Skip to content

Latest commit

 

History

History
50 lines (37 loc) · 1.75 KB

File metadata and controls

50 lines (37 loc) · 1.75 KB

Filter Press (ZO)

Model Type

This unit model is formulated as a single-input, double-output model form. See documentation for :ref:`single-input, double-output Helper Methods<sido_methods>`.

Electricity Consumption

The constraint used to calculate energy consumption is described in the Additional Constraints section below. More details can be found in the unit model class.

Costing Method

Costing is calculated using the :py:meth:`~watertap.unit_models.zero_order.filter_press_zo.FilterPressZOData.cost_filter_press` method. For full details on costing, see documentation for the :ref:`zero-order costing package<zero_order_costing>`.

Additional Variables

Description Variable Name Units
Hours per day of filter press operation hours_per_day_operation h/d
Filter press cycle time cycle_time h
Parameter A for electricity calculation electricity_a_parameter kWh/a/ft^3
Parameter B for electricity calculation electricity_b_parameter dimensionless
Filter press capacity filter_press_capacity ft^3
Filter press power electricity kW

Additional Constraints

Description Constraint Name
Filter press capacity constraint fp_capacity
Filter press electricity constraint fp_electricity
.. index::
   pair: watertap.unit_models.zero_order.filter_press_zo;filter_press_zo

.. currentmodule:: watertap.unit_models.zero_order.filter_press_zo

Class Documentation

.. automodule:: watertap.unit_models.zero_order.filter_press_zo
    :members:
    :noindex: