You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Hi @harryzz - late response, thanks for the data for the PC1565, added to the decoding and list of verified panels. Also thanks for the 0xEF data, the develop branch actually already had this but still hadn't been pushed out to master.
Hello
some additional data for DSC PC1565 panel.
4704.33: 00010110 0 00001110 00100010 11100110 00101100 [0x16] Unknown panel | Zone wiring: EOL | *8 programming
also in installation mode in section [903] Module Supervision Field:
19035.68: 00000101 0 10000001 11101111 10010001 11000111 [0x05] Partition 1: Ready Backlight - Unrecognized data: 0xEF | Partition 2: disabled
19035.75: 00001010 0 10000001 11101111 01000001 00000000 00000000 00000000 00000000 10111011 [0x0A] Ready Backlight - Unrecognized data: 0xEF | Zone lights: 1 7
br
Zahari
The text was updated successfully, but these errors were encountered: