Multi-Bit Binary Output Record (mbbo)

The normal use for the mbbo record type is to send a binary value (representing one of up to 16 states) to a Digital Output module. It is used for any device that uses more than one contiguous bit to control it. The mbbo record can also be used to write discrete values to other records via database or channel access links.

Parameter Fields

The record-specific fields are described below, grouped by functionality.

Scan Parameters

The mbbo record has the standard fields for specifying under what circumstances it will be processed. These fields are listed in Scan Fields.

Desired Output Parameters

The multi-bit binary output record, like all output records, must specify where its output originates. The output mode select (OMSL) field determines whether the output originates from another record or from database access (i.e., the operator). When set to closed_loop, the desired output is retrieved from the link specified in the desired output (DOL) field--which can specify either a database or channel access link--and placed into the VAL field. When set to supervisory, the DOL field is ignored and the current value of VAL is simply written. VAL can be changed via dpPuts at run-time when OMSL is supervisory. The DOL field can also be a constant, in which case the VAL field is initialized to the constant value. If DOL is a constant, OMSL cannot be set to closed_loop.

The VAL field itself usually consists of an index that specifies one of the states. The actual output written is the value of RVAL, which is converted from VAL following the routine explained in the next section. However, records that use the Soft Channel device support module write the VAL field's value without any conversion.

Field Summary Type DCT Default Read Write CA PP
OMSL Output Mode Select MENU menuOmsl Yes Yes Yes No
DOL Desired Output Link INLINK Yes Yes Yes No
VAL Desired Value ENUM Yes Yes Yes Yes

Convert and Write Parameters

The device support routines write the desired output to the location specified in the OUT field. If the record uses soft device support, OUT can contain a constant, a database link, or a channel access link; however, if OUT is a constant, no value will be written.

For records that write their values to hardware devices, the OUT output link must specify the address of the I/O card, and the DTYP field must specify the corresponding device support module. Be aware that the address format differs according to the I/O bus used.

For mbbo records that write to hardware, the value written to the output location is the value contained in RVAL, which is converted from VAL, VAL containing an index of one of the 16 states (0-15). RVAL is then set to the corresponding state value, the value in one of the fields ZRVL through FFVL. Then this value is shifted left according to the number in the SHFT field so that the value is in the correct position for the bits being used (the SHFT value is set by device support and is not configurable by the user).

The state value fields ZRVL through FFVL must be configured by the user before run-time. When the state values are not defined, the states defined (SDEF) field is set to FALSE at initialization time by the record routines. When SDEF is FALSE, then the record processing routine does not try to find a match, RVAL is set equal to VAL, the bits are shifted using the number in SHFT, and the value is written thus.

If the OUT output link specifies a database link, channel access link, or constant, then the DTYP field must specify either one of the two soft device support modules-- Soft Channel or Raw Soft Channel. Soft Channel writes the value of VAL to the output link, without any conversion, while Raw Soft Channel writes the value from RVAL after it has undergone the above conversion.

Note also that when a string is retrieved as the desired output, a record support routine is provided (put_enum_str()) that will check to see if the string matches one of the strings in the ZRST through FFST fields. If a match is found, RVAL is set equal to the corresponding state value of that string.

Field Summary Type DCT Default Read Write CA PP
OUT Output Specification OUTLINK Yes Yes Yes No
DTYP Device Type DEVICE Yes Yes Yes No
RVAL Raw Value ULONG No Yes Yes Yes
SHFT Shift USHORT Yes Yes Yes No
SDEF States Defined SHORT No Yes No No
ZRVL Zero Value ULONG Yes Yes Yes Yes
ONVL One Value ULONG Yes Yes Yes Yes
TWVL Two Value ULONG Yes Yes Yes Yes
THVL Three Value ULONG Yes Yes Yes Yes
FRVL Four Value ULONG Yes Yes Yes Yes
FVVL Five Value ULONG Yes Yes Yes Yes
SXVL Six Value ULONG Yes Yes Yes Yes
SVVL Seven Value ULONG Yes Yes Yes Yes
EIVL Eight Value ULONG Yes Yes Yes Yes
NIVL Nine Value ULONG Yes Yes Yes Yes
TEVL Ten Value ULONG Yes Yes Yes Yes
ELVL Eleven Value ULONG Yes Yes Yes Yes
TVVL Twelve Value ULONG Yes Yes Yes Yes
TTVL Thirteen Value ULONG Yes Yes Yes Yes
FTVL Fourteen Value ULONG Yes Yes Yes Yes
FFVL Fifteen Value ULONG Yes Yes Yes Yes

