/
events.dm
80 lines (69 loc) · 2.6 KB
/
events.dm
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
/proc/power_failure()
priority_announce("Abnormal activity detected in [station_name()]'s powernet. As a precautionary measure, the station's power will be shut off for an indeterminate duration.", "Critical Power Failure", 'sound/ai/poweroff.ogg')
for(var/obj/machinery/power/smes/S in GLOB.machines)
if(istype(get_area(S), /area/ai_monitored/turret_protected) || !(S.z in GLOB.station_z_levels))
continue
S.charge = 0
S.output_level = 0
S.output_attempt = 0
S.update_icon()
S.power_change()
var/list/skipped_areas = list(/area/engine/engineering, /area/engine/supermatter, /area/engine/atmospherics_engine, /area/ai_monitored/turret_protected/ai)
for(var/area/A in world)
if( !A.requires_power || A.always_unpowered )
continue
var/skip = 0
for(var/area_type in skipped_areas)
if(istype(A,area_type))
skip = 1
break
if(A.contents)
for(var/atom/AT in A.contents)
if(!(AT.z in GLOB.station_z_levels)) //Only check one, it's enough.
skip = 1
break
if(skip) continue
A.power_light = FALSE
A.power_equip = FALSE
A.power_environ = FALSE
A.power_change()
for(var/obj/machinery/power/apc/C in GLOB.apcs_list)
if(C.cell && (C.z in GLOB.station_z_levels))
var/area/A = C.area
var/skip = 0
for(var/area_type in skipped_areas)
if(istype(A,area_type))
skip = 1
break
if(skip) continue
C.cell.charge = 0
/proc/power_restore()
priority_announce("Power has been restored to [station_name()]. We apologize for the inconvenience.", "Power Systems Nominal", 'sound/ai/poweron.ogg')
for(var/obj/machinery/power/apc/C in GLOB.machines)
if(C.cell && (C.z in GLOB.station_z_levels))
C.cell.charge = C.cell.maxcharge
C.failure_timer = 0
for(var/obj/machinery/power/smes/S in GLOB.machines)
if(!(S.z in GLOB.station_z_levels))
continue
S.charge = S.capacity
S.output_level = S.output_level_max
S.output_attempt = 1
S.update_icon()
S.power_change()
for(var/area/A in world)
if(!istype(A, /area/space) && !istype(A, /area/shuttle) && !istype(A, /area/arrival))
A.power_light = TRUE
A.power_equip = TRUE
A.power_environ = TRUE
A.power_change()
/proc/power_restore_quick()
priority_announce("All SMESs on [station_name()] have been recharged. We apologize for the inconvenience.", "Power Systems Nominal", 'sound/ai/poweron.ogg')
for(var/obj/machinery/power/smes/S in GLOB.machines)
if(!(S.z in GLOB.station_z_levels))
continue
S.charge = S.capacity
S.output_level = S.output_level_max
S.output_attempt = 1
S.update_icon()
S.power_change()