Only 5 Hoymiles mikro inverters can be checked for inverter info #814

Closed
baba-joe opened this issue Apr 17, 2023 · 9 comments
Closed

Only 5 Hoymiles mikro inverters can be checked for inverter info #814

baba-joe opened this issue Apr 17, 2023 · 9 comments
Labels
bug Something isn't working

Comments

@baba-joe
Copy link

What happened?

If more than 5 Hoymiles inverters are added inverter info can only be retrieved for the first 5 inverters. The 6th will give an error message in a window reading "No Information available Did not receive any valid data from the inverter till now. Still trying..." and the 7th shows a rotating open circle...

To Reproduce Bug

Add more than 5 Hoymiles mikro inverters.

Expected Behavior

Since the documentation claims that 10 inverters are supportet I would expect to be able to retrieve inverter info for all 10 possible inverters.

Install Method

Pre-Compiled binary from GitHub

What git-hash/version of OpenDTU?

v23.4.15

Relevant log/trace output

No response

Anything else?

I happen to have 10 Hoymile mikro inverters available for testing in case you are interested?

@baba-joe baba-joe added the bug Something isn't working label Apr 17, 2023
@tbnobody
Copy link
Owner

tbnobody commented Apr 17, 2023

After adding the inverters, how long did you wait until you pressed the inverter info button?

A output of the serial console would also be helpfull

@baba-joe
Copy link
Author

baba-joe commented Apr 17, 2023

I have added them a day ago but still the same behaviour. Also I have tried to swap inverters by removing some and keeping the ones not showing info added. It always works OK with 5 or less inverters but as soon as I add a 6th it is not possible to retrieve info. How to I have to use the console to get the output you need? It seems to be not possible to keep the console open while trying to retrieve inverter info? The first 5 inverters are still showing inverter info OK, the issue only starts past the 5th.

@baba-joe
Copy link
Author

@tbnobody
Copy link
Owner

The issue was automatically closed. Please doublecheck whether it's fixed now

@baba-joe
Copy link
Author

No, how would it?
openDTU_no_inverter_info02
openDTU_no_inverter_info01

@tbnobody
Copy link
Owner

tbnobody commented Apr 18, 2023

No, how would it?

Which version are you running? I see that the data age for this inverter is 67000 seconds... That means 18hours.... But the release with the fix is <12h old...

@tbnobody tbnobody reopened this Apr 18, 2023
@baba-joe
Copy link
Author

still 23.4.15

was not aware about an update and waiting for your response

let me check after I pushed 23.4.17

@baba-joe
Copy link
Author

baba-joe commented Apr 18, 2023

now I can retrieve info for all 7, very nice, thanks!

if just the sun would show, what a spring this year in Ostbayern

Copy link

github-actions bot commented Apr 5, 2024

This issue has been automatically locked since there has not been any recent activity after it was closed. Please open a new discussion or issue for related concerns.

@github-actions github-actions bot locked as resolved and limited conversation to collaborators Apr 5, 2024
Sign up for free to subscribe to this conversation on GitHub. Already have an account? Sign in.
Labels
bug Something isn't working
Projects
None yet
Development

No branches or pull requests

2 participants