Operator Display Parameters

These parameters are used to present meaningful data to the operator. These fields are used to display the value and other parameters of the mbbo record either textually or graphically. The ZRST-FFST fields contain strings describing each of the corresponding states. The get_enum_str() and get_enum_strs() record routines retrieve these strings for the operator. get_enum_str() gets the string corresponding to the value in VAL, and get_enum_strs() retrieves all the strings.

See Fields Common to All Record Types for more on the record name (NAME) and description (DESC) fields.

Field Summary Type DCT Default Read Write CA PP
NAME Record Name STRING [61] No Yes No No
DESC Descriptor STRING [41] Yes Yes Yes No
ZRST Zero String STRING [26] Yes Yes Yes Yes
ONST One String STRING [26] Yes Yes Yes Yes
TWST Two String STRING [26] Yes Yes Yes Yes
THST Three String STRING [26] Yes Yes Yes Yes
FRST Four String STRING [26] Yes Yes Yes Yes
FVST Five String STRING [26] Yes Yes Yes Yes
SXST Six String STRING [26] Yes Yes Yes Yes
SVST Seven String STRING [26] Yes Yes Yes Yes
EIST Eight String STRING [26] Yes Yes Yes Yes
NIST Nine String STRING [26] Yes Yes Yes Yes
TEST Ten String STRING [26] Yes Yes Yes Yes
ELST Eleven String STRING [26] Yes Yes Yes Yes
TVST Twelve String STRING [26] Yes Yes Yes Yes
TTST Thirteen String STRING [26] Yes Yes Yes Yes
FTST Fourteen String STRING [26] Yes Yes Yes Yes
FFST Fifteen String STRING [26] Yes Yes Yes Yes

Alarm Parameters

The possible alarm conditions for multi-bit binary outputs are the SCAN, READ, INVALID, and state alarms. The SCAN and READ alarms are called by the support modules and are not configurable by the user, as their severity is always MAJOR.

The IVOA field specifies an action to take from a number of possible choices when the INVALID alarm is triggered. The IVOV field contains a value to be written once the INVALID alarm has been triggered if Set output to IVOV has been chosen in the IVOA field. The severity of the INVALID alarm is not configurable by the user.

The state alarms are configured in the below severity fields. These fields have the usual possible values for severity fields: NO_ALARM, MINOR, and MAJOR.

The unknown state severity field (UNSV), if set to MINOR or MAJOR, triggers an alarm when the record support routine cannot find a matching value in the state value fields for VAL or when VAL is out of range.

The change of state severity field (COSV) triggers an alarm when the record's state changes, if set to MAJOR or MINOR.

The state severity (ZRSV-FFSV) fields, when set to MAJOR or MINOR, trigger an alarm when VAL equals the corresponding field.

See Invalid Output Action Fields for an explanation of the IVOA and IVOV fields. Alarm Fields lists the fields related to alarms that are common to all record types.

Field Summary Type DCT Default Read Write CA PP
UNSV Unknown State Sevr MENU menuAlarmSevr Yes Yes Yes Yes
COSV Change of State Sevr MENU menuAlarmSevr Yes Yes Yes Yes
IVOA INVALID outpt action MENU menuIvoa Yes Yes Yes No
IVOV INVALID output value USHORT Yes Yes Yes No
ZRSV State Zero Severity MENU menuAlarmSevr Yes Yes Yes Yes
ONSV State One Severity MENU menuAlarmSevr Yes Yes Yes Yes
TWSV State Two Severity MENU menuAlarmSevr Yes Yes Yes Yes
THSV State Three Severity MENU menuAlarmSevr Yes Yes Yes Yes
FRSV State Four Severity MENU menuAlarmSevr Yes Yes Yes Yes
FVSV State Five Severity MENU menuAlarmSevr Yes Yes Yes Yes
SXSV State Six Severity MENU menuAlarmSevr Yes Yes Yes Yes
SVSV State Seven Severity MENU menuAlarmSevr Yes Yes Yes Yes
EISV State Eight Severity MENU menuAlarmSevr Yes Yes Yes Yes
NISV State Nine Severity MENU menuAlarmSevr Yes Yes Yes Yes
TESV State Ten Severity MENU menuAlarmSevr Yes Yes Yes Yes
ELSV State Eleven Severity MENU menuAlarmSevr Yes Yes Yes Yes
TVSV State Twelve Severity MENU menuAlarmSevr Yes Yes Yes Yes
TTSV State Thirteen Sevr MENU menuAlarmSevr Yes Yes Yes Yes
FTSV State Fourteen Sevr MENU menuAlarmSevr Yes Yes Yes Yes
FFSV State Fifteen Sevr MENU menuAlarmSevr Yes Yes Yes Yes

Run-Time Parameters

These parameters are used by the run-time code for processing the multi-bit binary output.

MASK is used by device support routine to read the hardware register. Record support sets low order of MASK the number of bits specified in NOBT. Device support can shift this value.

The LALM field implements the change of state alarm severity by holding the value of VAL when the previous change of state alarm was issued.

MLST holds the value when the last monitor for value change was triggered.

SDEF is used by record support to save time if no states are defined; it is used for converting VAL to RVAL.

Field Summary Type DCT Default Read Write CA PP
NOBT Number of Bits USHORT Yes Yes No No
ORAW Prev Raw Value ULONG No Yes No No
MASK Hardware Mask ULONG No Yes No No
LALM Last Value Alarmed USHORT No Yes No No
MLST Last Value Monitored USHORT No Yes No No
SDEF States Defined SHORT No Yes No No

Simulation Mode Parameters

The following fields are used to operate the record in simulation mode.

If SIMM (fetched through SIML, if populated) is YES, the record is put in SIMS severity and the value is written through SIOL, without conversion. If SIMM is RAW, the value is converted and RVAL is written. SSCN sets a different SCAN mechanism to use in simulation mode. SDLY sets a delay (in sec) that is used for asynchronous simulation processing.

See Output Simulation Fields for more information on simulation mode and its fields.

Field Summary Type DCT Default Read Write CA PP
SIML Simulation Mode Link INLINK Yes Yes Yes No
SIMM Simulation Mode MENU menuSimm No Yes Yes No
SIOL Simulation Output Link OUTLINK Yes Yes Yes No
SIMS Simulation Mode Severity MENU menuAlarmSevr Yes Yes Yes No
SDLY Sim. Mode Async Delay DOUBLE Yes -1.0 Yes Yes No
SSCN Sim. Mode Scan MENU menuScan Yes 65535 Yes Yes No

Record Support

Record Support Routines

init_record

This routine initializes SIMM if SIML is a constant or creates a channel access link if SIML is PV_LINK. If SIOL is PV_LINK a channel access link is created.

This routine next checks to see that device support is available. The routine next checks to see if the device support write routine is defined. If either device support or the device support write routine does not exist, an error message is issued and processing is terminated.

If DOL is a constant, then VAL is initialized to its value and UDF is set to FALSE.

MASK is cleared and then the NOBT low order bits are set.

If device support includes init_record(), it is called.

init_common is then called to determine if any states are defined. If states are defined, SDEF is set to TRUE.

If device support returns success, VAL is then set from RVAL and UDF is set to FALSE.

process

See next section.

special

Computes SDEF when any of the fields ZRVL,...FFVL change value.

get_value

Fills in the values of struct valueDes so that they refer to VAL.

get_enum_str

Retrieves ASCII string corresponding to VAL.

get_enum_strs

Retrieves ASCII strings for ZRST,...FFST.

put_enum_str

Checks if string matches ZRST,...FFST and if it does, sets VAL.

Record Processing

Routine process implements the following algorithm:

  1. Check to see that the appropriate device support module exists. If it doesn't, an error message is issued and processing is terminated with the PACT field still set to TRUE. This ensures that processes will not longer be called for this record. Thus error storms will not occur.
  2. If PACT is FALSE
    • If DOL is DB_LINK and OMSL is CLOSED_LOOP
      • Get value from DOL
      • Set UDF to FALSE
      • Check for link alarm
    • If any state values are defined
      • If VAL > 15, then raise alarm and go to 4
      • Else using VAL as index set RVAL = one of ZRVL,...FFVL
    • Else set RVAL = VAL
    • Shift RVAL left SHFT bits
  3. Convert
    • If PACT is FALSE, compute RVAL
      • If VAL is 0,...,15, set RVAL from ZRVL,...,FFVL
      • If VAL out of range, set RVAL = undefined
    • Status = write_mbbo
  4. Check alarms. This routine checks to see if the new VAL causes the alarm status and severity to change. If so, NSEV, NSTA and LALM are set.
  5. Check severity and write the new value. See Output Simulation Fields and Invalid Output Action Fields for more information.
  6. If PACT has been changed to TRUE, the device support write output routine has started but has not completed writing the new value. In this case, the processing routine merely returns, leaving PACT TRUE.
  7. Check to see if monitors should be invoked.
    • Alarm monitors are invoked if the alarm status or severity has changed.
    • Archive and value change monitors are invoked if MLST is not equal to VAL.
    • Monitors for RVAL and RBV are checked whenever other monitors are invoked.
    • NSEV and NSTA are reset to 0.
  8. Scan forward link if necessary, set PACT FALSE, and return.

Device Support

Fields Of Interest To Device Support

Each mbbo record must have an associated set of device support routines. The primary responsibility of the device support routines is to obtain a new raw mbbo value whenever write_mbbo is called. The device support routines are primarily interested in the following fields:

Field Summary Type DCT Default Read Write CA PP
PACT Record active UCHAR No Yes No No
DPVT Device Private NOACCESS No No No No
NSEV New Alarm Severity MENU menuAlarmSevr No Yes No No
NSTA New Alarm Status MENU menuAlarmStat No Yes No No
NOBT Number of Bits USHORT Yes Yes No No
OUT Output Specification OUTLINK Yes Yes Yes No
RVAL Raw Value ULONG No Yes Yes Yes
RBV Readback Value ULONG No Yes No No
MASK Hardware Mask ULONG No Yes No No
SHFT Shift USHORT Yes Yes Yes No

Device Support Routines

Device support consists of the following routines:

long report(int level)

This optional routine is called by the IOC command dbior and is passed the report level that was requested by the user. It should print a report on the state of the device support to stdout. The level parameter may be used to output increasingly more detailed information at higher levels, or to select different types of information with different levels. Level zero should print no more than a small summary.

long init(int after)

This optional routine is called twice at IOC initialization time. The first call happens before any of the init_record() calls are made, with the integer parameter after set to 0. The second call happens after all of the init_record() calls have been made, with after set to 1.

init_record

init_record(precord)

This routine is optional. If provided, it is called by the record support's init_record() routine. If MASK is used, it should be shifted if necessary and SHFT given a value.

get_ioint_info

get_ioint_info(int cmd,struct dbCommon *precord,IOSCANPVT *ppvt)

This routine is called by the ioEventScan system each time the record is added or deleted from an I/O event scan list. cmd has the value (0,1) if the record is being (added to, deleted from) an I/O event list. It must be provided for any device type that can use the ioEvent scanner.

write_mbbo

write_mbbo(precord)

This routine must output a new value. It returns the following values:

  • 0: Success.
  • Other: Error.

Device Support For Soft Records

Soft Channel

The Soft Channel module writes the current value of VAL.

If the OUT link type is PV_LINK, then dbCaAddInlink is called by init_record().

write_mbbo() calls dbPutLink() to write the current value of VAL. See "Soft Output" for more information.

Raw Soft Channel

This module writes RVAL to the location specified in the output link. It returns a 0.