Notifications
You must be signed in to change notification settings - Fork 2
/
nosetests_details.txt
105 lines (88 loc) · 2.95 KB
/
nosetests_details.txt
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
________tk_nosy UNITTEST RUN# 8_________
{Item #1} test_dHvap_N2,
ERROR in dHvap P=1000, Pc=492.519
{Item #2} test_dHvap_O2,
ERROR in dHvap P=1000, Pc=731.425
{Item #3} test_getSatP_N2,
ERROR... getSatP called with T>Tc. T=None, Tc=227.146
{Item #4} test_getSatP_O2,
ERROR... getSatP called with T>Tc. T=None, Tc=278.246
{Item #5} test_getSatPandDens_N2,
ERROR... getSatP called with T>Tc. T=None, Tc=227.146
{Item #6} test_getSatPandDens_O2,
ERROR... getSatP called with T>Tc. T=None, Tc=278.246
{Item #7} test_getSatT_N2,
ERROR... getSatT called with P>Pc. P=None, Pc=492.519
{Item #8} test_getSatT_O2,
ERROR... getSatT called with P>Pc. P=None, Pc=731.425
ERROR... getSatT called with P>Pc. P=None, Pc=731.425
{Item #9} test_getSatTandDens_N2,
ERROR... getSatT called with P>Pc. P=None, Pc=492.519
{Item #10} test_getSatTandDens_O2,
ERROR... getSatT called with P>Pc. P=None, Pc=731.425
{Item #11} test_printCriticalProps_N2,
Critical Properties for fluid Nitrogen (N2)
Tc= 227.146 degR
Tnbp= 139.239 degR
Pc = 492.519 psia
Dc = 19.5587 lbm/cu ft
MW= 28.0135 lbm/lbmmole
Zc =0.289458 (-)
Hc = 12.5678 BTU/lbm
Ec = 7.9079 BTU/lbm
Sc = 1.00671 BTU/lbm degR
Ac = 444.365 ft/sec
Vc =0.0382286 viscosity [1.0E5 * lbm/ft-sec]
Cc = 886.461 thermal conductivity [BTU/ft-hr-R]
{Item #12} test_printCriticalProps_O2,
Critical Properties for fluid Oxygen (O2)
Tc= 278.246 degR
Tnbp= 162.338 degR
Pc = 731.425 psia
Dc = 27.2276 lbm/cu ft
MW= 31.9988 lbm/lbmmole
Zc =0.287943 (-)
Hc = 13.9393 BTU/lbm
Ec = 8.96846 BTU/lbm
Sc = 1.00335 BTU/lbm degR
Ac = 502.502 ft/sec
Vc = nan viscosity [1.0E5 * lbm/ft-sec]
Cc =0.0221309 thermal conductivity [BTU/ft-hr-R]
{Item #13} test_printProps_N2,
State Point for fluid Nitrogen (N2)
T = 530 degR (Tc= 227.146 , Tnbp= 139.239 Ttriple= 113.672 )
P = 1000 psia (Pc= 492.519 )
D = 4.94659 lbm/cu ft (Dc= 19.5587 )
E = 87.6731 BTU/lbm
H = 125.083 BTU/lbm
S = 1.31927 BTU/lbm degR
Cv=0.181367 BTU/lbm degR
Cp=0.275948 BTU/lbm degR
g = 1.52149 Cp/Cv (-)
A = 1198.41 ft/sec
V =0.039545 viscosity [1.0E5 * lbm/ft-sec]
C =0.0167546 thermal conductivity [BTU/ft-hr-R]
MW= 28.0135 lbm/lbmmole
Q = -1 Vapor Quality (mass fraction gas)
Z =0.995923 (-)
{Item #14} test_printProps_O2,
State Point for fluid Oxygen (O2)
T = 530 degR (Tc= 278.246 , Tnbp= 162.338 Ttriple= 97.8498 )
P = 1000 psia (Pc= 731.425 )
D = 5.86053 lbm/cu ft (Dc= 27.2276 )
E = 76.198 BTU/lbm
H = 107.774 BTU/lbm
S = 1.25462 BTU/lbm degR
Cv=0.161096 BTU/lbm degR
Cp=0.247971 BTU/lbm degR
g = 1.53928 Cp/Cv (-)
A = 1085.38 ft/sec
V =0.0458861 viscosity [1.0E5 * lbm/ft-sec]
C =0.0170064 thermal conductivity [BTU/ft-hr-R]
MW= 31.9988 lbm/lbmmole
Q = -1 Vapor Quality (mass fraction gas)
Z = 0.9602 (-)
{Item #15} test_printTPD_N2,
N2 T= 530.0 P=1000.0 D=4.9466 E= 87.67 H=125.08 S=1.319 Q=-1.00
{Item #16} test_printTPD_O2,
O2 T= 530.0 P=1000.0 D=5.8605 E= 76.20 H=107.77 S=1.255 Q=-1.00