Skip to content

Latest commit

 

History

History
49 lines (36 loc) · 1.6 KB

File metadata and controls

49 lines (36 loc) · 1.6 KB

Membrane Aerated Biofilm Reactor (ZO)

Model Type

This unit model is formulated as a reactive single-inlet, double-outlet model form. See documentation for :ref:`reactive single-inlet, double-outlet Helper Methods<sidor_methods>`.

Electricity Consumption

Electricity consumption is calculated using the constant_intensity helper function. See documentation for :ref:`Helper Methods for Electricity Demand<electricity_methods>`.

Costing Method

Costing is calculated using the :py:meth:`~watertap.unit_models.zero_order.mabr_zo.MABRZOData.cost_mabr` method. For full details on costing, see documentation for the :ref:`zero-order costing package<zero_order_costing>`.

Additional Variables

Description Variable Name Units
Nitrogen removal rate per day nitrogen_removal_rate g/d/m^2
Sizing variable for effective reactor area reactor_area m^2
Air flow rate per area air_flow_rate m/h
Volumetric air flow rate air_flow_vol m^3/h

Additional Constraints

Description Constraint Name
Constraint for effective reactor area reactor_area_constraint
Constraint for air flow air_flow_constraint
.. index::
   pair: watertap.unit_models.zero_order.mabr_zo;mabr_zo

.. currentmodule:: watertap.unit_models.zero_order.mabr_zo

Class Documentation

.. automodule:: watertap.unit_models.zero_order.mabr_zo
    :members:
    :noindex: