; Filename: mfunc55.mac - To run from VCP AUX 10 key, set p197 = 5511
; M55 macro
; Description: User Customizable Macro
; Notes:
; Requires: Machine home must be set prior to use.
; Please see TB300 for tips on writing custom macros.
;------------------------------------------------------------------------------
IF #50010 ;Prevent lookahead from parsing past here
IF #4201 || #4202 THEN GOTO 1000 ;Skip macro if graphing or searching
M225 #100 "Work zero will be set to Machine X,Y Coordinates 8.8986,10.8212. Press Cycle Start to Continue"
N100 ;Insert your code between N100 and N1000
G28 ;Go to Home Position
G91 ;Incremental mode
G00 X8.8986 Y10.8212 ;Rapid to machine coords 8.8986,10.8212
G92 X0 Y0 ;Set work zero to 0,0 at machine coords 8.8986,10.8212
;---------Example Macro for a Manual Lube Pump Aux Key--------------------------------------
; This Macro will activate the LubePump Logic in PLC and will keep pump on based on Parameter 179.
; Example: Parameter 179 = 1015, Then when this macro is activated the LubePump will have power ON for 15 seconds.
; A “ Lube pump Turn Off” Macro (M95) is not needed as the PLC resets the output in the logic when the ON timer is finished.
; Each time this m code is issued the “G-code running” timer is reset, so in our example P179=1015. After the pump has run for 15
; seconds the “G code running” timer begins again to count down 10 minutes before the next automatic lube cycle.
; This macro can be used during a G code program, for example if the user wishes to pump some extra lube while the job is running.
; Uncomment the M94 Line Below to set Aux 8 VCP Aux key as a manual lube pump one shot button.
; This will set "SV_M94_M95_8" in the PLC, which a system variable used for lube pump operation that is pre-coded in the PLC.
;M94 /8 ;M94 Requests to SET "ManualLubePump" in PLC.
;------------------------------End of Example--------------------------------------------------
;------------------Example Macro for PopUpPins Output---------------------------
;Use Aux 8 and Aux 9 to Turn on and Off PopUpPins Output
;M94 is used to Turn on a variable in PLC which in turn activates logic in the PLC
;M95 is used to Turn Off the variable
;Remove the ";" infront of code below in mfunc55 and mfunc56 to use
;M94 /30 ;Turn on PopUpPins
;------------------------------End of Example-------------------------------------------
;-----------------Example Macro for SpindleCooling Output---------------------------
;Uses Aux 8 and Aux 9 to Turn On and Off the SpindleCooling Output
;M94 is used to Turn on a variable in PLC which in turn activates logic in the PLC
;M95 is used to Turn Off the variable
;Remove the ";" infront of the code below in both mfunc55 and mfunc56 to use
;M94 /31 ;Turn on SpindleCooling
;------------------------------End of Example-------------------------------------------
N1000 ;End of Macro