-
Notifications
You must be signed in to change notification settings - Fork 16
/
victron_em.py
102 lines (86 loc) · 3.41 KB
/
victron_em.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
import device
import mdns
import probe
from register import *
from victron_regs import *
import vreglink
class VE_Meter_A1B1(vreglink.VregLink, device.EnergyMeter):
vendor_id = 've'
vendor_name = 'Victron Energy'
productid = 0xa1b1
productname = 'Energy Meter VM-3P75CT'
vreglink_base = 0x4000
vreglink_size = 32
allowed_roles = None
age_limit_fast = 0
refresh_time = 20
def phase_regs(self, n):
base = 0x3040 + 8 * (n - 1)
power = 0x3082 + 4 * (n - 1)
return [
Reg_s16( base + 0, '/Ac/L%d/Voltage' % n, 100, '%.1f V'),
Reg_s16( base + 1, '/Ac/L%d/Current' % n, 100, '%.1f A'),
Reg_u32b(base + 2, '/Ac/L%d/Energy/Forward' % n, 100, '%.1f kWh',
invalid=0xffffffff),
Reg_u32b(base + 4, '/Ac/L%d/Energy/Reverse' % n, 100, '%.1f kWh',
invalid=0xffffffff),
Reg_s32b(power, '/Ac/L%d/Power' % n, 1, '%.1f W'),
]
def device_init(self):
self.info_regs = [
Reg_text( 0x1001, 8, '/Serial'),
VEReg_ver(0x1009, '/FirmwareVersion'),
Reg_u16( 0x100b, '/HardwareVersion'),
Reg_text( 0x2002, 32, '/CustomName', encoding='utf-8'),
]
self.data_regs = [
Reg_u16( 0x2000, onchange=self.pr_changed), # phase config
Reg_u16( 0x2001, onchange=self.pr_changed), # role
Reg_text(0x2002, 32, '/CustomName', encoding='utf-8',
write=self.set_name, onchange=self.name_changed),
]
phase_cfg = self.read_register(self.data_regs[0])
phases = [phase_cfg + 1] if phase_cfg < 3 else [1, 2, 3]
self.nr_phases = len(phases)
role_id = self.read_register(self.data_regs[1])
if role_id < len(self.role_names):
self.role = self.role_names[role_id]
ver = self.read_register(self.info_regs[1])
if ver < (0, 1, 3, 1):
self.log.info('Old firmware, data not available')
return
self.data_regs += [
Reg_u16( 0x3032, '/Ac/Frequency', 100, '%.1f Hz'),
Reg_s16( 0x3033, '/Ac/PENVoltage', 100, '%.1f V'),
Reg_u32b(0x3034, '/Ac/Energy/Forward', 100, '%.1f kWh',
invalid=0xffffffff),
Reg_u32b(0x3036, '/Ac/Energy/Reverse', 100, '%.1f kWh',
invalid=0xffffffff),
Reg_u16( 0x3038, '/ErrorCode'),
Reg_s32b(0x3080, '/Ac/Power', 1, '%.1f W'),
]
for n in phases:
self.data_regs += self.phase_regs(n)
if ver < (0, 1, 5, 255):
return
if self.role == 'pvinverter':
posreg = Reg_u16(0x2022, '/Position')
self.position = self.read_register(posreg)
self.data_regs.append(posreg)
def set_name(self, val):
self.vreglink_set(0x10c, bytes(val, encoding='utf-8'))
return True
def name_changed(self, reg):
self.dbus['/Devices/0/CustomName'] = reg.value
def pr_changed(self, reg):
self.sched_reinit()
models = {
VE_Meter_A1B1.productid: {
'model': 'VM-3P75CT',
'handler': VE_Meter_A1B1,
},
}
probe.add_handler(probe.ModelRegister(Reg_u16(0x1000), models,
methods=['udp'],
units=[1]))
mdns.add_service('_victron-energy-meter._udp')