This unit model is formulated as a single-input, double-output model form. See documentation for single-input, double-output Helper Methods<sido_methods>
.
Electricity consumption is calculated using the pump_electricity helper function. See documentation for Helper Methods for Electricity Demand<electricity_methods>
.
This unit does not include costing.
Description | Variable Name | Units |
---|---|---|
Mass flow of gas extracted per mass flow of influent | gas_mass_influent_ratio | dimensionless |
Mass flow of hydrogen extracted | flow_mass_gas_extraction | kg/s |
Description | Constraint Name |
---|---|
Overall flow balance | mass_balance |
Gas extraction equation | mass_gas_extraction_equation |
pair: watertap.unit_models.zero_order.gas_sparged_membrane_zo;gas_sparged_membrane_zo
watertap.unit_models.zero_order.gas_sparged_membrane_zo
watertap.unit_models.zero_order.gas_sparged_membrane_zo