Ultraviolet Advanced Oxidation Process

.. index::
   pair: watertap.unit_models.uv_aop;uv_aop

.. currentmodule:: watertap.unit_models.uv_aop

Introduction

Ultraviolet (UV) light is widely used in the water industry to inactivate microorganisms by damaging their nucleic acid, which prevents the pathogen from replicating and causing infection (Wright et al, 2006). Some contaminants resistant to biodegradation, such as N-Nitrosodimethylamine (NDMA), are susceptible to UV disinfection. The high oxidizing capability of UV is often used prior to chemical disinfection to ensure high microbial quality water as well as significantly reducing the chemical dosage required.

Advanced oxidation processes (AOPs) are technologies involving the generation of highly reactive oxidative species, predominantly hydroxyl radicals (\text{HO} \cdot). Unlike conventional chemical oxidation processes, such as using chlorine, which are selective as to which compounds they can degrade, AOPs are able to completely convert organic compounds into carbon dioxide, water and mineral acids. In addition, AOPs are feasible for full-scale use to destroy organic compounds because they generate hydroxyl radicals at ambient temperature and atmospheric pressure. Typically, the commercially available UV AOPs for industrial water treatment are:

  1. UV light and hydrogen peroxide (\text{H}_2\text{O}_2)
  2. UV light and ozone (\text{O}_3)
  3. UV light, hydrogen peroxide (\text{H}_2\text{O}_2) and ozone (\text{O}_3)

UV AOPs can be modeled at several different levels, depending on the known kinetic pathways and the modeling objectives. In this work, a basic level kinetic model is presented with an assumption on pseudo-steady state approximation for the kinetic description of free radical species. A pseudo-first order rate constant is utilized to represent the overall degradation rate of contaminants. The users need to provide either UV dose and disinfection rate, or rate constant and exposure time that are can be acquired during UV validation tests. These measurements are then used to simulate the removal of contaminants during the UV AOP process.

This model also accounts for the energy demand for the disinfection process. The users need to provide Electrical Efficiency per Log Order Reduction (EE/O) to evaluate energy costs.

Ports

The model provides two ports (Pyomo notation in parentheses):

  • Inlet port (inlet)
  • Outlet port (outlet)

Sets

Description Symbol Indices
Time t [0]
Phases p ['Liq']
Components j ['H2O', 'NDMA', ...]

Degrees of Freedom and Variables

The UV system includes the state variables from the associated property package, and an outline of these variables are listed below:

Description Symbol Variable Name Index Units
Inlet temperature T temperature [t] \text{K}
Inlet pressure P_{in} pressure [t] \text{Pa}
Outlet pressure P_{out} pressure [t] \text{Pa}
Mass flowrate of components M_{p, j} flow_mass_phase_comp [t, p, j] \text{kg/s}
Inlet volumetric flowrate F_{in} flow_vol [t] \text{m}^3\text{/s}

NOTE: Variables for 'temperature', 'pressure', 'flow_mass_phase_comp', and 'flow_vol' come from the associated property package as state variables and are accessed via {port_name}.{state_var_name}

Aside from the inlet feed state variables (i.e., temperature, pressure, component mass flowrates), the UV model has at least an additional 5 degrees of freedom that the user must specify when the uv_dose_type configuration option is set to default UVDoseType.fixed and the has_aop configuration is set to default False. The table below gives an outline of these.

Description Symbol Variable Name Index Units
Inactivation rate coefficient k inactivation_rate [p, j] \text{m}^2\text{/J}
Overall pseudo-first order rate constant k_0 rate_constant [p, j] \text{s}^{-1}
Pseudo-first order rate constant for direct photolysis of component k_d photolysis_rate_constant [p, j] \text{s}^{-1}
Pseudo-first order rate constant for indirect photolysis of component k_i reaction_rate_constant [p, j] \text{s}^{-1}
UV dose D uv_dose None \text{J/}\text{m}^2
Average intensity of UV light I uv_intensity None \text{J/}\text{m}^2\text{/s}
Exposure time of UV light t exposure_time None \text{s}
Electricity demand of components with phase E_{p, j} electricity_demand_phase_comp [t, p, j] \text{W}
Electricity demand of components E_j electricity_demand_comp [t, j] \text{W}
Electricity demand E electricity_demand [t] \text{W}
Electricity efficiency per log order reduction (EE/O) EE/O_{p, j} electrical_efficiency_phase_comp [t, p, j] \text{J/}\text{m}^3
Lamp efficiency \eta lamp_efficiency None None
Users must provide values for and 'fix' certain variables to solve the model with DOF=0. Thus, users should fix
  • either 'inactivation_rate' or 'rate_constant',
  • two variables out of 'uv_dose', 'uv_intensity' and 'exposure_time',
  • either 'electricity_demand_phase_comp' or 'electrical_efficiency',
  • and 'lamp_efficiency'.

However, users may later unfix certain variables for optimization purposes.

NOTE: 'reaction_rate_constant' is fixed to 0 when 'has_aop' configuration is set to default 'False'

When setting the uv_dose_type configuration option to UVDoseType.calculated, there are 7 additional variables that must be fixed. This leads to a total of 12 degrees of freedom. Additional variables that must be fixed include:

Description Symbol Variable Name Index Units
UV transmittance UVT UVT None None
Coefficient A A A_coeff None None
Coefficient B B B_coeff None None
Coefficient C C C_coeff None None
Coefficient D D D_coeff None None
Relative lamp output \frac{S}{S_0} relative_lamp_output None None
Number of banks N_{bank} num_of_banks None None

When setting the has_aop configuration option to True, there are 2 additional variable that must be fixed. This leads to a total of 6 degrees of freedom. Additional variables that must be fixed include:

Description Symbol Variable Name Index Units
Second-order reaction rate constant k_{OH} second_order_reaction_rate_constant [p, j] \text{M}^{-1} \text{s}^{-1}
Steady-state concentration of hydrogen peroxide c_{\text{H}_2\text{O}_2} hydrogen_peroxide_conc None \text{M}
Users must provide values for and 'fix' certain variables to solve the model with DOF=0. Thus, users should fix
  • either 'photolysis_rate_constant' or 'reaction_rate_constant',
  • either 'second_order_reaction_rate_constant' or 'hydrogen_peroxide_conc'.

Equations and Relationships

if uv_dose_type and has_aop are set to default:

Description Equation
UV dose D = I \cdot t
Pseudo-first order rate constant k_0 = I \cdot k
Pseudo-first order rate constant k_0 = k_d + k_i
Solvent mass balance M_{\text{H2O},out} = M_{\text{H2O},in}
Solute mass balance M_{p, j, out} = M_{p, j, in} \cdot \exp(D \cdot k)
Electricity demand of each component with phase E_{p, j} = EE/O_{p, j} \cdot F_{in} \cdot \log_{10}(M_{p, j, in} / M_{p, j, out}) / \eta
Electricity demand of each component E_j = \max_p E_{p, j}
Electricity demand E = \max_j E_j

NOTE: 'reaction_rate_constant' is fixed to 0

if uv_dose_type is set to UVDoseType.calculated, there is one additional equation:

Description Equation
UV dose D = 10^A \cdot (-\log_{10}(UVT))^{(-B \cdot \log_{10}(UVT))} \cdot (\frac{S}{S_0} / F_{in})^C \cdot N_{bank}^D

if has_aop is set to True, there are one additional equation:

Description Equation
Reaction rate constant k_i = k_{OH} \cdot c_{\text{H}_2\text{O}_2}

Costing Method

Costing Method Variables

The following variables are constructed when applying the UV-AOP costing method in the watertap_costing_package:

Description Symbol Variable Name Units
UV reactor cost C_{cap,r} reactor_cost $/(\text{m}^3\text{/h})
UV lamps, sleeves, ballasts and sensors cost C_{cap,l} lamp_cost $/\text{kW}
Fraction of UV replaced per year f_l factor_lamp_replacement \text{y}^{-1}

Capital Cost Calculations

Capital costs are determined by the summation of reactor and lamp costing terms. The reactor costing term is determined based on inlet flow rate. The lamp costing term is determined based on electricity demand.

Description Equation
Total capital cost C_{cap,tot} = C_{cap,r} \cdot F_{in} + C_{cap,l} \cdot E

NOTE: the default costing calculation is evaluated based on a UV system with low-pressure lamps. Users can provide corresponding costing variables for a specific UV system with other lamp types

Operating Cost Calculations

Operating costs are calculated as the cost to replace lamps, sleeves, ballasts and sensors in a UV system.

Description Equation
Fixed operating cost C_{op} = f_l \cdot C_{cap,l} \cdot E

Class Documentation

References

Wright, H., Gaithuma, D., Greene, D., Aieta, M. (2006) Integration of validation, design, and operation provides optimal implementation of UV disinfection. American Water Works Association, 98, 81-92