There is a total of four OIDs that make up a 128 bit wide field, with each bit representing a particular fault. Each of the OIDs contains 32 bits. If no bits are set (i.e. the four OIDs return 0), no fault is present.
fault[0].flt |
Bits 0 to 31 |
fault[1].flt |
Bits 32 to 63 |
fault[2].flt |
Bits 64 to 95 |
fault[3].flt |
Bots 96 to 127 |
The table lists known faults, if the bit is set in the devices output then the fault is currently present:
Bit | Description |
---|---|
0 | TRAP occured |
1 | RTC can't be configured |
2 | RTC 1Hz signal timeout |
3 | Hardware Stop by 3.3V fault |
4 | Hardware Stop by PWM Logic |
5 | Hardware Stop by Uzk overvoltage |
6 | Uzk+ is above limit |
7 | Uzk- is above limit |
8 | Throttle phase L1 overcurrent |
9 | Throttle phase L2 overcurrent |
10 | Throttle phase L3 overcurrent |
11 | Buffer capacitor voltage |
12 | Quartz fault |
13 | Grid under-voltage phase 1 |
14 | Grid under-voltage phase 2 |
15 | Grid under-voltage phase 3 |
16 | Battery overcurrent |
17 | Relais test failed |
18 | Board overtemperature |
19 | Core overtemperature |
20 | (Heat)Sink 1 overtemperature |
21 | (Heat)Sink 2 overtemperature |
22 | Error in I2C communication with Power Board |
23 | Power Board error |
24 | PWM output ports defective |
25 | Insulation to small or not plausible |
26 | I DC component max (1A) |
27 | I DC component max slow (47mA) |
28 | Possible defect in one of the DSD channels (current offset too large) |
29 | Error in RS485 communication with Relais Box IGBT L1 BH defective |
30 | Phase to phase overvoltage |
31 | IGBT L1 BH defective |
32 | IGBT L1 BL defective |
33 | IGBT L2 BH defective |
34 | IGBT L2 BL defective |
35 | IGBT L3 BH defective |
36 | IGBT L3 BL defective |
37 | Long-term overvoltage phase 1 |
38 | Long-term overvoltage phase 2 |
39 | Long-term overvoltage phase 3 |
40 | Overvoltage phase 1, level 1 |
41 | Overvoltage phase 1, level 2 |
42 | Overvoltage phase 2, level 1 |
43 | Overvoltage phase 2, level 2 |
44 | Overvoltage phase 3, level 1 |
45 | Overvoltage phase 3, level 2 |
46 | Overfrequency, level 1 |
47 | Overfrequency, level 2 |
48 | Undervoltage phase 1, level 1 |
49 | Undervoltage phase 1, level 2 |
50 | Undervoltage phase 2, level 1 |
51 | Undervoltage phase 2, level 2 |
52 | Undervoltage phase 3, level 1 |
53 | Undervoltage phase 3, level 2 |
54 | Underfrequency, level 1 |
55 | Underfrequency, level 2 |
56 | CPU exception NMI |
57 | CPU exception HardFault |
58 | CPU exception MemManage |
59 | CPU exception BusFault |
60 | CPU exception UsageFault |
61 | RTC Power on reset |
62 | RTC Oscillation stops |
63 | RTC Supply voltage drop |
64 | Jump of RCD current DC + AC > 30mA was noticed |
65 | Jump of RCD current DC > 60mA was noticed |
66 | Jump of RCD current AC > 150mA was noticed |
67 | RCD current > 300mA was notices |
68 | Incorrect +5V was noticed |
69 | Incorrect -9V was noticed |
70 | Incorrect +9V was noticed |
71 | Incorrect +3V3 was noticed |
72 | Failure of RDC calibration was noticed |
73 | Failure of I2C was noticed |
74 | afi frequency generator failure |
75 | (Heat)sink temperature too high |
76 | Uzk is over limit |
77 | Usg A is over limit |
78 | Usg B is over limit |
79 | Switching On Conditions Umin phase 1 |
80 | Switching On Conditions Umax phase 1 |
81 | Switching On Conditions Fmin phase 1 |
82 | Switching On Conditions Fmax phase 1 |
83 | Switching On Conditions Umin phase 2 |
84 | Switching On Conditions Umax phase 2 |
85 | Battery current sensor defective |
86 | Battery booster damaged |
87 | Switching On Conditions Umin phase 3 |
88 | Switching On Conditions Umax phase 3 |
89 | Voltage surge or average offset is too large on AC-terminals (phase failure detected) |
90 | Inverter is disconnected from the household grid |
91 | Difference of the measured +9V between DSP and PIC is too large |
92 | 1.5V error |
93 | 2.5V error |
94 | 1.5V measurement difference |
95 | 2.5V measurement difference |
96 | The battery voltage is outside of the expected range |
97 | Unable to start the main PIC software |
98 | PIC bootloader detected unexpectedly |
99 | Phase position error (not 120° as expected) |
100 | Battery overvoltage |
101 | Throttle current is unstable |
102 | Difference between internally and externally measured grid voltage is too large in phase 1 |
103 | Difference between internally and externally measured grid voltage is too large in phase 2 |
104 | Difference between internally and externally measured grid voltage is too large in phase 3 |
105 | External emergency turn-off signal is active |
106 | Battery is empty, not enough energy for standby |
107 | CAN communication timeout with battery |
108 | Timing problem |
109 | Battery IGBT's heat sink overtemperature |
110 | Battery heat sink temperature too high |
111 | Internal relais box error |
112 | Relais box PE off error |
113 | Relais box PE on error |
114 | Internal battery error |
115 | Parameter changed |
116 | 3 attempts of island building are failing |
117 | Phase to phase undervoltage |
118 | System reset detected |
119 | Update detected |
120 | FRT overvoltage |
121 | FRT undervoltage |
122 | IGBT L1 free-wheeling diode defective |
123 | IGBT L2 free-wheeling diode defective |
124 | IGBT L3 free-wheeling diode defective |
125 | Single-phase mode is activated but not allowed for this device class (e.g. 10K) |
126 | Island detected |