS","Output_source_priority":"Utility first","Charger_source_priority":"Utility first","Parallel_max_num":9,"Machine_type":"Off Grid","Topology":"Transformerless","Output_mode":0,"Battery_re-discharge_voltage":48,"PV_OK_condition_for_parallel":0,"PV_power_balance":1,"Max_charging_time_at_CV_stage":0,"Protocol_ID":"PI30"},"LiveData":{"AC_in_Voltage":218.3,"AC_in_Frequenz":50,"AC_out_Voltage":218.3,"AC_out_Frequenz":50,"AC_out_VA":5248,"AC_out_Watt":5248,"AC_out_percent":104,"Inverter_Bus_Voltage":424,"Battery_Voltage":57.8,"Battery_Charge_Current":0,"Battery_Percent":100,"Inverter_Bus_Temperature":36,"PV_Input_Current":0,"PV_Input_Voltage":0,"Battery_SCC_Volt":0,"Battery_Discharge_Current":0,"Status_Flag":10101,"Battery_voltage_offset_fans_on":0,"EEPROM_Version":0,"PV_Charging_Power":0,"Device_Status":110,"Battery_Load":0,"PV_Input_Power":0,"Inverter_Operation_Mode":"Line"}}
Chrome
The text was updated successfully, but these errors were encountered:
Did you enter it as three-digit? You have only entered two digits (xx) here.
The inverter expects the value to be three digits.
Sorry, something went wrong.
The inverter accepted commands with three-digit values. For example MUCHGC0050 or MCHGC0050. Thanks for the help
No branches or pull requests
Is there an existing issue for this?
Used Hardware?
Wemos D1 Mini
What happened?
MPP Solar PIP5048MG does not accept commands MUCHGC0xx and MCHGC0xx
Screenshots / Fotos
none
Steps To Reproduce
No response
Version
1.x.x and above
Relevant livejson output
What browsers are you seeing the problem on?
Chrome
The text was updated successfully, but these errors were encountered: