This unit model is formulated as a single-input, double-output model form. See documentation for :ref:`single-input, double-output Helper Methods<sido_methods>`.
Electricity consumption is calculated using the constant_intensity helper function. See documentation for :ref:`Helper Methods for Electricity Demand<electricity_methods>`.
Costing is calculated using the :py:meth:`~watertap.unit_models.zero_order.membrane_evaporator_zo.MembraneEvaporatorData.cost_membrane_evaporator` method. For full details on costing, see documentation for the :ref:`zero-order costing package<zero_order_costing>`.
Description | Variable Name | Units |
---|---|---|
Water flux through membrane | water_flux | m/h |
Membrane area | membrane_area | m^2 |
Description | Constraint Name |
---|---|
Constraint for water flux. | wat_flux |
.. index:: pair: watertap.unit_models.zero_order.membrane_evaporator_zo;membrane_evaporator_zo
.. currentmodule:: watertap.unit_models.zero_order.membrane_evaporator_zo
.. automodule:: watertap.unit_models.zero_order.membrane_evaporator_zo :members: :noindex: