IPC7351 and IEC 61188-7 Level A component orientation must be respected.
The user-provided orientation compatible with the datasheet is used to generate
correct pad numbers from the orientation of the drawing. However, the final
drawn footprint must always have pin A1 in the upper left (North West).
The BGA grid generator should be modified to insure this is true by rotating
the generated grid appropriately.
Original issue reported on code.google.com by tennesse...@gmail.com on 4 Feb 2011 at 7:35
The text was updated successfully, but these errors were encountered:
Attached a drawing of what is meant. This is from the "PCB Design Perfection
Starts in the CAD Library - Part 10" blog post from Tom Hausherr
(http://blogs.mentor.com/tom-hausherr/blog/2011/01/14/pcb-design-perfection-star
ts-in-the-cad-library-part-10/)
Original comment by tennesse...@gmail.com on 4 Feb 2011 at 7:36