You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Running SNMPCollector v 0.13.1 in a docker container.
I have a Cumulus Linux device configured to collect interface stats however the device never gets connected nor starts collecting stats. If I use the test function and manually walk the relevant MIB's they all are successful and return within 0.2s
Logs for my failed device appear to show SNMP timing out.
time="2023-04-25 18:50:30" level=info msg="Got basic system info snmp.SysInfo{SysDescr:"Cumulus Linux 3.7.12 (Linux Kernel 4.1.33-1+cl3u26)", SysUptime:1010228000000000, SysContact:"root", SysName:"testswitch", SysLocation:"Unknown"} " device=10.10.0.87 measurement=ifMIB
time="2023-04-25 18:50:30" level=info msg="Loading Indexed values" device=10.10.0.87 measurement=ifMIB
time="2023-04-25 18:50:30" level=debug msg="Looking up column names .1.3.6.1.2.1.2.2.1.2 " device=10.10.0.87 measurement=ifMIB
time="2023-04-25 18:51:30" level=info msg="[device] STATS SEND NOT CONNECTED"
time="2023-04-25 18:52:30" level=info msg="[device] STATS SEND NOT CONNECTED"
time="2023-04-25 18:52:30" level=error msg="LOADINDEXEDLABELS - SNMP WALK error: request timeout (after 5 retries)" device=10.10.0.87 measurement=ifMIB
time="2023-04-25 18:52:30" level=error msg="Not able to initialize at the start of the measurement: trying to load Indexed Labels for baseOid .1.3.6.1.2.1.2.2.1.2: request timeout (after 5 retries)" device=10.10.0.87 measurement=ifMIB
time="2023-04-25 18:52:30" level=info msg="MeasurementLoop Init Loop Align...." device=10.10.0.87 measurement=ifMIB
time="2023-04-25 18:52:30" level=info msg="Waiting 29.307442161s to round until nearest interval... (Cycle = 60 seconds)" device=10.10.0.87 measurement=ifMIB
time="2023-04-25 18:53:00" level=info msg="MeasurementLoop new Iteration" device=10.10.0.87 measurement=ifMIB
time="2023-04-25 18:53:00" level=info msg="Loading Indexed values" device=10.10.0.87 measurement=ifMIB
time="2023-04-25 18:53:00" level=debug msg="Looking up column names .1.3.6.1.2.1.2.2.1.2 " device=10.10.0.87 measurement=ifMIB
time="2023-04-25 18:53:30" level=info msg="[device] STATS SEND NOT CONNECTED"
The text was updated successfully, but these errors were encountered:
Running SNMPCollector v 0.13.1 in a docker container.
I have a Cumulus Linux device configured to collect interface stats however the device never gets connected nor starts collecting stats. If I use the test function and manually walk the relevant MIB's they all are successful and return within 0.2s
Logs for my failed device appear to show SNMP timing out.
time="2023-04-25 18:50:30" level=info msg="Got basic system info snmp.SysInfo{SysDescr:"Cumulus Linux 3.7.12 (Linux Kernel 4.1.33-1+cl3u26)", SysUptime:1010228000000000, SysContact:"root", SysName:"testswitch", SysLocation:"Unknown"} " device=10.10.0.87 measurement=ifMIB
time="2023-04-25 18:50:30" level=info msg="Loading Indexed values" device=10.10.0.87 measurement=ifMIB
time="2023-04-25 18:50:30" level=debug msg="Looking up column names .1.3.6.1.2.1.2.2.1.2 " device=10.10.0.87 measurement=ifMIB
time="2023-04-25 18:51:30" level=info msg="[device] STATS SEND NOT CONNECTED"
time="2023-04-25 18:52:30" level=info msg="[device] STATS SEND NOT CONNECTED"
time="2023-04-25 18:52:30" level=error msg="LOADINDEXEDLABELS - SNMP WALK error: request timeout (after 5 retries)" device=10.10.0.87 measurement=ifMIB
time="2023-04-25 18:52:30" level=error msg="Not able to initialize at the start of the measurement: trying to load Indexed Labels for baseOid .1.3.6.1.2.1.2.2.1.2: request timeout (after 5 retries)" device=10.10.0.87 measurement=ifMIB
time="2023-04-25 18:52:30" level=info msg="MeasurementLoop Init Loop Align...." device=10.10.0.87 measurement=ifMIB
time="2023-04-25 18:52:30" level=info msg="Waiting 29.307442161s to round until nearest interval... (Cycle = 60 seconds)" device=10.10.0.87 measurement=ifMIB
time="2023-04-25 18:53:00" level=info msg="MeasurementLoop new Iteration" device=10.10.0.87 measurement=ifMIB
time="2023-04-25 18:53:00" level=info msg="Loading Indexed values" device=10.10.0.87 measurement=ifMIB
time="2023-04-25 18:53:00" level=debug msg="Looking up column names .1.3.6.1.2.1.2.2.1.2 " device=10.10.0.87 measurement=ifMIB
time="2023-04-25 18:53:30" level=info msg="[device] STATS SEND NOT CONNECTED"
The text was updated successfully, but these errors were encountered: