Marlin M105 Response Incorrect #21

Open
kva19 opened this issue Apr 20, 2021 · 1 comment
Open

Marlin M105 Response Incorrect #21

kva19 opened this issue Apr 20, 2021 · 1 comment

Comments

@kva19
Copy link

kva19 commented Apr 20, 2021

So I have been trying to figure out why my octoprint doesn't get a temp update from my printer and after quite a bit of trial and error I have figured out it is because the M105 format is not correct. The second nozzle temp is never returned. Only way to get the second nozzle temp is by manually changing to the second extruder and changing back but the second you change back the nozzle temp for the second extruder does not update. Could anyone help me in correcting this issue?

Current format is

Send: M105
Recv: ok T:16.9 /0.0 B:16.9 /0.0 @:0 B@:0

The correct format should be

Send M105
Recv: ok T:16.9 /0.0 T1:16.9 /0.0 B:10 /0.0

The T is referring to extruder 1 and t1 is referring to extruder 2

@blixem
Copy link

blixem commented Jun 1, 2021

Adding request for this update as well please.