Model Type

This unit model is formulated as a pass-through model form. See documentation for :ref:`pass-through Helper Methods<pt_methods>`.

Electricity Consumption

The constraint used to calculate energy consumption is described in the Additional Constraints section below. More details can be found in the unit model class.

Costing Method

Costing is calculated using the :py:meth:`~watertap.unit_models.zero_order.chemical_addition_zo.ChemicalAdditionZOData.cost_chemical_addition` method. For full details on costing, see documentation for the :ref:`zero-order costing package<zero_order_costing>`.

Additional Variables

Description Variable Name Units
Dosing rate of chemical chemical_dosage mg/l
Mass density of chemical solution solution_density kg/m^3
Mass fraction of chemical in solution ratio_in_solution dimensionless
Volumetric flow rate of chemical solution chemical_flow_vol m^3/s
Electricity consumption of unit electricity kW

Additional Constraints

Description Constraint Name
None chemical_flow_constraint
Constraint for electricity consumption based on pump flowrate. electricity_consumption